Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (132)

GDS  GM/EC-03-20-05

DETECTORS / GAS DETECTORS
AMMONIA

$1,505.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS GM/EC-03-20-05 (1)
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Documents

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Ammonia (NH3) with range 0-50 to 0-1000 ppm, 4-20 mA output transmitter.

Part# with Options:        GM/EC-03-20-05
Price with Options:        1,505.00

Options:    

Sensor Head
(1) Sensor Head for GDS GM/EC (reactive gases) Non-Explosion proof
Enclosure
(2) Stainless Steel Enclosure for GDS
Tag
(3) Tag for GDS
Gas Range
(4) Gas Range for GDS (0-50 to 0-1000)
IS Barrier-Explosion Proof (10-0263)
(5) Intrinsically safe barrier for GDS 2-wire gas detectors
For Explosion-Proof installations, model MTL 7787P+ or equivalent

  Availability 2 Weeks  ]

The GASMAX EC single channel gas monitor for toxic or oxygen deficiency ap- plications delivers the latest in loop-pow- ered gas detection technology, reliability and ease of use.

Wide Variety of Available Sensors

The GASMAX EC support all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more. In addition, GDS Corp Smart Sen- sors enhance this capability by maintain- ing their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX EC constantly tracks sensor performance and calculates an estimate of sensor life remaining. Built-in fault detection circuity constantly monitors the sensor for correct operation.

Advanced User Interface

The highly visible graphic display and flashing alarm LEDs constantly show alarm status, calibrated engineering values and a programmable tag name, plus a trend screen shows alarm levels and a graph of the most recent 30 minutes.

An internal real-time clock and event log time-stamp up to 300 calibration and alarm events for later review. Taking advantage of the high-resolution graphic display, an easy-to-use menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Three operational levels of security al- low the GASMAX EC to be fully field configurable, partially restricted or com- pletely restricted by way of user ID and access code.

Explosion-Proof or Intrinsically Safe

The GASMAX EC is CSA certified for use in Div 1 & Div 2 hazardous areas and can be installed as Explosion Proof (with stainless steel sensor head) or Intrinsi- cally Safe (with aluminum sensor head) using appropriate wiring techniques and an Intrinsically Safe barrier. See notes on IS installation on back. An ATEX certi- fied version for XP installations is also available.

FEATURES

  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Non-polarized loop powered inter- face eliminates wiring errors
  • Graphic display shows values, units, trend graph, alarm levels
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibra- tion with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • For combustible applications, see the GASMAX II gas monitor

Note: Sensor Heads 3, 4 and 8 require INTRINSICALLY SAFE (IS) installations in hazardous locations. IS installations require an IS barrier (#10-0263 MTL 7787P+) or equivalent that must be mounted in an area designated as Non-hazardous.

GASMAX EC SPECIFICATIONS
Power Input: 10-30VDC at less than 0.75 watts in 2-wire 4-20mA configuration
Display 64 x 128 pixel LCD with 30-minute trend, bargraph and engineering units display.
Input Accepts microamp-level signals from local or remote GDS Corp toxic or oxygen deficiency sensors
Calibration Range Zero = +/- 15% of range with 0.1% resolution
Span = Gain adjustment of 0.5 to 2.0 with 0.1% resolution
Accuracy +/- 5% of full scale range (typical)
Standard Output Standard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp -25°C to +60°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel optional
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified Div 1 & 2 Groups B, C, D. Suitable for explosion-proof installations
CSA Certified Div 1 & 2 Groups A, B, C, D. Intrinsically safe.
IMPORTANT: Intrinsically Safe installations require IS barrier #10-0263 (MTL 7787P+) or equivalent.
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made InUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-9520-R05 Electrochemical Smart Sensor configured for Ammonia with range 0-50/0-1000 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX ..

  • ACCESSORIES > GDS POPULAR ACCESORIES
    10-0203 GDS Sensor calibration cup for stainless steel / aluminum sensor heads ..

  • BARRIERS > GDS GASMAX II, GASMAX EC GAS MONITOR
    10-0263 GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent ..

  • CALIBRATION GAS GDS > AMMONIA
    1200-0260 GDS Gas Detector Calibration Gas Cylinder Ammonia (NH3) 50ppm. Balance Air. 58L Aluminium Cylinder. ..

  • CALIBRATION GAS GDS > AMMONIA
    1200-0280 GDS Gas Detector Calibration Gas Cylinder Ammonia (NH3) 300ppm. Balance Air. 58L Aluminium Cylinder. ..

  • CALIBRATION KITS GDS > AMMONIA
    1200-0501 GDS Gas Detector Calibration Gas Kit Ammonia (NH3) 50ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of calibration gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • CALIBRATION KITS GDS > AMMONIA
    1200-0502 GDS Gas Detector Calibration Gas Kit Ammonia (NH3) 300ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of calibration gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > AMMONIA :    48 Items found.
6300-1116
(2674)

BACHARACH  6300-1116

Bacharach MGS-150 Gas Detector Transmitter with semiconductor sensor for Ammonia (NH3) for Industrial and Commercial Refrigeration. 4-20mA, 0-5V, 0-10V, 1-5V or 2-10V user selectable analog outputs. Onboard Alarm LED, audible buzzer and alarm relay. IP41 Housing (IP66 optional) and Remote sensor option. CE, IEC61010, Exd and UL CSA Approvals.

Configure

$198.00 
MP100-NH3-50
(5993)

MACURCO  MP100-NH3-50

Macurco UNI Portable Single Gas Detector for detection of Ammonia (NH3) 0-50ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$276.25 
6300-1029
(2673)

BACHARACH  6300-1029

Bacharach MGS-150 Gas Detector Transmitter with electrochemical sensor for Ammonia (NH3) for Industrial and Commercial Refrigeration. 4-20mA, 0-5V, 0-10V, 1-5V or 2-10V user selectable analog outputs. Onboard Alarm LED, audible buzzer and alarm relay. IP41 Housing (IP66 optional) and Remote sensor option. CE, IEC61010, Exd and UL CSA Approvals.

Configure

$414.00 
TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$497.26 
TX-12-AM
(3418)

MACURCO  TX-12-AM

MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$499.43 
G02-B810-100
(3023)

RAE  G02-B810-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Ammonia (NH3) 0-100 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$555.75 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$585.77 
GAXT-A-DL
(484)

BW  GAXT-A-DL

BW GasAlertExtreme Portable detector with gas concentration readout for Ammonia (NH3) 0-100 ppm.

Configure

$597.52 
GAXT-A2-DL
(485)

BW  GAXT-A2-DL

BW GasAlertExtreme Portable detector with gas concentration readout for Ammonia (NH3) 0-400 ppm. (extended range)

Configure

$613.36 
SPC3-1120-200US
(2633)

INTEC  SPC3-1120-200US

Intec Controls PolyGard SPC3-1120 Sigle-Point Gas Detector for Ammonia (NH3) 0-300 / 0-1000 ppm, 2 relay outputs, 1 4-20mA & 2-10V analog output, 83 db horn. Wall mounted. NEMA 4X Enclosure. Accepts one additional analog remote device and a secondary gas, temperature or humidity sensor. UL Listed and CSA Certified.

Configure

$620.73 
8318979
(2643)

DRAEGER  8318979

Draeger Pac 7000 small single gas detector for Ammonia (NH3) 0-300 ppm for personal monitoring. TWA and STEL alarms. IP65. CE, ATEX, UL, IECEx, MED and ATEX Approvals. Class I, II Div 1.



$624.68 
10154079
(4716)

MSA  10154079

MSA ALTAIR 2XP Portable Single Gas Detector with XCell Pulse Technology for Ammonia (NH3) 25-50ppm. Stand-alone bump test. Offers superior stability, accuracy, and sensor life. Polycarbonate Housing. 25 feet drop test. 95dB audible alarm. Monochrome LCD Display. Minimal rF interference. IP67. cCSAus, ATEX and IEC Approved.



$651.22 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$700.80 
2106B1413
(1458)

HONEYWELL  2106B1413

Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

Configure

$728.91 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$768.95 
GG-NH3-0100
(2966)

CALIBRATION TECHNOLOGIES  GG-NH3-0100

CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$861.30 
LBW-50-115-SS
(910)

COOL AIR  LBW-50-115-SS

Cool Air LBW-50 Ammonia (NH3) 0-1000ppm Gas Leak Detector. Dependable, low cost and low maintenance. NEMA 4X IP66 enclosure. Alarm, pre-alarm and auxiliary relays. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC

Configure

$878.15 
LBW-50-RLV-115-SS
(914)

COOL AIR  LBW-50-RLV-115-SS

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed

Configure

$878.15 
GG-VL2-NH3
(2970)

CALIBRATION TECHNOLOGIES  GG-VL2-NH3

CTI GasGuard NH3 Ammonia Vent Line 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless enclosure.

Configure

$887.40 
GG-NH3-2
(2967)

CALIBRATION TECHNOLOGIES  GG-NH3-2

CTI GasGuard NH3-2% Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressor rooms, emergency shutdown, E-stop, heat treatment and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$887.40 
Page: 1 | 2 | 3 | All