Macurco Tx-12-am | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MACURCO   TX-12-AM

MACURCO TX-12-AM
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

TX-12-AM   
690.96

Voltage
Housing Color

   2 Days  ]



The Macurco 12-Series are line voltage (100-240VAC), dual relay gas detector, controller and transducers. The 12-Series utilizes an internal switching power supply that is capable of using line voltage between 100 and 240VAC and 50-60Hz. The 12-Series have selectable 4-20mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of various gases and provide feedback and automatic control to help reduce gas concentrations in parking garages, maintenance facilities or other commercial applications.

Selectable options include:
  • Selectable relay actuation levels
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Buzzer, digital display, latching relay, relay delay, relay minimum runtime
Features:
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Supervised system design: detector problem will cause relay activation
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
12-Series Rear View

Specifications:
Power: 100-240VAC (50 TO 60 HZ)
Current: 1.0 A MAX
Shipping Weight: 1 pound (0.45 kg)
Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
Color: Dark gray
Connections: plugs/terminals
Mounting box: (not included) 4x4 electri
Fan relay: 5A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuation: Selectable within sensor range
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Minimum Runtime settings OFF (default), 3, 5, 10 or 15 minutes
Alarm relay: 0.5A 120 V, 60 VA
Alarm relay actuation: selectable N.O. default or N.C.
Alarm relay settings: Selectable within sensor range
Current Loop 4-20 mA
Operating Environment: 0°F to 125° F (-18°C to 52°C).10 to 90% RH
Buzzer Output: 85 dBA at 10cm settable to off (default) or on
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
CX/TX-CH
(2117)

MACURCO  CX/TX-CH

MACURCO Calibration Hood/cup for CX, TX, OX, & RD series gas detectors: ammonia (NH3), hydrogen sulfide (H2S) and Nitrogen Dioxide (NO2).



$33.38 
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
WHK-1
(3518)

MACURCO  WHK-1

Macurco WHK-1 weatherproof enclosure to protect all Macurco Series 6/12 standard 4x4 mount gas detectors Compatible with CM-6, GD-2A, GD-6, TX-6, OX-6, CX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors. NEMA-1



$183.15 
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
70-2900-0605-3
(2526)

MACURCO  70-2900-0605-3

MACURCO TX-6-AM (TX-12-AM) Ammonia NH3 Replacement sensor. (Replaces 26-2900-0005-4)

Configure

$347.25 
Cal-Kit 5*AM GAS 25PPM
(2996)

MACURCO  Cal-Kit 5*AM GAS 25PPM

Macurco Cal-Kit 5 Ammonia (NH3) 25 ppm gas field calibration kit to calibrate Macurco TX-6 fixed gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood. 1/cs.



$879.27 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
> AMMONIA :    42 Items found.
M001-0006-000
(5993)

MPOWER  M001-0006-000

mPower UNI MP100 Portable Single Gas Detector for detection of Ammonia (NH3) 0-100ppm or 0-500ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$318.40 
BWS1-A_-Y
(6382)

BW  BWS1-A-Y

BW Solo Serviceable Single-gas Detector for Ammonia (NH3) 0-100 ppm or 0-1000ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

TX-6-AM
(2044)

MACURCO  TX-6-AM

Macurco TX-6-AM low voltage Gas Detector, Controller and Transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$687.74 
364-455-01-365-761-11050
(6149)

DELPHIAN  364-455-01-365-761-11050

Delphian GazTell Fixed Point Electrochemical Gas Detector for Ammonia (NH3) 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PC3-4824
(6803)

PROSENSE  PC3-4824

Prosense PC3-4824 Gas Detector with Electrochemical sensor for Ammonia (NH3) with range 0-100 ppm or 0-1000 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$823.68 
P-4834
(6778)

PROSENSE  P-4834

Prosense P-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$900.90 
SPSTAXA1
(1486)

HONEYWELL  SPSTAXA1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Ammonia (NH3) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-50 ppm, 0-1000 ppm)

Configure

$979.29 
PQN-4834-1/2
(6920)

PROSENSE  PQN-4834-1/2

Prosense PQN-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$1,081.08 
LBW-WATCHMAN-SS
(4486)

COOL AIR  LBW-WATCHMAN-SS

Cool Air LBW-Watchman Ammonia (NH3) 0-1000ppm Leak Detector. 4-20mA analog output. NEMA 4X, UL Listed enclosure. IP66. 24VDC.

Configure

$1,086.50 
LBW-50-1-SS
(910)

COOL AIR  LBW-50-1-SS

Cool Air LBW-50 Ammonia (NH3) 0-1000ppm Gas Leak Detector. NEMA 4X IP66 enclosure. Alarm, pre-alarm and auxiliary relays. 115 or 230 VAC, 50/60 Hz, 16 VAC, or 24 VDC

Configure

$1,176.70 
2106B1413
(1458)

HONEYWELL  2106B1413

Honeywell Sieger Sensepoint Gas Detector Transmitter for Ammonia (NH3) (0-50 ppm to 0-1000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,217.33 
PQD-4834-1/2
(6739)

PROSENSE  PQD-4834-1/2

Prosense PQD-4834 Gas Detector with Electrochemical sensor for Ammonia (NH3) with ranges 0-100ppm or 0-1000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,235.52 
1100ALD-109012/0300P-L0
(6908)

RC SYSTEMS  1100ALD-109012/0300P-L0

RC Systems SenSmart 1100 gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,314.28 
LBW-50-RLV
(914)

COOL AIR  LBW-50-RLV

Cool Air Ammonia Relief Line Vent Gas Detector LBW-RLV for continuos monitoring of Ammonia (NH3) 25-800ppm refrigeration gas emergency vent line headers. NEMA 4 weatherproof enclosure. 2 Alarm and 1 Auxiliary relays, 2 wires for power. 4 wires for control signals. 100 to 240VAC, 50/60 Hz, 16 VAC, or 24 VDC UL Listed

Configure

$1,332.50 
GG-NH3-0100
(2966)

CALIBRATION TECHNOLOGIES  GG-NH3-0100

CTI GasGuard NH3 Ammonia Electrochemical Sensor (0-100, 0-250, 0-500 or 0-1000 ppm) for gas leak detection in food processing areas, cold storage, compressor rooms and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,349.00 
GG-NH3-2
(2967)

CALIBRATION TECHNOLOGIES  GG-NH3-2

CTI GasGuard NH3-2% Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressor rooms, emergency shutdown, E-stop, heat treatment and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,394.00 
GG-VL2-NH3
(2970)

CALIBRATION TECHNOLOGIES  GG-VL2-NH3

CTI GasGuard NH3 Ammonia Vent Line 0-1% (0-10000 ppm) for gas leak detection in refrigeration system relief valves (outdoor installations only). 4-20 mA output, 24VDC power supply and NEMA 4X stainless enclosure.

Configure

$1,434.00 
100-0008-SS/100-0015-NH3
(4759)

ESP SAFETY  100-0008-SS/100-0015-NH3

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Ammonia (NH3) 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
41001AL-0-1015/0300P/L0
(7158)

RC SYSTEMS  41001AL-0-1015/0300P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,538.96 
51001AL-0-1015/0300P/L0
(7123)

RC SYSTEMS  51001AL-0-1015/0300P/L0

RC Systems SenSmart 5100 3-wire gas detector for Ammonia (NH3) 0-100 to 0-1000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class 1 Div 2 (Non-Incendive). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.