Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
2-CHANNEL GDS:    10 Items found.
(2127)

GDS  C2-00-090-00/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. For Electrochemical/Toxic applications. Includes 1 x 4-20 mA input channel, 2nd channel optional.



 
(355)

GDS  C2-20-010-04/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Oxygen (O2) sensor with range 0-25% Vol. with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(365)

GDS  C2-20-011-06/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Carbon Monixide (CO) sensor with range 0-100 to 0-9999 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(368)

GDS  C2-20-014-19/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Hydrogen (H2) sensor with range 0-1% or 0-4% vol. with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(369)

GDS  C2-20-015-04/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Hydrogen Sulfide (H2S) sensor with range 0-25 to 0-5000 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(373)

GDS  C2-20-019-05/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Sulfur Dioxide (SO2) sensor with range 0-50 to 0-500 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(376)

GDS  C2-20-029-05/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Nitrogen Dioxide (NO2) sensor with range 0-20 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(366)

GDS  C2-22-012-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Chlorine (Cl2) sensor with range 0-5 to 0-50 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(374)

GDS  C2-22-020-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Ammonia (NH3) sensor with range 0-50 to 0-1000 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(5814)

GDS  GMII-00-000-00/00-000-00/0-0

GDS GASMAX II 3-Wire 2-channel Gas Detector Controller, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU and 2-20 mA/Bridge inputs.



 


Cookie Notice