GasDetectorsUSA.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to GasDetectorsUSA.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA     Español Detectores de gas para Latinoamerica
281­-643­-0080
Call Us! 9am-5pm CST
Gas leak detectors, analyzers, alarm devices and calibration gas
         
PRODUCTS & SERVICES
Legal Exposure Limits
[ NIOSH Exposure Limits ]


Federal Government Contractor
(SAM) CAGE Code: 4W5M0

Why GasDetectors.com ?

  • GasDetectorsUSA.com provides a wide range of industrial gas detection systems including toxic, oxygen and combustibles, truly "state of the art" devices offering unparalleled features and capabilities along with Hazardous Area, Explosion Proof, UL, Atex and CSA certifications at a reasonable price. We also offer gas detection solutions with PLC & SCADA.

  • Our Broad spectrum of skills, experience and hands-on approach ensures the success of Your project
  • We provide specialized products, services or turnkey projects, to suit your needs in
    • Fixed gas detectors.
    • Portable gas detectors.
    • Multi-Point gas controllers.
    • Calibration Gases.
    • Alarm Signal Devices.
    • Installation and commissioning.
    • PLC-based gas detection solutions.
    • Data acquisition and SCADA.


Houston, TX USA

SKU#(3344) Be the First to Review this Item

GDS  GDS-58NXP0/45-110-06/0-00-0/0

MONITORS / SAMPLE DRAW
LEL INFRARED


 Information Request
 Shipping Rates
 Volume discount
      



GDS GDS-58NXP0/45-110-06/0-00-0/0
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

GDS GDS-58NXP Sample Draw Gas Detector and Monitoring System with local stainless steel sensor head configured for GDS-IR Infrared Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit). Includes Sample Pump, QVGA color TFT High Visibility LCD Display, 4-20mA output plus 4 Form C 5A alarm relays, Ethernet Modbus TCP RJ-45 port with built-in web server and RS-485 MODBUS RTU slave interface. CSA Approved for Hazardous Locations. Class I Div 1. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alchohol and others.

Part# with Options:        GDS-58NXP0/45-110-06/0-00-0/0
Price with Options:        Please Email us your request for quote   

Options:    

Sample Conditioning
(1) Sample Conditioning for GDS GDS58-XP & GDS78-XP
Sensor Type (GDS-IR channel)
(2) Sensor Type for GDS GDS-58XP/GDS-78XP (GDS-IR)
Mounting Options
(3) Mounting Plate and Enclosure Options for GDS GDS-58NXP
Enclosure Options
(4) Enclosure Options for GDS GDS58-XP
Tag
(5) Tag for GDS
Drain
(6) GDS-30 Timed Automatic Drain for 58XP, 58NXP or 58GP
Enclosure heater
(7) Enclosure heater for GDS 58XP, 58NXP or 58GP

  Availability 3 Weeks  ]

The GDS-58NXP sample draw system is an ideal solution for applications where ambient conditions are unsuitable for traditional ambient sensors, or where access to an ambient sensor would be inconvenient or dangerous. The GDS-58NXP sample draw features the new GASMAX CX gas monitor with DigitalSensor technology and advanced Ethernet / MODBUS communications. Together with a fully integrated long-life brushless sample pump, adjustable flow meter and low flow warning switch, the highly reliable GDS-58NXP can monitor locations up to 500 feet away.

GASMAX CX Gas Monitor

The new GASMAX CX dual channel gas monitor supports new GDS Corp Digital Sensors for toxic and combustible gases as well as volatile organics and inert gases such as CO 2 . The high contrast full color graphic display shows system status, gas values, programmable tag name and engineering units under full daylight conditions. Unlike previous generation detectors with point LEDs, the GASMAX CX signals alarms by flashing the entire screen, making alarm indications clearly visible to operators and technicians. A menu-driven operator interface eliminates all analog potentiometers and allows setup and calibration without hazardous area declassification. An integrated Run / Calibrate valve and user prompted calibration procedure make routine maintenance and field ‘bump tests’ quick and easy.

Reliability in Hostile Environments

Utilizing a long-life brushless DC pump, the GDS-58NXP Sample Draw is suitable for installation in hazardous areas rated Class I, Div 1, Groups B, C & D.

The GDS-58NXP is ideal for sampling toxic or combustible gases in:

  • Sumps and enclosed areas
  • Cabinets or storeroom with limited ventilation or airflow
  • Air conditioning intake or exhaust plenums and ducts
  • Boiler burners and ducting
FEATURES

  • Single or dual channel - monitor both H2S and LEL simultaneously
  • Supports electrochemical, PID, catalytic bead and infrared sensors
  • High quality diaphragm pump with 24VDC brushless motor
  • Designed for use in Class I, Div 1 Hazardous Locations
  • High visibility color display flashes yellow or red on alarm
  • Setup in hazardous area requires only simple magnetic wand
  • Integrated flow warning switch for ultra-reliable remote operation
  • Built-in flow meter provides visual confirmation of sample flow rate
  • Standard RJ-45 Ethernet interface with built-in web server
  • Prompted calibration procedure and cal port for easy maintenance
  • Sample lines up to 500 ft in length with latency less than 4 minutes
  • Optional 4x alarm relays and dual serial MODBUS interface
  • GASMAX CX auto-configuration with DigitalSensor technology
  • Optional matching 110/220VAC power supply available
  • Manufactured in USA
GDS-IR Features

The GDS-IR Infrared Gas Sensor uses proven, reliable infrared sensing technology to detect dangerous levels of carbon dioxide or explosive levels of methane, propane and other hydrocarbons. The GDS-IR sensor is CSA certified for use in Class 1 Division 1 explosive environ- ments and is CSA performance tested.

Advanced Infrared Technology

The GDS-IR infrared combustible gas sensor offers low total cost of ownership and a seventeen-year MTBF rating. Designed for especially harsh environments, the GDS-IR is virtually maintenance-free and immune to poisoning or etching by any known gas. The sensor element features a self-compensating optical bench, heated optical chamber and fault indication for all failure modes. The optical path can be easily opened for cleaning.

No periodic span calibrations are required. On initial setup and after each cleaning, a simple ‘auto zero’ procedure is used to establish proper operating conditions.

Flexibility

The GDS-IR can be calibrated to read a wide range of combustible hydrocarbons, including methane, propane, hexane, pentane, ethanol, Jet-A, isobutane, propylene and isoproply alcohol, as well as carbon dioxide to 5% by volume. GDS-IR sensors are factory programmed and calibrated when shipped and can be field programmed for alternate response curves. Both LEL and % by volume ranges are available.

GASMAX + GDS-IR Combo

When combined with the GASMAX II monitor, the duo provides local display, 4-20mA output with diagnostics, optional second electrochemical sensor, isolated 4-20mA outputs or MODBUS slave interface with programmable relays.

Reliable Detection

The GDS-IR is manufactured in the USA and includes a five year operational warranty. Applications include refineries, onshore and offshore drilling platforms, fuel loading docks, biogas processing, breweries, wastewater treatment facilities and natural gas storage and distribution.

FEATURES

  • Suitable for use in SIL-2 rated safety systems
  • High speed response for critical applications (T50 less than 3 sec)
  • 5 Year Warranty and long life lowers total cost of ownership
  • 12 Year Warranty on infrared radiation source
  • Rugged stainless steel construction with no moving parts
  • Heated optical chamber maintains accuracy in cold conditions
  • Operates in constant hydrocarbon and anaerobic atmosphers
  • Ten discrete fault indication values for all failure states
  • Straight line optical path eliminates need for mirrors
  • Managed power-up delay reduces initial load on power supply
  • Industry standard 4-20mA current loop calibrated output
  • Multiple gas calibration curves for %LEL and % by volume
  • CSA Certified C22.2 No. 152-M1984 Performance Tested
  • Manufactured in USA

GDS-58NXP SPECIFICATIONS
Power Input: 24VDC +/- 5% at < 10 watts. Optional 110/220VAC power supply available in separate enclosure.
Display High visibility color LCD displays engineering units, alarm levels and trend data
Sensor Channel One Supports bridge-type sensors, electrochemical sensors and 4-20mA input devices such as the GDS-IR Infrared Sensor
Sensor Channel Two Supports electrochemical sensors and 4-20mA input devices such as the GDS-IR Infrared Sensor
Standard Output Single or dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply.
10/100 Ethernet with MODBUS/TCP and web server
Optional Output Four Form C Relays 5A @ 30VDC / 240VAC Dual RS-485 2-wire MODBUS® interface
Sample Pump 1.6L diaphragm pump with brushless 24VDC motor
NOTE: Pump may not start at temperatures below 0°C Integral flow switch generates FAULT output on 4-20mA if flow blocked or pump fails
Temp 0°C to +55°C operating
Housing Aluminum housing with epoxy paint
#316 stainless optional
Dimensions 16” x 12” x 5” for sensor types 10 - 70, 10 pounds
16” x 15” x 5” for sensor types 110+, 14 pounds
Plate, 17” x 15”, for single detector
Plate, 21” x 17”, for dual detector or 110VAC supply
Inlet / Outlet 1/4” compression, stainless steel
Approvals GASMAX II CSA Certified for Class I, Div 1, Grps B, C, D.
Enclosure rated Class II, Div 2 Grps E, F, G.
Suitable for XP installations2
Warranty 2 years from date of purchase on electronics


  • SOLAR POWER > POWER SUPPLIES
    SP-5 GDS SP-5 solar power system, 5 watts (430mA) of DC power for up to 5 days of low sun conditions, or 3 watts for up to 7 days of low sun conditions. Includes 80Wsolar panel, battery enclosure with pre wired electronic charge controller, 99AH gelled electro..


  • SOLAR POWER > POWER SUPPLIES
    SP-12 GDS SP-12 solar power system, 12 watts (1.0A) of DC power for up to 5 days of low sun conditions, or 5 watts for up to 10 days of low sun conditions. Includes 150W solar panel, battery enclosure with pre wired electronic charge controller, two 84AH gelled..


  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1-SM-0000-000000-00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional..


  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


  • CALIBRATION GAS GDS > METHANE
    1200-0768 GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder. ..


  • CALIBRATION KITS GDS > METHANE
    1200-0587 GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder...


  • CALIBRATION GAS GDS > METHANE
    1200-0267 GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder. ..


  • CALIBRATION KITS GDS > METHANE
    1200-0522 GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..


  • DUCT KITS > GDS GDS-58XP SAMPLE DRAW MONITOR
    20-0141 GDS Duct Sample Kit for GDS-58XP, GDS-58NXP and GDS-68XP sample draw gas detectors ..



B2B Checkout Options: PO#, Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> SAMPLE DRAW > LEL INFRARED :    1 Items found.
GDS-58XP20/45-110-06/1-0 (3324) GDS  GDS-58XP20/45-110-06/1-0

GDS GDS-58XP2 Single Channel Sample Draw System for Gas Measurement with local stainless steel sensor head configured for GDS-IR Infrared Methane (Natural Gas) with range combustible 0-100% LEL (Lower Explosive Limit). Designed for Hazardous Locations used in situations where the installation of a traditional diffusion sensor head is inappropriate. Class I Div 1. Includes 24VDC input and 4-20mA plus 3x 5A alarm relays and RS-485 MODBUS RTU slave interface. Wide selection of hydrocarbons, alcohol, fuel and combustibles: Propane, Isobutane, Pentane, Butane, Ethanol, Methanol, Propylene, Ethylene, Exane, Jet-A, Diesel, Gasoline, Isopropyl Alchohol and others.

  

 

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
GDS-58NXP0/45-110-

Industrial Automation Services
Industrial Automation Services with PLC and SCADA


Previous Button
Next Button

 


| My Orders | Imprint | Terms and Conditions | Contact Us | Get a Quote | Downloads | Sell Here | Mobile View Mobile view |   LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to GasDetectorsUSA.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site
|