Gds Gmii-00-090-00/00-000-00/0-0 | Gds Gasmax | Transmitters | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GMII-00-090-00/00-000-00/0-0

GDS GMII-00-090-00/00-000-00/0-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GASMAX II 3-Wire Gas Detector Transmitter Only 4-20 mA input, 4-20 mA output with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

GMII-00-090-00/00-000-00/0-0   
Please Email us your request for quote   

Gas Range
2nd Input channel
Gas Range
Output Options
Enclosure
Tag
Remote JBox
MODBUS JBox
Duct Mount
Cal Marker

   2 Weeks  ]
251 Variants of base SKU / 30 Shown below

The GASMAX II gas monitor delivers the latest in toxic & combustible gas detection technology, reliability and ease of use.

Widest Variety of Available Sensors

Built-in dual channel electronics allow the GASMAX II to support any GDS Corp sensor or any combination of one toxic and one combustible (bridge-type) sensor. GDS Corp Smart Sensors enhance this capability by maintaining their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX II constantly tracks sensor performance and calculates an estimate of sensor life remaining.

Advanced User Interface

The highly visible backlit display and high intensity alarm LEDs constantly show alarm status, calibrated engineering values and programmable tag name; a trend screen shows alarm levels and the most recent 30 minute data values. An internal real-time clock and event log time-stamp calibration and alarm events for later review. A menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Flexible Output Options

In addition to standard dual 4-20mA current loop outputs, an optional dual isolated 4-20mA output board or an RS-485 two-wire MODBUS® interface with three 5A SPDT relays are available to communicate with controllers or drive local alarm indicators. When used with the C1 Protector controller’s MODBUS master port, multiple GASMAX II monitors can be daisy-chained up to 500m to minimize wiring.

Reliable

Available in both single and dual channel models, the GASMAX II is CSA and ATEX certified for use in Class I, Div 1 explosion proof installations. For low temperature applications, an Arctic Monitor option add thermostatically controlled heaters to enable operation as low as –55°C ambient.

FEATURES

  • CSA Certified for Class I, Div 1 explosion-proof installations
  • Monitor both toxic sensors and LEL with one detector
  • Graphic display shows values, units, trend graph, alarm levels
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Backlit display for better visibility in low light conditions
  • Options for 3x 5A alarm contacts, isolated 4-20mA and MODBUS®
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand

GASMAX II SPECIFICATIONS
Power Input: 10-30VDC at < 3 watts with relay board. Additional power (4W peak) required for Arctic Monitor option.
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and eunits.
Electrochemical Sensor Input Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors
Bridge Type Sensor Input Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead. Can be converted to 4-20mA input for use with GDS-49 or other standard 4-20mA source.
Standard Output Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional Output #1 Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC.
Optional Output #2 Three Form C Relays 5A @ 30VDC / 240VAC plus RS-485 2-wire MODBUS® slave interface
Temp -25°C to +65°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel opt
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP nstallations
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty 2 years from date of purchase on electronics and one year on sensors.

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
10-0232
(1571)

RC SYSTEMS  10-0232

RC Systems ST-48 Display/CPU front panel assembly board for series 2000/3000 gas detectors



$677.92 