Gds Gds-49-1-14-08 | Hydrogen | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GDS-49-1-14-08

GDS GDS-49-1-14-08
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GDS-49 Remote Gas Detector Transmitter with Stainless steel sensor head configured for Hydrogen (H2) with range 0-1000 to 0-5000 ppm. 2-Wire 4-20 mA transmitter.

Inquiry

The GDS-49 (Model 10-0248) two-wire toxic sensor transmitter provides a scaled 4-20mA current sink output suitable for long distance transmission to an appropriate receiver device such as a C1 or C2 Protector series controller or GASMAX transmitter.

Wide Variety of Available Sensors

The GDS-49 is compatible with all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more. Built-in fault detection circuity constantly monitors the sensor for correct operation and sensors can easily be replaced in the field.

Rugged Detection

The GDS-49 is enclosed in a stainless steel housing with integrated flame arrestor and is CSA approved for all Class I, Division 1 and 2 hazardous environments. For certain highly reactive gases that are not compatible with stainless steel, the GDS-49 is also available in a configuration without a flame arrestor that can be installed as intrinsically safe (IS) with an approved IS barrier, A standard junction box is supplied with the GDS-49 for connection to field wiring.

Calibration Required

Initial factory adjustment is completed by installing a fixed gain resistor on the sensor. This resistor establishes the range and provides basic calibration. Since the GDS-49 electronics are completely sealed and potted for maximum protection, final calibration must be performed at the receiver device in order to meet the rated accuracy specifications and accomodate changes in sensor characteristics over time. GDS Corp. offers single, dual, four, eight and sixteen + channel controllers with compatible analog inputs suitable for final calibration, alarm, display and retransmission of monitored gas values.

Easy Installation

The GDS-49 includes an XP junction box and functions with loop voltages ranging from 10-30VDC; voltage drop across the GDS-49 is less than 9 volts. An integral “transient voltage suppressor” protects the GDS-49 against lightning and other electrical transients. Non-polarized wiring elimnates wiring errors.

FEATURES

  • Certified for Explosion Proof and Intrinsically Safe Installations
  • Compatible with all GDS Corp toxic sensors
  • Non-polarized loop powered interface eliminates wiring errors
  • Range and target gas configured by sensor module
  • Fault supervision circuitry detects failed or missing sensor & transmits warning (2mA)
  • Stainless steel case & potted electronics for high noise immunity in electrically noisy environments
  • Industry standard 4-20mA output signal for cable runs > 1000 ft
  • Available without flame arrestor for highly reactive gases
  • Easy interface to all GDS Corp 2, 4, 8 or 16+ channel controllers
  • Combine with GDS-55 Loop-Powered Alarm or GDS-54 Loop-Powered Indicator for more flexibility
  • Manufactured in USA

GDS-49 (Model 10-0248 & 10-0248IS) SPECIFICATIONS
Power Input: 10 - 30VDC 4 - 20mA current loop with less than 9V drop across GDS-49; Maximum 32mA draw with overrange sensors
Display None
Input Accepts microamp-level signals from local GDS Corp toxic or oxygen deficiency sensors
Calibration Range Rough calibration set by sensor; final calibration must be performed by remote receiver device
Accuracy +/- 5% of full scale range (typical)
Standard Output Standard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp --25°C to +60°C (see sensor limitations)
Housing GDS-49 Stainless steel with or without flame arrestor
Dimensions Width 5.3” x Height 9.3” x Depth 2.75” with splash guard
Shipping weight 6.5 pounds (3 kg)
Approvals Model 10-0248 CSA Certified for Div. 1 & 2 Groups B, C, D Exia. Suitable for Explosion Proof and Intrinsically Safe installations.
Model 10-0248IS CSA Certified for Div. 1 & 2 Groups A, B, C, D. Suitable for Intrinsically Safe only.
IMPORTANT: Intrinsically Safe installations require IS barrier 10-0263 (MTL 7787P+) or equivalent./td>
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
FC-11
(1563)

AUTOMATION DIRECT  FC-11

Signal conditioner and isolator with loop-powered 4-20 mA input and output signal; output can be field calibrated with offset and span adjustments. Slim-line plastic housing with integral 35mm DIN rail mounting adapter and removable screw terminals, 24VDC supply voltage. UL 508 listed, UL listed for Class I, Division 2, Groups A, B, C, D hazardous locations.



$174.00 
1200-0545
(3175)

GDS  1200-0545

GDS Gas Detector Calibration Gas Cylinder Hydrogen (H2) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

(261)

GDS  10-0263

GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent



 
1200-0511
(3105)

GDS  1200-0511

GDS Gas Detector Calibration Gas Kit Hydrogen (H2) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

10-9014-R08
(2057)

GDS  10-9014-R08

Electrochemical Sensor for GDS-49 remote transmitter configured for Hydrogen (H2) with range 0-1000/0-5000 ppm.

10-9514-R19
(327)

GDS  10-9514-R19

Electrochemical Smart Sensor configured for Hydrogen (H2) with range 0-1% or 0-4% vol. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-49, GDS-58XP.

90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
> HYDROGEN :    24 Items found.
M001-0019-000
(6329)

MPOWER  M001-0019-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen (H2) 0-1000ppm or 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$278.40 
P-3634
(6776)

PROSENSE  P-3634

Prosense P-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm to 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$540.54 
PQN-3634-1/2
(6948)

PROSENSE  PQN-3634-1/2

Prosense PQN-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
BWS1-R-Y
(6387)

BW  BWS1-R-Y

BW Solo Serviceable Single-gas Detector for Hydrogen (H2) 0-1000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PQD-3634-1/2
(6737)

PROSENSE  PQD-3634-1/2

Prosense PQD-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$875.16 
SPSTAXG1
(1487)

HONEYWELL  SPSTAXG1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen (H2) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-1000 ppm, 0-10000 ppm)

Configure

$929.07 
GG-H2-EC-2000
(2965)

CALIBRATION TECHNOLOGIES  GG-H2-EC-2000

CTI GasGuard H2 Hydrogen Catalytic Bead Sensor 0-1% (10000 ppm or 25%LEL) for gas leak detection in battery charging rooms, steel industry, refineries and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
2106B1416
(1462)

HONEYWELL  2106B1416

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen (H2) (0-1000 ppm to 0-10000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
GG-H2-EC-10000-EXP
(5978)

CALIBRATION TECHNOLOGIES  GG-H2-EC-10000-EXP

CTI GG-H2-EC-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen (H2) 0-2000 ppm and 0-10000 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,383.00 
100-0008-SS/100-0015-H2
(4753)

ESP SAFETY  100-0008-SS/100-0015-H2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Hydrogen (H2) 0-4% vol or 0-100ppm (Catalytic bead or electrochemical). Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
SPXCDULNG1
(665)

HONEYWELL  SPXCDULNG1

Honeywell XCD Sensepoint Gas Detector, Hydrogen (H2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for hydrogen (H2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 1,000ppm only. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,566.91 
961-070026-01PG
(6053)

DETCON  961-070026-01PG

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-1%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

961-840026-100G
(6363)

DETCON  961-840026-100G

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

S3KUL2-XNXXSG1SS
(689)

HONEYWELL  S3KUL2-XNXXSG1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN (H2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-1,000ppm ,0-10,000ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,806.92 
SPXCDULNG2
(5102)

HONEYWELL  SPXCDULNG2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen (H2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 1000 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
2100AL-0-1018/0500P/L0
(120)

RC SYSTEMS  2100AL-0-1018/0500P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$2,003.89 
41001AL-0-1019/0500P/L0
(7163)

RC SYSTEMS  41001AL-0-1019/0500P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$2,025.97 
51001AL-0-1019/0500P/L0
(7126)

RC SYSTEMS  51001AL-0-1019/0500P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$2,081.82 
31001AL-0-9018/2000P/L0
(5782)

RC SYSTEMS  31001AL-0-9018/2000P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,181.82 
XNXUTAENNNNN-XNXXSG1SS
(839)

HONEYWELL  XNXUTAENNNNN-XNXXSG1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen (H2) compatible with all Honeywell gas sensing technologieswith aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-1000ppm, 0-10000ppm

Configure

$2,221.73 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.