Gasdetectorsusa.com: Gas Detectors (explosion-proof) - All
Honeywell Analytics, Prosense, Felix Instruments, Solo, Ion Science, Spectrex, Intec Controls, E2S, RC Systems, ESP Safety, CoolAir, Portagas, Macurco, MEDC, CO2 Meter, GDS Corp, mPower, KwikDraw Uniphos, ACD
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
GAS DETECTORS (EXPLOSION-PROOF) > all :    382 Items found.
100-0008-SS
(4725)

ESP SAFETY  100-0008-SS

ESP Safety Vector 2-channel gas detector controller . Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. It can be configured with one or two optional sensors, including: Chlorine (Cl2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Hydrogen (H2), Hydrogen Sulfide (H2S), Methane (CH4), Ammonia (NH3), Oxygen (O2), Propane (C3H8) and Sulfur Dioxide (SO2).

Configure

$1,050.30 
PQN-6234-1/2
(6952)

PROSENSE  PQN-6234-1/2

Prosense PQN-6234 Gas Detector with Electrochemical sensor for Etylene Oxide (ETO) with ranges 0-20ppm or 0-100ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
PQN-4834-1/2
(6920)

PROSENSE  PQN-4834-1/2

Prosense PQN-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
PQN-6634-1/2
(6955)

PROSENSE  PQN-6634-1/2

Prosense PQN-6634 Gas Detector with Electrochemical sensor for Sulfide Dioxide (SO2) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
PQN-6834-1/2
(6957)

PROSENSE  PQN-6834-1/2

Prosense PQN-6834 Gas Detector with Electrochemical sensor for Nitrogen Dioxide (NO2) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
PQN-6934-1/2
(6958)

PROSENSE  PQN-6934-1/2

Prosense PQN-6934 Gas Detector with Electrochemical sensor for Chlorine (Cl2) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
PQD-7231-1/2
(6748)

PROSENSE  PQD-7231-1/2

Prosense PQD-7231/9131 Gas Detector with Semiconductor sensor for Refrigerant (Optional: R-32, R-1234yf, R-1234ze, R-454B, R404A, R-290, R-410A, R-22, R-407C, R-134A, R-410A, R-404A) with range 0-2000ppm/0-10,000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,081.08 
GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$1,110.65 
PQD-9031-1/2
(6759)

PROSENSE  PQD-9031-1/2

Prosense PQD-9031 Gas Detector with Semiconductor sensor for Air Quality (Optional: detect Hydrogen, Carbon monoxide, Ethanol, Ammonia, Formaldehyde, Acetaldehyde, Toluene, Xylene, Benzene, Acetic acid, Hydrogen sulfide, Methyl mercaptan, Trimethylamine) with range 0-30ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
PQD-9233-1/2
(7138)

PROSENSE  PQD-9233-1/2

Prosense PQD-9233 Gas Detector with Infrared sensor for R4448A 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
PQD-3033-1/2
(6719)

PROSENSE  PQD-3033-1/2

Prosense PQD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
PQN-8434-1/2
(6967)

PROSENSE  PQN-8434-1/2

Prosense PQN-8434 Gas Detector with Electrochemical sensor for Phospine (PH3) with range 0-10ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,132.56 
2106B1405
(1453)

HONEYWELL  2106B1405

Honeywell Sieger Sensepoint Gas Detector Transmitter for Carbon Monoxide (CO) (0-100 to 0-500) ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
2106B1430
(1468)

HONEYWELL  2106B1430

Honeywell Sieger Sensepoint Gas Detector Transmitter for Oxygen (O2) 25% V/V with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
2106B1422
(1467)

HONEYWELL  2106B1422

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitrogen Dioxide (NO2) 0-10 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
2106B1400
(1451)

HONEYWELL  2106B1400

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen Sulfide (H2S) (0-20 ppm to 0-100 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
2106B1420
(1465)

HONEYWELL  2106B1420

Honeywell Sieger Sensepoint Gas Detector Transmitter for Sulfur Dioxide (SO2) (0-15 to 0-50 ppm) ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
2106B1418
(1464)

HONEYWELL  2106B1418

Honeywell Sieger Sensepoint Gas Detector Transmitter for Nitric Oxide (NO) 0-100 ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
P-8234
(6792)

PROSENSE  P-8234

Prosense P-8234 Gas Detector with Electrochemical sensor for Ozone (O3) with range 0-1ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
PQD-6734-1/2
(6744)

PROSENSE  PQD-6734-1/2

Prosense PQD-6734 Gas Detector with Electrochemical sensor for Nitric Oxide (NO) with range 0-250ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
Page: 1 | 2 | 3 | 4 | *5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.