Gas leak detectors, analyzers, alarm devices and calibration gas
SKU# (3391)

GDS  TM-EC-48-16-12-0

$1,090.00     Availability: 2 Weeks
 Info/Quote Request
 Shipping Rates
 Volume discount



GDS TM-EC-48-16-12-0
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Documents

GDS TRANSMAX EC Loop-Powered Gas Monitor with stainless steel sensor head (optional DELRIN) and integrated sensor configured for Hydrogen Cyanide (HCN) for range 0-30 ppm. 2-wire 4-20mA current sink output and large LCD Display. Polycarbonate housing (IP66/IP67).

Part# with Options:        TM-EC-48-16-12-0
Price with Options:        1,090.00

Options:    

Sensor Head
(1) Sensor Head for GDS TMEC
DELDRIN sensor heads do not utilize Smart Sensor interface
Conduit Entry Options
(2) Conduit Entry Options for GDS TMII

  Availability 2 Weeks  ]

Features

  • High quality gas deteciton for general purpose areas
  • Non-polarized loop powered inter- face eliminates wiring errors
  • Graphic display shows values, units, trend graph, alarm levels
  • Three flashing Alarm LEDs with Programmable Alarm Levels
  • Real time clock tags alarm and calibration events
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Security settings to lock critical parameters
  • Fault supervision circuitry detects failed sensor & transmits warning
  • For combustible applications, see the TRANSMAX II gas monitor
  • Manufactured in USA

The TRANSMAX EC single channel gas monitor for toxic or oxygen deficiency ap- plications delivers the latest in loop-pow- ered gas detection technology, reliability and ease of use.

Wide Variety of Available Sensors

The TRANSMAX EC supports all GDS Corp toxic sensors, including oxygen, hydrogen sulfide, chlorine, carbon monoxide and more (see chart on back). Disposable DELRIN sensor heads with integrated sensors make maintenance easy. Fault detection circuity constantly monitors sensor inputs for missing or faulty sensors.The TRANSMAX EC maintains a record of sensor calibration data and calculates and displays an estimate of sensor life remain- ing at the conclusion of each calibration cycle.

Advanced User Interface

The highly visible graphic LCD display shows the latest reading in large (0.6”) digits, engineering units and program- mable tag name. Flashing LEDs indicate alarm status, a unique feature among loop-powered devices. Activating the NEXT key switches to a trend screen that graphically displays alarm levels and a record of the most recent 30 minute trend. A built-in, prompted calibration procedure simplifies periodic maintenance needs.

An internal real-time clock and event log time-stamp up to 300 alarm events for later review. Taking advantage of the high-resolution graphic display, an easy- to-use menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without opening the enclosure.

Enhanced Security

Three operational levels of security al- low the GASMAX EC to be fully field configurable, partially restricted or com- pletely restricted by way of user ID and access code.

Designed for General Purpose Areas

The TRANSMAX EC is designed spe- cifically for general purpose areas where highly reliable gas detection is required. The enclosure is rated NEMA 4X and IP66/67 for outdoor use. A splash guard is available for the sensor if directed water spray is expected.

Power Input 10-30VDC at less than 0.75 watts
Display64 x 128 pixel LCD with 30-minute trend, bargraph and engi- neering units display.
InputAccepts microamp-level signals from local or remote GDS Corp toxic or oxygen deficiency sensors
Calibration RangeZero = +/- 15% of range with 0.1% resolution
Accuracy+/- 5% of full scale range (typical)
Standard OutputStandard 2-wire 4-20mA current sink output. Max loop R is 600 ohms with nominal 24VDC power supply.
Temp-25°C to +60°C (see sensor limitations)
HousingPolycarbonate housing with transparent cover. Stainless steel screws. Rated IP66/IP67
DimensionsWidth 4.87” (124mm), Height 6” (152mm), Depth 3.75” (95mm)
Shipping weight 3.5 pounds (1.6 kg)
Warranty Two years on electronics and one year on sensors from date of purchase
Export Info
Made InUnited States
Harmonized Tariff Code (HTC)9027102000

  • SENSORS (REPLACEMENT) > GDS ELECTROCHEMICAL SMART
    10-9516-R12 Electrochemical Smart Sensor configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, ..

  • ACCESSORIES > GDS POPULAR ACCESORIES
    10-0301 GDS Sensor calibration cup for DELRIN sensor heads ..

  • CALIBRATION GAS GDS > HYDROGEN CYANIDE
    1200-0285 GDS Gas Detector Calibration Gas Cylinder Hydrogen Cyanide (HCN) 10ppm. Balance Air. 58L Aluminium Cylinder. ..

  • CALIBRATION KITS GDS > HYDROGEN CYANIDE
    1200-0513 GDS Gas Detector Calibration Gas Kit Hydrogen Cyanide (HCN) 10ppm. Balance Air. Kit includes a 58L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, calibration cup and carrying case. Optional Zero Air Cylinder. ..

  • MULTI-POINT CONTROLLERS > 16-CHANNEL
    C1/SM/0000/000000/00000 C1 Multi-Point Alarm gas detector Controller with 8 or 16 channel alarm & display controller for monitoring applications. It can be configured for GAS MAX wireless gas monitors. Standard 5A SPDT common relays and up to 48 discrete relays. 1 or 2 optional ..

  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    C2QUAD-00-00000-0-0 C2 Quad Protector Multi-Point Alarm Controller for gas detectors/transmitters with four channel alarm & display for monitoring applications. Accepts either 4 x 4-20mA, 4 x bridge-type, 2 x mA/2 bridge or wireless devices. It can be configured for GAS MAX ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > HYDROGEN CYANIDE :    17 Items found.
MP100-HCN-100
(5999)

MACURCO  MP100-HCN-100

Macurco UNI Portable Single Gas Detector for detection of Hydrogen Cyanide (HCN) 0-100ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, UL approval for Class I Div 1.



$233.75 
GAXT-Z-DL
(482)

BW  GAXT-Z-DL

BW GasAlertExtreme Portable detector with gas concentration readout for Hydrogen cyanide (HCN) 0-30 ppm.

Configure

$479.60 
6300-1036
(4503)

BACHARACH  6300-1036

Bacharach MGS-150 Gas Detector Transmitter with electrochemical sensor for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA, 0-5V, 0-10V, 1-5V or 2-10V user selectable analog outputs. Onboard Alarm LED, audible buzzer and alarm relay. IP41 Housing. CE, IEC61010, Exd and UL CSA Approvals.

Configure

$522.00 
G02-B710-100
(3022)

RAE  G02-B710-100

ToxiRAE Pro PGM-1860 Personal Portable Monitor For Hydrogen Cyanide (HCN) 0-50 ppm with replaceable sensor, filter and Li-ion battety. Automatic bumb testing and calibration with AutoRAE 2 (optional). Includes Datalogging, Graphical LCD display, 2 buttons for operation and programming. CSA, ATEX, IECEx and China Ex Approved. IP-65. Wireless-capable option.

Configure

$555.75 
10076729
(1660)

MSA  10076729

MSA ALTAIR Pro Portable Single-gas Detector for Hydrogen Cyanide (HCN) 0-30 ppm coupled with LED/audible/flashing/vibrating alarms and with clear, backlit LCD displays. IP67. Superior dust/water protection, high RFI resistance and one-button operation. Available Certifications: Class I, Div. 1, Groups A, B, C and D; Class II,Div. 1, Group G. Alarms: Low 4.7 ppm, High 10 ppm, STEL 10 ppm, TWA 4.7 ppm



$577.98 
8318973
(2642)

DRAEGER  8318973

Draeger Pac 7000 small single gas detector for Hydrogen Cyanide (HCN) 0-50 ppm for personal monitoring. TWA and STEL alarms. IP65. CE, ATEX, UL, IECEx, MED and ATEX Approvals. Class I, II Div 1.



$599.84 
364-455-01-365-790-11
(6153)

DELPHIAN  364-455-01-365-790-11

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Cyanide (HCN) 0-50 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

Configure

$897.60 
TMII-48-16-12/00-00-00/0-0
(153)

GDS  TMII-48-16-12/00-00-00/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head with integrated sensor configured for Hydrogen Cyanide (HCN) for range 0-30 ppm with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter.

Configure

$1,215.00 
GM/EC-01-16-12
(127)

GDS  GM/EC-01-16-12

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head explosion proof (XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter.

Configure

$1,375.00 
EX-HCN-50P-O
(6027)

MACURCO  EX-HCN-50P-O

Macurco Ex Series Explosion Proof Electrochemical Gas Detector for detection of Hydrogen Cyanide (HCN) 0-50ppm. Includes 4-20 mA Output, 3 Onboard Relays, Modbus RS-485 Communication and LCD Digital Display. Aluminium Enclosure. IP66. FM and CSA approvals for Class I Division 1.

Configure

$1,432.09 
GMII-01-016-12/00-000-00/0-0
(140)

GDS  GMII-01-016-12/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

Configure

$1,545.00 
967-131390-030
(6091)

DETCON  967-131390-030

Detcon DM-700-HCN Electrochemical "Smart" Hydrogen Cyanide (HCN) 0-30 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

XNXUTAENNNNN-XNXXSY1SS
(842)

HONEYWELL  XNXUTAENNNNN-XNXXSY1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Cyanide (HCN) 0-30.0ppm, option for Modbus compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop with optional local HART port and Foundation H1 Fieldbus or relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Configure

$1,768.48 
GM/ECx-03-16-12-1-0900
(1814)

GDS  GM/ECx-03-16-12-1-0900

GDS GASMAX/ECX Single Channel Wireless Gas Monitor with Local sensor head (IS) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems.

Configure

$1,925.00 
GMCX-01-16-12/00-00-00/0
(3290)

GDS  GMCX-01-16-12/00-00-00/0

GDS GASMAX CX 3-Wire Gas Detector with local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-30 ppm, QVGA color TFT display, 4-20 mA output transmitter, Ethernet Modbus TCP RJ-45 port with built-in web server. Optional Alarm Relay Board (4x 5A SPDT) and RS-485 Modbus RTU. CSA Certified for Class I, Div 1, Grps B, C, D.

Configure

$2,040.00 
GMIIx-03-016-12/00-000-00/1-0900
(1837)

GDS  GMIIx-03-016-12/00-000-00/1-0900

GDS GASMAX IIx Sigle Channel Wireless Gas Monitor with local sensor head (non-XP) configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. A1, A2 and Fault LEDs for rapid recognition of alarm. 900 MHz or 2.4 GHz Integrated Modems and standard 4-20 mA outputs, 24 VDC.

Configure

$2,120.90 
GM/TX/01-16-12/00-00-00/1-0900
(3426)

GDS  GM/TX/01-16-12/00-00-00/1-0900

GDS GASMAX TX Stand-Alone Wireless Gas Monitor with stainless steel sensor head and integrated sensor configured for Hydrogen Cyanide (HCN) with range 0-30 ppm. Battery-Powerded. 900 MHz or 2.4 GHz Integrated Modems. LCD Display and Aluminium Housing. FCC and IC approvals.

Configure

$2,165.00