Honeywell Ecfx-100-n | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   ECFX-100-N

HONEYWELL ECFX-100-N
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-100 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.
HA# M-509320

ECFX-100-N   
1,898.10

Options

   4 Weeks  ]



Ammonia Specific
  • Rapid response to ammonia
  • Internal monitoring of 4-20 mA loop circuitry continuity
Versatility
  • Can be used with any Honeywell Analytics readout
  • Standard range of 100 ppm can be rescaled for higher ranges
  • Provides a linear output of 4-20 mA as a function of refrigerant concentration
Easy Maintenance
  • Quick and easy calibration
  • Realtime calibration eliminates maintenance downtime
Long sensor life
  • Quick and easy calibration
ATMOS™ Technology
  • Allows for operation down to -50 F and in condensing humidity environments or during washdown
  • Automatically adapts to its environment and provides accurate and reliable performance under the harshest conditions
SensorCheck™ Technology
  • Checks operating parameters of sensors and sends a notification output signal if an anomaly is identified
  • Tests the sensor every 24 hours for electrical viability
  • Indication can be detected by a Manning gas monitor or PLC
Housing
  • NEMA 1 #16 gauge heavy-duty steel enclosure
  • Explosion-proof design available
Available with an optional LCD that allows real time display of gas concentration. The easy to read display allows for quick visual error events upon startup and troubleshooting and can be calibrated without a voltmeter. The EC-F9-NH3 with LCD is designed to work in the harshest environments including chemical washdown.
Manning EC-F9-NH3 with LCD
Manning EC-F9-NH3 with LCD option

General Description

The Manning EC-F9-NH3 sensor consists of a pair of polarized electrodes isolated from the ambient air by a gas permeable membrane. As ammonia diffuses into the sensor, a redox reaction occurs, generating a current linearly proportional to ammonia gas concentration. Unlike many other ammonia sensors, this gas diffusion detector exhibits excellent zero and calibration stability over long periods of time. EC cells often last 3-4 years in the refrigerated environments of food processing and storage warehouses. This sensor can provide direct input into PLC’s and computer control systems that accept a linear 4-20 mA signal either directly from the sensor or from any Manning mulitchannel stand alone alarm consoles with relay or analog output.

Applications

  • Bakeries
  • Beverage, Bottling Plants
  • Blast, Spiral Freezers
  • Chemical Manufacturing
  • Gas Bottling Plants
  • Coolers
  • Duct-Mounted Sensors
  • Equipment Rooms
  • Food Processing
  • Fruit, Vegetable Processing
  • Ice Cream Storage
  • Penthouses
  • Perimeter Monitoring
  • Potable Water Plants
  • Poultry, Meat, Fish Processing
  • NOx Reduction (power plants)
  • Refrigeration Systems
  • Storage Freezers
  • Turbine Inlet Cooling
  • Wineries

General Specification
Use Electrochemical (diffusion) type sensor that works in conjunction with any Honeywell Analytics readout or alarm unit. Readouts have built in visual and audible alarms, as well as relay output for ventilation fan activation, central alarm tie-in, etc. The Manning EC-F9-NH3 can provide a linear 4-20 mA signal input into PLC’s.
Common Operation
OperationIn units without the optional LCD module, a group of LED’s are installed to the PCB. In units with the optional LCD, two external
push buttons, “Accept” and “Scroll” are used to navigate test functions and operating modes.
LCD display (optional)2 line by 8 alpha numeric characters and continuous backlight
OutputIsolated 4-20 mA, 700 ohms max. at 24 VDC. Signal output reduces to 0.5 mA to indicate a fault condition. RS-485, Modbus
RTU protocol
Accuracy+/- 5% generally, but limited by available calibration gas accuracy. Enclosure contains no moving parts, contributing to accu
racy levels.
Environmental IP ratingIndoor use, IP 44 in accordance with EN60529:1992
Operational
Humidity5-100% RH (condensing)
Temperature-45°C to +49°C / -50°F to +120°F, ATMOS equipped enviro-adaptive technology required for refrigerated areas or outdoors
Sensor Pressure Limit0-10 PSIG
Storage-40°C to +80°C / -40°F to +176°F, 20 to 80%RH (non condensing)
Common Module
Communication 4-20 mA output: #18/3 shielded cable (Belden 8770 or equal), cable runs < 1,500 ft. RS-485: for communication cable, use
24 AWG twisted pair, shielded (Belden #9841 or equal), cable runs up to 2,000 ft. For power cable use 14 AWG (Belden
#5100UE or equal), cable runs up to 1,000 feet.
Power Source24 VDC, 0.5 amp max.
Repeatability+/- 2% full scale
Sensor Specifications
Sensor PressureLimits 0-10 PSIG
Response TimeT50 = 10 seconds
T100 < 1 second for concentration > 1% NH3
Ranges0-100 ppm (standard)
0-250 ppm
0-500 ppm
0-1000 ppm
Sensor Viability TestSensorCheck, an internal microprocessor determines the sensor’s electrical viability every 24 hours. If the viability test fails, an
0.5 mA signal will idicate a fault. An internal light will show if a sensor is dried up or disconnected.
EnclosureNEMA 1, gasketed, #16 gauge steel (standard). Stainless steel or explosion-proof designs, including modified enclosures for
low temperatures, ventilation ducts, etc. are available.
Weight 3 Lbs.
Export Info
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    6 Items found.
(6589)

HONEYWELL  EC-FX-CA

Honeywell ECFX Calibration adapter for Honeywell Manning EC-FX



$100.57 
(1491)

HONEYWELL  M-510150

Honeywell LCD display for Manning EC-F9-NH3



 
CYL-10005500
(1268)

PORTAGAS  CYL-10005500

Calibration Gas Ammonia (NH3) 100 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$252.43 
(3705)

HONEYWELL  EC-FX-CK2

Honeywell ECFX Calibration Kit with 0.3LPM C-10 Regulator for 34, 58 or 103L Aluminum Cylinder. Includes EC-FX-CA calibration adapter (cap), regulator, tubing, and carrying case.



$428.20 
2306B1000
(1503)

HONEYWELL  2306B1000

Zareba Unipoint simple DIN rail mounted 1-channel controller with 2 wire 4-20mA, 3 wire 4-20 mA , 3 alarm relays and built-in audiovisual alarms. Flexible and low cost solution to incorporate toxic or oxygen gas detection into control and gas detection systems.



$604.31 
AA96D-DLC
(1999)

HONEYWELL  AA96D-DLC

Honeywell Manning AirAlert 96d Multi-Channel gas monitoring system for continuos monitoring and control of toxic gases, combustible gases and oxygen hazards. Supports up to 96 addressable devices, any combination of Honeywell Analytics gas detectors (Manning, XCD, XNX, etc.) over Modbus and up to 126 zones. Includes 122x32 LCD display.

> AMMONIA :    42 Items found.
M001-0006-000
(5993)

MPOWER  M001-0006-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ammonia (NH3) 0-100ppm or 0-500ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$318.40 
BWS1-A_-Y
(6382)

BW  BWS1-A-Y

BW Solo Serviceable Single-gas Detector for Ammonia (NH3) 0-100 ppm or 0-1000ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$687.74 
TX-12-AM
(3418)

MACURCO  TX-12-AM

MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$690.96 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-4824
(6803)

PROSENSE  PC3-4824

Prosense PC3-4824 Gas Detector with Electrochemical sensor for Ammonia (NH3) with range 0-100 ppm or 0-1000 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-4834
(6778)

PROSENSE  P-4834

Prosense P-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$979.29 
PQN-4834-1/2
(6920)

PROSENSE  PQN-4834-1/2

Prosense PQN-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$1,086.50 
LBW-50-1-SS
(910)

COOL AIR  LBW-50-1-SS

Cool Air LBW-50 Ammonia (NH3) 0-1000ppm Gas Leak Detector. NEMA 4X IP66 enclosure. Alarm, pre-alarm and auxiliary relays. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC

Configure

$1,176.70 
2106B1413
(1458)

HONEYWELL  2106B1413

Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,217.33 
PQD-4834-1/2
(6739)

PROSENSE  PQD-4834-1/2

Prosense PQD-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109012/0300P-L0
(6908)

RC SYSTEMS  1100ALD-109012/0300P-L0

RC Systems SenSmart 1100 gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,314.28 
LBW-50-RLV
(914)

COOL AIR  LBW-50-RLV

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 100 to 240VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed

Configure

$1,332.50 
GG-NH3-0100
(2966)

CALIBRATION TECHNOLOGIES  GG-NH3-0100

CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,349.00 
GG-NH3-2
(2967)

CALIBRATION TECHNOLOGIES  GG-NH3-2

CTI GasGuard NH3-2% Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressor rooms, emergency shutdown, E-stop, heat treatment and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,394.00 
GG-VL2-NH3
(2970)

CALIBRATION TECHNOLOGIES  GG-VL2-NH3

CTI GasGuard NH3 Ammonia Vent Line 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless enclosure.

Configure

$1,434.00 
100-0008-SS/100-0015-NH3
(4759)

ESP SAFETY  100-0008-SS/100-0015-NH3

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Ammonia (NH3) 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
41001AL-0-1015/0300P/L0
(7158)

RC SYSTEMS  41001AL-0-1015/0300P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,538.96 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.