NOTIFIER   HWL-LF

NOTIFIER HWL-LF
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Notifier HRL-LF or HWL-LF Low frequency wall sounder (520 Hz). Plastic housing. Includes universal mounting plate. NFPA compliance. UL Listed.

HWL-LF   
Please Email us your request for quote   

Housing Color

 4 Weeks  ]
2 Variants of base SKU
General

L-Series audible visible notification products have features to maximize profits with lower current draw and modern aesthetics.

The L-Series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, listed for wall and ceiling mounting, L-Series Low Frequency can meet virtually any application requirement.

To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed.

Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, 24 volt operation, and a rotary switch for 520 Hz low frequency sounder tones.

Features
  • 520 Hz ± 10% square wave tone, NFPA compliance
  • Full candela range plus High/Low tone options to optimize current draw for a wide variety of applications
  • Compact, standard, and round ceiling options
  • Rotary switch for High and Low, Temp 3 and Temp4 settings
  • Plug-in design with minimal intrusion into the back box
  • Mounting plate shorting spring checks wiring continuity before device installation
  • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices, and provides a direct replacement for HW/R-LF and P2R/WH-LF
  • Compatible with MDL3 sync module
  • Sounders listed for ceiling and wall mounting
  • Updated modern aesthetics
Agency Listings and Approvals

These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL Listed: S4011
  • FM Approved: PR452768
  • CSFM: Horns only: 7135-1653:0516
    Horn/Strobes: 7125-1653:0517
Architects/Engineers Specifications

L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard 4 × 4 × 1.5-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 1 7 /8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit. Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit (0°C to 49°C) from a regulated DC or full-wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads “low frequency sounder”.

LOW FREQUENCY SOUNDER

The low frequency sounder shall be a System Sensor L-Series Model listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•Circuit. MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 24 volts (includes fire alarm panels with built in sync). When used with the Sync•Circuit Module MDL3, 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three or temporal four pattern, non-temporal (continuous) pattern and coded supply within the frequency range of 520Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or noncoded power supply with high and low volume settings.

Physical/Electrical Specifications
Standard Operating Temperature32°F to 120°F (0°C to 49°C)
Humidity Range10 to 93% non-condensing
Frequency Range520 Hz ± 10%
Nominal Voltage Low Frequency SounderRegulated 24 DC/ FWR 1
Nominal Voltage Range Low Frequency Sounder StrobeRegulated 24 VDC/FWR 1
Operating Voltage Range16 to 33 V (24 V nominal)
Operating Voltage Range MDL3 Sync Module16.5 to 33 V (24 V nominal)
Input Terminal Wire Gauge12 to 18 AWG
DIMENSIONS
Standard Wall Sounder Dimensions5.6" L × 4.7" W × 1.5" D (142 mm L × 119 mm W × 38 mm D)

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
NFS-320
(2039)

NOTIFIER  NFS-320

NOTIFIER by Honeywell ONYX Series NFS-320 Intelligent Addressable Fire Alarm Control Panel. Certified for seismic and marine applications. Supports up to 159 detectors and 159 modules. Standard 80-character display and 6A power supply. Built-in Alarm, Trouble, Security and Supervisory relays, FlashScan network prototol. *** UNPREDICTABLE LEAD TIME ****

> NOTIFIER :    37 Items found.
B300-6
(7063)

NOTIFIER  B300-6

Notifier B300-6 Standard 6” Intelligent Base

SMB500-WH
(4022)

NOTIFIER  SMB500-WH

Notifier System Sensor Surface Mount Box



 
SB-10
(6935)

NOTIFIER  SB-10

Notifier SB-10 (Metal) or SB-I/O (Plastic) Surface Backbox for Notifier NBG-10 or NBG-12 pull stations.

B501-WH
(7067)

NOTIFIER  B501-WH

Notifier B501 4” standard European flangeless mounting base. UL/ULC listed.

SPCWL
(7068)

NOTIFIER  SPCWL

Notifier SPCWL Indoor Selectable-Output Speaker for Ceiling Applications (520 Hz). 12- or 24-volt operation. UL, ULC, FM and CSFM approved.



 
FMM-1
(3695)

NOTIFIER  FMM-1

Notifier FMM-1/FMM-101 Series Monitor Module for supervised dry-contact input devices or monitor and power two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.

B200S-WH
(6928)

NOTIFIER  B200S-WH

Notifier B200S-WH Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. Only compatible with the NFS-320, NFS2-640 and NFS2-3030 operating version with version 15.0 or higher panel firmware.



 
FCM-1
(3236)

NOTIFIER  FCM-1

Notifier FCM-1 Series Addressable Control Module for Notification Appliances (horns, strobes, speakers, etc). Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
FRM-1
(3694)

NOTIFIER  FRM-1

Notifier FRM-1 Series Relay Module for activation of auxiliary devices (fans, dampers, etc). Two-wire SLC loop. Two Form-C dry contacts. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and FDNY Approved.



 
B210LPBP
(4141)

NOTIFIER  B210LPBP

Notifier B210LPBP Flanged Mounting Intelligent Base (10 Pack)



 
FDM-1
(6597)

NOTIFIER  FDM-1

Notifier FDM-1 Series Monitor Module to supervise, monitor and power Style B dry-contact input devices with two-wire circuits. Two-wire SLC loop. High noise immunity. 15 to 32 VDC. UL, FM, CSFM, MEA and US Coast Guard Approved.



 
B200S-LF-WH
(7066)

NOTIFIER  B200S-LF-WH

Notifier BS200S-LF Low Frequency Intelligent, programmable sounder base (520 Hz). Meest NFPA 72.

FCM-1-REL
(4143)

NOTIFIER  FCM-1-REL

Notifier FCM-1-REL(A) Series Releasing Control Module for fire suppresion releasing applications. Reports the panel status as NORMAL, OPEN or SHORT CIRCUIT. Analog communications. FlashScan operation. 15 to 32 VDC. UL, FM and CSFM Approved.



 
BAT-12180-BP
(4140)

NOTIFIER  BAT-12180-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 18 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
PF24V
(3237)

NOTIFIER  PF24V

Notifier PF24V ExitPoint Directional Sounder with Voice Messaging designed for open areas, corridors or stairs. Reduces evacuation times up to 75%. 24VDC. UL, FM, CSFM and MEA Approved.



 
BAT-1270-BP
(6944)

NOTIFIER  BAT-1270-BP

Notifier BAT-1270-BP rechargeable battery. 12VDC. 7 AH. 5-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12260-BP
(6941)

NOTIFIER  BAT-12260-BP

Notifier BAT-12260-BP rechargeable battery. 12VDC. 26 AH. 2-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-12550
(6943)

NOTIFIER  BAT-12550

Notifier BAT-12550 rechargeable battery. 12VDC. 55 AH. Overcharge protected. ABS high-impact case.



 
ISO-6
(6934)

NOTIFIER  ISO-6

Notifier ISO-6 Six Fault Isolator Module for Notifier Fire Alarm Control Panels (FACPs). Powered by SLC loop. Class B isolator circuits. UL, FM, CSFM Approved.



 
LDM-32
(6870)

NOTIFIER  LDM-32

Notifier LDM-32 Lamp Driver Module for annunciation and control of NOTIFIER Intelligent Fire Alarm Control Panels. Up to 32 alarm indications. 24 VDC. EIA-485 interface. UL, ULC, MEA, CSFM and FM Listed.



 
BAT-12120-BP
(6940)

NOTIFIER  BAT-12120-BP

Notifier BAT-12180-BP rechargeable battery. 12VDC. 12 AH. 4-unit bulk pack, Overcharge protected. ABS high-impact case.



 
BAT-1250-BP
(6942)

NOTIFIER  BAT-1250-BP

Notifier BAT-1250-BP rechargeable battery. 12VDC. 5 AH. 10-unit bulk pack, Overcharge protected. ABS high-impact case.



 
XP6-R
(6930)

NOTIFIER  XP6-R

Notifier by Honeywell XP6-R(A) Six Relay Control Module with Form-C Relays. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan® or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP6-C
(5122)

NOTIFIER  XP6-C

Notifier XP6-C Six Circuit Supervised Control Module for horns, strobes or bells that require an external power supply. Short-circuit-protection. Removable 12 AWG to 18 AWG plug-in terminal blocks. FlashScan® or CLIP operation. UL, MEA, FM and CSFM Approved.



 
XP10-M
(3724)

NOTIFIER  XP10-M

Notifier XP10-M Ten Input Monitor Module for intelligent alarm systems. Up to 10 addresable Class B or 5 addressable Class A devices. SLC inputs. Green LED indicators. Flexible mounting options. FlashScan® or CLIP operation. UL Listed. CSFM, FM, MEA and MSTM approved.



 
PSE-6
(6924)

NOTIFIER  PSE-6

Notifier PSE-6 (6 amp) or PSE-10 (10 amp) 24 VDC Remote Power Supply Expander with battery charger for 12 or 24 volt alarm control panels (FACP). Up to 7 outputs. UL, ULC, CSFM and FM listed.

APS2-6R
(6938)

NOTIFIER  APS2-6R

Notifier APS2-6R 6.0 Amp Auxiliary Power Supply for the Onyx Series control panels. 150 watt. 24 VDC. SLC circuit. UL, FM and CSFM listed.

BAT-121000
(6939)

NOTIFIER  BAT-121000

Notifier BAT-121000 rechargeable battery. 12VDC. 100 AH. Overcharge protected. ABS high-impact case.



 
NCM-F
(3507)

NOTIFIER  NCM-F

Notifier NCM-F or NCM-W network communication module for NOTIFIER Intelligent Fire Alarm Control Panels and Annunciators. Fiber optic or twisted-pair wire connection. 24 VDC.

HPFF12
(6600)

NOTIFIER  HPFF12

Notifier HPFF12(E) 12 Amp and 24 Volt Power Supply to extend the power of existing Notification Appliance Circuits (NACs) or provide power for auxiliary devices. 4 NAC and 1 aux outputs. 8 status LEDs. UL, CSFM and FM listed.

KDM-R2
(6932)

NOTIFIER  KDM-R2

Notifier KDM-R2 Keyboard Display Module for CPU2-640. 80 character display and QWERTY programming keypad included.



 
ACPS-610
(6936)

NOTIFIER  ACPS-610

Notifier ACPS-610 Addressable Charger/Power Supply. Provides 6 amps of shared power to four outputs or 10 amps as an external battery charger. SLC circuit. UL, ULC, CSFM and FM listed.

AMPS-24
(6937)

NOTIFIER  AMPS-24

Notifier AMPS-24 Addressable Power Supply for NFS-3030, NFS2-3030 and NCA-2. Charges 7 AH to 200 AH batteries. SLC circuit. UL, ULC, CSFM and FM listed.

LEM-320
(6872)

NOTIFIER  LEM-320

Notifier LEM-320 Loop Expander Module for NOTIFIER’s ONYX® Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
LCM-320
(6871)

NOTIFIER  LCM-320

Notifier LCM-320 Loop Control Module for NOTIFIER’s ONYX® Series of FireAlarm Control Panels (FACPs) with Signaling Line Circuits (SLCs). 24 VDC. UL, ULC, MEA, CSFM and FM Listed.



 
HS-NCM-MF__
(4326)

NOTIFIER  HS-NCM-MF

Notifier HS-NCM High-Speed Network Communications Module. Single or Multi-mode versions available. Allow connection from Notifier Panels to NOTI•FIRE•NET™ with a fiber-optic cable or twisted-pair wire. NFPA Style 4 (Class B) or Style 7 (Class A) operation. 24 VDC, 100Mb baud transmission rate. UL, ULC, CSFM and FM approved.

CPU2-3030D
(6931)

NOTIFIER  CPU2-3030D

Notifier CPU2-3030D Central processing unit for an NFS2-3030 system. Keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control keypad. Requires an AMPS-24(E) power supply.

Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.