Intec Spc3-1112-200us | Carbon Monoxide | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

INTEC   SPC3-1112-200US

INTEC SPC3-1112-200US
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Intec Controls PolyGard SPC3-1112 Sigle-Point Gas Detector for Carbon Monoxide (CO) 0-200 to 0-300 ppm adjustable, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified. *** Phased Out ***

Inquiry

APPLICATION

To detect and control levels of carbon monoxide (CO) and other gases in a wide variety of commercial and industrial applications such as Carbon Monoxide level in parking structures, engine repair shops, equipment rooms and ventilation systems, etc. The controller can communicate with any compatible electronic analog control, DDC/PLC control or automation system via binary and/or analog output signal.

FEATURES
  • Continuous monitoring
  • One (1) built-in CO electrochemical sensor
  • Easy plug-in sensor
  • One (1) remote analog input, 4-20 mA
  • One (1) digital input
  • Two (2) relay outputs:
    Four stage control
    Fail-safe assignable
  • One (1) analog output, (0)4-20 mA / (0)2-10 VDC - Selectable for low, high, or averaging
  • One (1) 24 VDC switched output
  • Liquid Crystal Display (LCD)
  • LED status indicators
  • Accepts toxic or combustible gas, refrigerant, temperature or humidity secondary remote sensor input
  • Built-in horn
  • Keypad user interface
  • Simple menu-driven programming
  • Modular technology
  • Overload & short-circuit protected
  • NEMA 4X enclosure
  • Easy maintenance

Specifications
Electric
Power supply 24 VAC/VDC, -20%/+15% 50/60 Hz, reverse polarity protected
Power consumption 5 VA (0.2 A) w/ (1) remote sensor connected
Sensor Performance
Gas detected Carbon monoxide (CO)
Sensor element Electrochemical, diffusion
Range Span field adjustable from 0-200 to 0-300 ppm via calibration, 0-250 ppm factory set
Resolution ± 3.0 ppm of reading
Repeatability ± 3.0 % of reading
Long term output drift < 0.4% signal loss/month
Response time t90 < 50 sec.
Sensor life expectancy 3-5 years, normal operating environment
Sensor coverage 5,000 sq. ft., max 10,000 sq. ft. (465 m 2 , max 930 m 2 ), under “ideal conditions”
Installation Location
Mounting height 5 to 6 ft. (1.5-1.8 m) above floor
Type of Control
General Four-stage (S1 to S4) control, assignable up to two (2) binary/ relay, horn/audible alarm, and 24 VDC / 50 mA switched outputs, i.e. low-high stage for relay output, horn / audible alarm and switched 24 VDC at any stage for remote alarming
Analog input One (1) 4-20 mA, for additional remote sensor, load < 55 mA / 200 Ω, reverse polarity protected
Analog reading Current and mean (average) value
Stage level / setpoint Field adjustable over full range, four (4) stages (S1 to S4) per analog input, assignable to current or mean (average) value
- hysteresis/ switching differential Selectable for each sensor point
Digital input One (1); can be assigned to any relay (R1, R2)
- application Remote audio/visual alarm reset or override function
Type of Control (cont...)
Relay outputs (R1, R2) w/ status LEDs (1) SPDT (R1), and (1) SPST-NC or SPST-NO (R2), jumper selectable
Contact rating
-each stage level (S1-S4)
-sensor fail-safe
30 VAC/VDC, 0.5 A, max.
Assignable to any relay
Assignable to any stage level
Time delay switching Selectable for make and brake of each sensor point (SP1 to SP2) 0‐9,999 seconds
Analog output One (1), (0)4‐20 mA, load < 500 Ω;(0)2-10 VDC, load > 50K Ω; jumper selectable; polarity protected, assignable to low, high or averaging of sensor inputs
VDC switched output One (1) 24 VDC, 50 mA max
Audible alarm 83 db @ unit, enabled or disabled, selectable; assignable to stage level S1, S2, S3 or S4
Alarm acknowledgment Menu-driven and system reset function for latched relays
User Interface
Keypad type Refer to illustration “Keypad User Interface”
Touch buttons Four (4)
Status LED’s Four (4), for system on, stage status, and failure
Digital display Liquid Crystal Display (LCD), two lines, 16 characters per line, 1 digit resolution
-unit display Menu selectable, per sensor; ppm, %v/v, %LEL, °F or %RH
Environmental
Permissible ambient
-working temperature 14°F to 122°F (-10°C to 50°C)
-storage temperature 23°F to 86°F (-5°C to 30°C)
-humidity 15 to 95% RH, non-condensing
-working pressure Atmospheric ± 10%
Physical
Enclosure (panel)
-material Polycarbonate, UL 94-HB, fire-retardant
-conformity UL 50 standards
-color Light gray
-protection NEMA 4X (IP65)
-installation Wall (surface) mounted, or single gang electrical box
Dimensions (H x W x D) 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)
Cable entry 3 holes for 1/2 in. conduit for wall (surface) mounting and 1 hole on back side of base plate for single gang electrical box mounting
Wire connection Terminal blocks, screw type for lead wire
Wire size Min. 24 AWG (0.25 mm 2 )
Max 14 AWG (2.5 mm 2 )
Wire distance Max. loop resistance 450 Ω (= wire distance plus controller input resistance)
Weight 0.6 lb. (0.3 kg)
Approvals / Listings
-unit rating NRTL Perf Tested & Certified
Conforms to STD ANSI/UL 2075
City of Los Angeles
CE
VDI 2053, C-No. 418791
EMV-Compliance 2004/108/EWG
Low voltage directive 73/23/EWG
-relays (R1-R2) UL Recognized, E41515
CSA, C22.2 No. 0, No. 14 (File No. LR31928)
-enclosure UL Listed, E208470
CSA Certified, E208470
Warranty Two years material and workmanship, 12 months normal exposure for sensor element
> CARBON MONOXIDE :    37 Items found.
CM-E1
(638)

MACURCO  CM-E1

Macurco CM-E1 Carbon Monoxide gas detector for residential and commercial office environment. Flush or surface mount options, alarm and trouble relays, and 85 dB buzzer. 9-32 VDC input. NFPA 720-2009 and UL 2075 listed. CSFM Approved.



$66.15 
M015-0001-000
(6333)

MPOWER  M015-0001-000

mPower UNI 321 Disposable Single Gas Detector for detection of Carbon Monoxide (CO) 1-500ppm. Up to 36 months of live. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$108.80 
BWC2-M
(4265)

BW  BWC2-M

BW Clip portable gas detector 2 year maintenance free for Carbon Monoxide CO. Low alarm set between 25ppm and 50 ppm, High alarm set between 50ppm and 200 ppm. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

M001-0023-000
(5994)

MPOWER  M001-0023-000

mPower UNI MP100 Portable Single Gas Detector for detection of Carbon Monoxide (CO) 0-500ppm to 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$134.40 
PPS+-CO
(6813)

PROSENSE  PPS+-CO

Prosense PPS+-CO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm, 0-500ppm or 0-1000ppm. ABS Plastic housing. Modbus RS485 RTU output. IP54. For Parking Garages and Tunnels.

Configure

$214.50 
PPS-RCO
(6811)

PROSENSE  PPS-RCO

Prosense PPS-RCO Addressable Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300ppm. ABS Plastic housing. Relay outputs. IP54. For Parking Garages and Tunnels.



$214.50 
TX1-1
(5965)

INDUSTRIAL SCIENTIFIC  TX1-1

Industrial Scientific Tango TX1 Gas Detector for Carbon Monoxide (CO) 1-1000 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

BWC2R-M
(5149)

BW  BWC2R-M

BW Clip Real Time portable gas detector with 2 year maintenance free for Carbon Monoxide (CO). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWC3R-M
(5153)

BW  BWC3R-M

BW Clip Real Time portable gas detector with 3 year maintenance free for Carbon Monoxide (CO). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

LC-1112-A-000-1
(2913)

INTEC  LC-1112-A-000-1

Intec Controls PolyGard LC-1112 V3 Analog Gas Transmitter for Carbon Monoxide (CO) 0-150 / 0-200 / 0-250 / 0-300 ppm. 1 4-20mA & 2-10V analog output. Wall mounted. NEMA 4X Enclosure. UL Listed and CSA Certified.

Configure

$327.00 
BWS1-ML-Y
(6383)

BW  BWS1-ML-Y

BW Solo Serviceable Single-gas Detector for Carbon Monoxide (CO) 0-2000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-4424
(6802)

PROSENSE  PC3-4424

Prosense PC3-4424 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with range 0-300 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$463.32 
CM-6
(637)

MACURCO  CM-6

MACURCO CM-6 low voltage gas detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1. Optional LADBS approval.

Configure

$481.90 
CM-12
(3415)

MACURCO  CM-12

MACURCO CM-12 line voltage Gas Detector, controller and transducer for Carbon Monoxide (CO) 0-200 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$494.01 
P-4434
(6777)

PROSENSE  P-4434

Prosense P-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm to 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$540.54 
364-455-01-365-796-110100
(6150)

DELPHIAN  364-455-01-365-796-110100

Delphian GazTell Fixed Point Electrochemical Gas Detector for Carbon Monoxide (CO) 0-100, 0-300 or 0-1000 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

SPSTAXC1
(1477)

HONEYWELL  SPSTAXC1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Carbon Monoxide (CO) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-200 ppm, 0-500 ppm)

Configure

$719.15 
PQN-4434-1/2
(6949)

PROSENSE  PQN-4434-1/2

Prosense PQN-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm, 0-500ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
OI-6000-EC-CO-X-R_-DC-C
(6832)

OTIS  OI-6000-EC-CO-X-R-DC-C

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Carbon Monoxide (CO) 0-1000ppm. Non explosion proof. Wired power (3-Wire) (12 to 35 VDC) with 4-20 mA analog, RS-485 Modbus and 2 relay outputs. 3 Push-Button Interface. IP 66/67. Optional radio. UL Approved.

PQD-4434-1/2
(6738)

PROSENSE  PQD-4434-1/2

Prosense PQD-4434 Gas Detector with Electrochemical sensor for Carbon Monoxide (CO) with ranges 0-300ppm, 0-500ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2 and HART. IP65, Optional IP66 Adaptor.

Configure

$875.16 
OI-6000-EC-CO-X-X-O
(6835)

OTIS  OI-6000-EC-CO-X-X-O

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Carbon Monoxide (CO) 0-1000ppm. Explosion Proof Wired power (3-Wire). (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. 3 Push-Button Interface. IP 66/67. Optional alarm relays and Radio. CSA Approved for Class I Div 1. ATEX Zone 1 and IECEx Certified.

GG-CO-200
(2963)

CALIBRATION TECHNOLOGIES  GG-CO-200

CTI GasGuard CO Carbon Monoxide Electrochemical Sensor (0-200 ppm) for gas leak detection in food processing areas, warehousestank rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,088.34 
2106B1405
(1453)

HONEYWELL  2106B1405

Honeywell Sieger Sensepoint Gas Detector Transmitter for Carbon Monoxide (CO) (0-100 to 0-500) ppm with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
1100ALD-109011/0100P-L0
(6909)

RC SYSTEMS  1100ALD-109011/0100P-L0

RC Systems SenSmart 1100 gas detector for Carbon Monoxide (CO) 0-100ppm to 0-5000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
GG-CO-200-EXP
(5976)

CALIBRATION TECHNOLOGIES  GG-CO-200-EXP

CTI GG-CO-EXP Explosion Proof Electrochemical Gas Sensor for Carbon Monoxide (CO) 0-200 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,341.51 
100-0008-SS/100-0015-CO
(4751)

ESP SAFETY  100-0008-SS/100-0015-CO

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Carbon Monoxide (CO) 0-100, 0-500 or 0-1000ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
SPXCDULNCX
(664)

HONEYWELL  SPXCDULNCX

Honeywell XCD Sensepoint Gas Detector, Carbon Monoxide (CO) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for carbon monoxide (CO) gas hazards both indoors and outdoors. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 100 to 1,000ppm. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,442.71 
S3KUL2-XNXXSC1SS
(686)

HONEYWELL  S3KUL2-XNXXSC1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring CARBON MONOXIDE (CO) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-300ppm, user adjustable (100 to 999ppm, 100ppm increments) Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,497.56 
41001AL-0-1011/0050P/L0
(7159)

RC SYSTEMS  41001AL-0-1011/0050P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Carbon Monoxide (CO) 0-50 to 0-5000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
961-440026-100G
(2131)

DETCON  961-440026-100G

Detcon DM-100-CO Electrochemical Carbon Monoxide (CO) 0-100ppm SensorAssembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

51001AL-0-1011/0050P/L0
(7124)

RC SYSTEMS  51001AL-0-1011/0050P/L0

RC Systems SenSmart 5100 3-wire gas detector for Carbon Monoxide (CO) 0-50 to 0-5000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
967-444490-0100
(6074)

DETCON  967-444490-0100

Detcon DM-700-CO Electrochemical Smart Carbon Monoxide (CO) 0-100 ppm/0-200 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNC2
(5096)

HONEYWELL  SPXCDULNC2

Honeywell Sensepoint XCD RTD Gas Detector for Carbon Monoxide (CO) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 200 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
2100AL-0-9011/0100P/L0
(117)

RC SYSTEMS  2100AL-0-9011/0100P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Carbon Monoxide (CO) 0-100ppm to 0-5000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
31001AL-0-9011/0100P/L0
(5780)

RC SYSTEMS  31001AL-0-9011/0100P/L0

RC Systems SenSmart 3100 3 wire gas detector for Carbon Monoxide (CO) 0-100ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
XNXUTAENNNNN-XNXXSC1SS
(836)

HONEYWELL  XNXUTAENNNNN-XNXXSC1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Carbon Monoxide (CO) 0-300ppm, user adjustable (100 to 999ppm, 100ppm increments) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$1,969.63 
6100AL1-0-1011/0050P
(7002)

RC SYSTEMS  6100AL1-0-1011/0050P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Carbon Monoxide (CO) 0-50 to 0-5000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 