GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Inquiry

Features

  • CSA Certified for Class I, Div 1 explosion-proof installations
  • Monitor any combination of toxic and combustible gases
  • High resolution color TFT display for easy recognition of alarm status
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibra- tion with programmable cal value
  • Dual independent 4-20mA analog outputs with 0-4mA pass-through
  • Standard Ethernet port with built- in web server for remote access
  • Power-up and post-calibration delays eliminate false alarms
  • Backlit display for better visibility in low light conditions
  • Optional 4x SPDT alarm relays and dual MODBUS serial ports
  • Graphic display shows values, units, trend graph, alarm levels
  • Security settings allow user to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand
  • Manufactured in USA

The new GASMAX CX gas monitor from GDS Corp delivers quality, performance and advanced features for the most critical gas detection applications. Designed especially for situations where gas readings need to be transmitted in real time via a variety of communication options, the GASMAX CX includes dual 4-20mA outputs and built-in Ethernet port with MODBUS/TCP and web server. An optional output board incldues 4X alarm relays and dual serial MODBUS channels with data rates up to 115k bits per second.

Widest Variety of Available Sensors

Built-in dual channel electronics allow the GASMAX CX to support almost any combination of GDS Corp toxic, bridge or 4-20mA sensors. Channel 1 features a dedicated bridge input configuration for traditional direct catalytic bead sensors, and both channels support the new 10- 98xx digital output low-noise sensors. Built-in sensor monitoring circuitry detects sensor faults or warns of missing sensors.

Advanced User Interface

The highly visible full color TFT backlit display makes the GASMAX CX gas monitor extremely easy to read and operate, and magnetic switches arranged around the screen allow users to perform calibrations or change settings without opening the enclosure. Bright flashing yellow or red alarm screens give users the ability to instantly recognize alarm conditions and take appropriate action.

Reliable, Dependable, Certified

The GASMAX CX carries a full two-year warranty and is fully CSA certified for use in Class I Division 1 hazardous areas.

Power Input 10-30VDC at < 10 watts with relay board (all relays energized)
DisplayQVGA color TFT display with value, 30-minute trend and bargraph
Channel One InputDigital sensor, bridge-style direct sensor or 4-20mA analog input
Channel Two InputDigital sensor or 4-20mA analog input
Standard OutputDual 3-wire 4-20mA current source. Max loop R is 600 ohms @ 24VDC
Ethernet RJ-45 with built-in web page for remote acces
Optional OutputThree programmable relays plus dedicated FAULT relay
Dual programmable master / slave MODBUS RS-485 serial interfaces
EnvironmentalOperating range -40°C to +60°C
Sensors include sensor heater for low temperature operation
Relative humidity to 95% non-condensing with GDS-IR; to 85% non- condensing when using electrochemical sensors
HousingAluminum housing with epoxy paint standard; Optional #316 stainless steel housing (specify [SS] in part number)
DimensionsWidth 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D.
Warranty 2 years on electronics and one year on sensors
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
10-0203
(259)

GDS  10-0203

GDS Sensor calibration cup for stainless steel / aluminum sensor heads



 
1200-0285
(3177)

GDS  1200-0285

GDS Gas Detector Calibration Gas Cylinder Hydrogen Cyanide (HCN) 10ppm. Balance Nitrogen. 58L Aluminium Cylinder.

10-9816-R12
(3356)

GDS  10-9816-R12

Electrochemical Smart Sensor configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. For GDS GASMAX CX, GDS-58NXP, GDS-68XP, GDS-78XP.



 
1200-0513
(3107)

GDS  1200-0513

GDS Gas Detector Calibration Gas Kit Hydrogen Cyanide (HCN) 10ppm. Balance Nitrogen. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
> HYDROGEN CYANIDE :    16 Items found.
M001-0005-000
(5999)

MPOWER  M001-0005-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.



$358.40 
BWS1-Z-Y
(6388)

BW  BWS1-Z-Y

BW Solo Serviceable Single-gas Detector for Hydrogen cyanide (HCN) 0-100 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

P-7534
(6789)

PROSENSE  P-7534

Prosense P-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$1,158.30 
1100ALD-109020/30P-L0
(6912)

RC SYSTEMS  1100ALD-109020/30P-L0

RC Systems SenSmart 1100 gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
PQN-7534-1/2
(6962)

PROSENSE  PQN-7534-1/2

Prosense PQN-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,338.48 
PQD-7534-1/2
(6750)

PROSENSE  PQD-7534-1/2

Prosense PQD-7534 Gas Detector with Electrochemical sensor for Hydrogen Cyanide (HCN) with range 0-25ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,492.92 
41001AL-0-1020/0030P/L0
(7165)

RC SYSTEMS  41001AL-0-1020/0030P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1020/30P/L0
(7128)

RC SYSTEMS  51001AL-0-1020/30P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-130026-030G
(6366)

DETCON  961-130026-030G

Detcon DM-100-HCN Electrochemical Hydrogen Cyanide (HCN) 0-30ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

2100AL-0-9020/30P/L0
(127)

RC SYSTEMS  2100AL-0-9020/30P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
S3KUL2-XNXXSY1SS
(6346)

HONEYWELL  S3KUL2-XNXXSY1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN CYANIDE (HCN) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display, 0-30ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,899.32 
31001AL-0-9020/30P/L0
(5783)

RC SYSTEMS  31001AL-0-9020/30P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical Smart Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

6100AL1-0-1020/0030P
(7007)

RC SYSTEMS  6100AL1-0-1020/0030P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen Cyanide (HCN) 0-30ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,391.48 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.