Medc Pbibnnnn0dsnnn7r | Call Points | Atex Exia | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MEDC   PBIBNNNN0DSNNN7R

MEDC PBIBNNNN0DSNNN7R

ALARM SIGNAL DEVICES / ATEX EXIA
CALL POINTS

$559.15  [9 Weeks]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD, Ex ia IIC T4 Ga, Ex ia IIIC T135C Da. CUTR, Inmetro and CQST certifications also available.

PBIBNNNN0DSNNN7R   
559.15

Certification
Entry
Entry
Label
Voltage
Switch
Options
Options
Options
Terminals
Finish

   9 Weeks  ]
251 Variants of base SKU / 30 Shown

These manual fire alarm call points have been designed for use in hazardous locations and harsh environmental conditions. The GRP enclosures are suitable for use offshore or onshore, where lightweight combined with a high level of corrosion resistance is required.

FEATURES

  • Polyester enclosure – light, strong and not subject to corrosion.
  • 2 models:
    Breakglass.
    Pushbutton.
  • 4 basic versions available:
    (1) Explosion protected Exe (ATEX, Chinese [CQST],Brazilian [Inmetro])
    (2) Explosion protected Exi (ATEX, GOST ‘R’, GOST ‘K’, Chinese (CQST),
    Brazilian [Inmetro] or CSA),
    (3) Explosion protected: Class I, Div. 2, Groups A-D
    Class II, Div. 2, Groups F & G (PB only)
    Class I, Zone 2
    (4) Weatherproof & Dust-tight/UL ordinary locations.
  • In line and end of line resistors and/or zener diodes can be fitted.
  • Variety of colours available.
  • Up to 9 terminals available.
  • Lift flap available for extra protection against inadvertent operation.
  • Optional LED – this indicates that the unit has been operated – useful for testing purposes.
  • Earth continuity option for metal glands.
  • 1 or 2 changeover switches.
  • Captive cover screws.
  • SIL 2 Certified.
Pushbutton Model
  • Stayput as standard or self reset available.
  • Lift Flap as standard. (Not turn and push model).

Specification
Model: BGW & PBW *BGUL & PBUL BGE & PBE BGI & PBI
Protection: Weatherproof/dust proof Explosion Protected
Class I, Div 2
Class II, Div 2
Explosion Protected Exed (Increased Safety) Explosion Protected Exia (Intrinsically Safe)
Certification: Weatherproof/dust proof
IP66/IP67
UL Listed to Class I, Div 2, Groups A-D BGUL & PBUL Class II, Div 2, Groups F & G (PBUL only) Listing No. E186629
UL listed for ordinary locations Listing No. S8117
*Refer to UL data sheet at rear of catalogue for complete information
ATEX approved Ex II 2GD BAS02ATEX2105X (PB only)
ATEX approved Ex II 2G BAS02ATEX2105X (BG only)
Exed IICT6 (switch only)
Exedm IICT4 (other versions)
CENELEC EN50014
EN50019
EN50018
EN50028
Suitable for use in Zones 1 & 2
Chinese Certification (PBE & BGE):†
CQST – Exed IIC T6 (switch only)
Exedm IIC T4 (other versions)
GOST ‘R’ Certification (PBE & BGE):
Exedm IIC T6
Exedm IIC T4 (other versions)
Russian Fire Approved
Brazilian (Inmetro) Certification:
BR-Ex emd IIC T4 or BR-Ex ed IIC T6
SIL 2 Certification to 61508.
Cert. No. Sira 11013 (BGE only).
American Bureau of Shipping Type Approval BGE only
ATEX approved Ex II 1GD Baseefa 03ATEX0084X (PB only)
ATEX approved Ex II 1G Baseefa 03ATEX0084X (BG only)
Exia IIC T4
CENELEC EN50014
CENELEC EN50020
Suitable for use in Zones 0, 1 & 2
CSA Certification to C22.2 (PBI only):
Nos.0-M, 0.4-M, 14-M, 25, 30-M, 94, 142-M1987, 157-M1987, 157-92, Enclosure Type 4. T4A
Class I Groups A, B, C & D
Cert. No. 79120
GOST ‘R’ Certification (PBI & BGI): Exia IIC T4 Russian Fire Approved
GOST ‘K’ Certification (PBI only):
Exia IIC T4
Chinese Certification (PBI & BGI):
CQST – Exia IIC T4
Brazilian (Inmetro) Certification:
BR-Ex ia IIC T4
American Bureau of Shipping Type Approval
Voltage: Up to 254V Up to 240V Up to 250V Up to 28V (IS)
Certified Temp: –40°C to +55°C
Weatherproof
–25°C to +55°C (PBUL)
–25°C to +55°C (BGUL)
UL Version
–20°C to +50°C ATEX/CENELEC –40°C to +70°C (PBI)
ATEX/CENELEC –40°C to +50°C (BGI)
CSA –50°C to +40°C (PBI only)
Switch Ratings: (1 or 2 changeover switches fitted) d.c. - 0-30v 5A (resistive) or 3A (inductive)
30-50 1A resistive or inductive
a.c. - 0-254V 5A resistive or inductive
NOT APPLICABLE

Note: UL versions Max Rating 240VAC, 3A

Specification
Material: Anti static U.V. resistant glass reinforced polyester.
Finish: Red painted finish as standard or to Customer specification.
British Standard for Call Points: BS 5839 : Part 2 : 1983 (BG).
Weight: 1.2 kg. (Varies with model & entries).
Ingress Protection: IP66 & IP67.
Entries: Up to 4 entries, M16 or M20 top and bottom (1/2" NPT available on UL version).
Terminals: 6 x 2.5mm2 – standard (BGUL only).
7 x 2.5mm2 – standard.
9 x 2.5mm2 optional – up to 60V only.
Risistors & Diodest: Various configurations available on versions up to 24V and all "IS" versions. (Minimum Resistor value 100ΩPBE/BGE, 470ΩPBI/BGI).
Earth Continuity: Internal & external earth continuity is provided via an optional earth plate.
LED Indication: A high intensity red LED can be fitted as an optional extra to indicate operation on versions up to 24V and all "IS" versions.
Labels: BG Glass label - reads either
(1) Fire Break glass – press here
(2) Break glass – press her
(3) Worded to customer requirements.
PB & BG Duty label - worded to customer requirements. Rivetted on.
PB & BG Tag label - worded to customer requirements. Screwed on.
Export Info
Made inUnited Kingdom

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
NBG-12
(6824)

NOTIFIER  NBG-12

NOTIFIER by Honeywell NBG-12 Non-Coded Conventional Manual Fire Alarm Pull Station that initiates an input signal for any conventional control panel (FACP). Single or Dual Action Versions. UL, CSFM and FM Approvals.

NBG-12LR
(5811)

NOTIFIER  NBG-12LR

Notifier NBG-12LR Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual-action agent release station. FM Approved and cUL Listed.

4099-9004
(6848)

TYCO  4099-9004

Tyco Simplex 4099-9004 addressable manual station with communication module for IDNet or MAPNET II. LED indicator. Breakglass or push operation. Surface or Flush mounting. NEMA 1. Complies with ADA requirements. UL listed.

Configure

$67.52 
NBG-12LX
(2042)

NOTIFIER  NBG-12LX

NOTIFIER by Honeywell NBG-12LX Addressable Manual Pull Station, dual-action (requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel.

NBG-12LOB
(4603)

NOTIFIER  NBG-12LOB

Notifier NBG-12LOB Pull Station which provides a Fire Alarm Control Panel (FACP) with a single alarm input signal. Includes dual action operation, Key-Lock Reset function, outdoor-use gasket and sealed switch. UL Listed.



 
NBG-12LRA
(4142)

NOTIFIER  NBG-12LRA

Notifier NBG-12LRA Agent Release Station for use with Notifier Fire Alarm Control Panels. Dual action operation. Abort switch. Power-on and released indication. FM Approved and cUL Listed.

BG3W1NNN_BR
(1587)

MEDC  BG3W1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. Weatherproof. IP66 and IP67.

Configure

$193.80 
IS-CP4A-BG-ST-NF-NL-RD
(4080)

E2S  IS-CP4A-BG-ST-NF-NL-RD

E2S IS-CP4A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PT-ST-NL-RD
(4082)

E2S  IS-CP4A-PT-ST-NL-RD

E2S IS-CP4A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

IS-CP4A-PB-ST-NL-RD
(4081)

E2S  IS-CP4A-PB-ST-NL-RD

E2S IS-CP4A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 0, 1, 2, 21 & 22. 30V. LM6 aluminium enclosure. IP66. ATEX, IECEx and GOST-R certified.

BExCP3A-BG-ST-NF-NL-RD
(4083)

E2S  BExCP3A-BG-ST-NF-NL-RD

E2S BExCP3A-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3B-BG-ST-NF-NL-RD-06
(5136)

E2S  BExCP3B-BG-ST-NF-NL-RD-06

E2S BExCP3B-BG Break Glass Manual Call Point for alarm systems in Zones 1, 2, 21 & 22. B type (choice of end of line devices). LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BG2WNN1_NR
(1586)

MEDC  BG2WNN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. Weatherproof. IP66 and IP67.

Configure

$324.48 
BG3I1NNN_BR
(4152)

MEDC  BG3I1NNNBR

MEDC BG3 Manual call point with GRP enclosure. Designed in accordance with thelatest draft European Call Point Standard. ATEX approved Ex II 1G. IP66 and IP67.

Configure

$328.96 
GNEXCP6B-BG-SNSNNRD06
(6443)

E2S  GNEXCP6B-BG-SNSNNRD06

E2S GNExCP6B-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6A-BG-SNNNRD
(4086)

E2S  GNEXCP6A-BG-SNNNRD

E2S GNExCP6A-BG Break Glass Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

BG2EDC1_NR
(4150)

MEDC  BG2EDC1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. DC or AC Version. EExed IIC T6 (T4 if resistors or diode fitted) ATEX Approved Ex II 2G. IP66 and IP67.

Configure

$360.46 
BG2INN1_NR
(4151)

MEDC  BG2INN1NR

MEDC BG2 Manual call point with GRP enclosure. Designed for use in flammableatmospheres and harsh environmental conditions. EExia IIC T4, ATEX Approved Ex II 1G. IP66 and IP67.

Configure

$378.49 
BExCP3B-PT-ST-NL-RD-06
(5138)

E2S  BExCP3B-PT-ST-NL-RD-06

E2S BExCP3B-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. B type (choose of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BExCP3A-PT-ST-NL-RD
(4085)

E2S  BExCP3A-PT-ST-NL-RD

E2S BExCP3A-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. A type (no end of line devices). 250VAC or 50VDC. LM6 aluminium enclosure. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

Page: 1 | 2 | 3 | All