Gds Gds-ir-1-110-0 | Lel Infrared | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GDS-IR-1-110-0

GDS GDS-IR-1-110-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GDS-IR Infrared Remote Gas Detector Transmitter with Stainless steel sensor head configured for Combustibles LEL (Specify), 3-Wire output 4-20 mA transmitter, Explosion Proof (XP) Class I, Div 1 SIL-2 Rated. Suitable for applications in the harshest of environments. Available gases: Methane (CH4), Propane (C3H8), Isobutane (C4H10), Pentane (C5H12), Cyclopentane (C5H10), n-Butane (C4H10), Ethanol (C2H6O), Methanol (CH4O), Hexane (C6H14), Jet-A, Diesel and Gasoline.

GDS-IR-1-110-0   
Please Email us your request for quote   

Sensor Head
Sensor Type
Options
Rain Shield
Enclosure
Tag

 3 Weeks  ]


The GDS-IR Infrared Gas Sensor uses proven, reliable infrared sensing technology to detect dangerous levels of carbon dioxide or explosive levels of methane, propane and other hydrocarbons. The GDS-IR sensor is CSA certified for use in Class 1 Division 1 explosive environ- ments and is CSA performance tested.

Advanced Infrared Technology

The GDS-IR infrared combustible gas sensor offers low total cost of ownership and a seventeen-year MTBF rating. Designed for especially harsh environments, the GDS-IR is virtually maintenance-free and immune to poisoning or etching by any known gas. The sensor element features a self-compensating optical bench, heated optical chamber and fault indication for all failure modes. The optical path can be easily opened for cleaning.

No periodic span calibrations are required. On initial setup and after each cleaning, a simple ‘auto zero’ procedure is used to establish proper operating conditions.

Flexibility

The GDS-IR can be calibrated to read a wide range of combustible hydrocarbons, including methane, propane, hexane, pentane, ethanol, Jet-A, isobutane, propylene and isoproply alcohol, as well as carbon dioxide to 5% by volume. GDS-IR sensors are factory programmed and calibrated when shipped and can be field programmed for alternate response curves. Both LEL and % by volume ranges are available.

GASMAX + GDS-IR Combo

When combined with the GASMAX II monitor, the duo provides local display, 4-20mA output with diagnostics, optional second electrochemical sensor, isolated 4-20mA outputs or MODBUS slave interface with programmable relays.

Reliable Detection

The GDS-IR is manufactured in the USA and includes a five year operational warranty. Applications include refineries, onshore and offshore drilling platforms, fuel loading docks, biogas processing, breweries, wastewater treatment facilities and natural gas storage and distribution.

Calibration Port

It comes with a barb fitting on the end of the GDS-IR, just remove the cap and connect the Tygon calibration tubing.

FEATURES

  • Suitable for use in SIL-2 rated safety systems
  • High speed response for critical applications (T50 less than 3 sec)
  • 5 Year Warranty and long life lowers total cost of ownership
  • 12 Year Warranty on infrared radiation source
  • Rugged stainless steel construction with no moving parts
  • Heated optical chamber maintains accuracy in cold conditions
  • Operates in constant hydrocarbon and anaerobic atmosphers
  • Ten discrete fault indication values for all failure states
  • Straight line optical path eliminates need for mirrors
  • Managed power-up delay reduces initial load on power supply
  • Industry standard 4-20mA current loop calibrated output
  • Multiple gas calibration curves for %LEL and % by volume
  • CSA Certified C22.2 No. 152-M1984 Performance Tested
  • Manufactured in USA

GDS IR SPECIFICATIONS
Power Input: 18-30VDC at 5 watts (typical). Delayed IR source turn-on minimizes inrush power for distributed systems.
Max Current Average: 210 mA, peak 400 mA at 24VDC
Display None.
Sensor Technology Reliable infrared sensing technology with patented self-compensating optics and easy-to-clean
Standard Output Standard 3-wire 4-20mA current source. Max loop R is 1000 ohms with nominal 24VDC power supply
Output Alarm Conditions Discrete 4-20mA output levels indicate general fault, reference & optics fault, warm-up, zero drift fault, calibration fault, zero and span set and overrange conditions.
Accuracy ± 3% LEL, 0-50% LEL
± 5% LEL, 51 - 100% LEL
Response Time T50 < 3 seconds; T90 < 5 seconds
Temp -40°C to +70°C at 0 to 99% RH
Housing #316 Stainless Steel
Dimensions with j-box Width 5.4” (137 mm), Height with junction box 12.75” (324 mm), Depth 3.5” (89 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D
C22.2 No.152-M1984 (R1997) for performance
Warranty 5 years from date of purchase
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder.

20-0100
(1739)

GDS  20-0100

GDS Remote XP junction box for GDS-IR with zero-set pushbutton



 
1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

10-0271
(561)

GDS  10-0271

Sample flow cell assembly for GDS-IR



 
(1740)

GDS  12-0251

Programming adapter for GDS-IR



 
> LEL INFRARED :    24 Items found.
P-3033
(6722)

PROSENSE  P-3033

Prosense P-XY35 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$797.94 
PQN-3033-1/2
(6946)

PROSENSE  PQN-3033-1/2

Prosense PQN-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$978.12 
PQD-3033-1/2
(6719)

PROSENSE  PQD-3033-1/2

Prosense PQD-XY33 Gas Detector with Infrared sensor for Hydrocarbons (Methane, LPG, Propane, Hydrogen, Gasoline, Pentane, Hexane, nButane) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$1,132.56 
SPXCDULNRX
(659)

HONEYWELL  SPXCDULNRX

Honeywell XCD Sensepoint Gas Detector, Methane (Natural Gas) (CH4) Infrared Sensor combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,413.89 
100-0008-SS/100-0015-C1
(4756)

ESP SAFETY  100-0008-SS/100-0015-C1

ESP Safety Vector 2-channel gas detector controller with smart Infrared IR Plug-In sensor included to detect Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
100-0001-M11-SS-C1
(4722)

ESP SAFETY  100-0001-M11-SS-C1

ESP Safety SGOES Infrared Gas Detector for measurement of hydrocarbon gases, Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Gasoline, Diesel, JP8, Acetone, Benzene, Butadiene, Butanol 0-100% LEL and others. Factory calibrated at 0%, 20%, 50%, and 95% LEL. Analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 3 relays. Includes protective weather cover and mounting hardware. IP66. SIL2 Rated. FM, ABS, IECEx, CE and CSA, Class I Division 1 Approved. Stainless steel construction. T90 response time= < 5 seconds (methane).

Configure

$1,440.00 
OI-6000-IR-LEL-X-R_-DC-C
(6833)

OTIS  OI-6000-IR-LEL-X-R-DC-C

Otis Instruments OI-6000 Gas Leak Detector with infrared sensor for Combustibles 0-100% LEL. Non explosion proof. Wired power (3-Wire) (12 to 35 VDC) with 4-20 mA analog, RS-485 Modbus and 2 relay outputs. 3 Push-Button Interface. IP 66/67. Optional radio. UL Approved.

53001AL-0-9050/100P/L0
(7136)

RC SYSTEMS  53001AL-0-9050/100P/L0

RC Systems SenSmart 5300 3-wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,809.09 
SPXCDULNPX
(660)

HONEYWELL  SPXCDULNPX

Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,813.32 
967-215520-100
(2133)

DETCON  967-215520-100

Detcon IR-700-CH Infrared Smart Combustible Sensor Assembly. Designed to detect hydrocarbon gases 0-100% LEL. 4-20 mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water-Proof, Corrosion-Proof and Vibration-Proof. Optional aluminum or stainless steel junction box. Gases: Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, Gasoline Vapor, Diesel Fuel Vapor, Jet Fuel Vapor

2108N4000N
(3414)

HONEYWELL  2108N4000N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, ATEX/IECEx approved (Also available UL/INMETRO and CSA). Optional remote gassing cell.

Configure

$2,123.32 
2108N4100N
(1676)

HONEYWELL  2108N4100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration (Methane, Natural Gas, Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit) with dust barrier, weather housing, deluge/heat shade, configured as current source output, UL/INMETRO approved (Also available ATEX and CSA). Optional remote gassing cell.

Configure

$2,123.32 
33001AL-0-9050/100P/L0
(6898)

RC SYSTEMS  33001AL-0-9050/100P/L0

RC Systems SenSmart 3300 3 wire gas detector with infrared (IR) sensor for Hydrocarbons 0-100% LEL or %Vol for Natural Gas/Methane (CH4), Ethane (C2H6), Propane (C3H8), Butane (C4H10), Pentane (C5H12), Hexane (C6H14), Ethanol, Ethylene, Ethylene Oxide, Propylene, Toluene, Vinyl Acetate, Nitrous Oxide with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Division 1 (Explosion Proof).

Configure

$2,181.82 
PIRECLA11A1BT2
(7027)

DET-TRONICS  PIRECLA11A1BT2

Det-tronics PointWatch Eclipse PIRECL Infrared Gas Detector for detection of Hydrocarbons (methane, propane, ethylene, butane) 0 to 100% LFL. Diffusion based. 4-20 mA signal with HART and RS-485 serial communication. Optional relay output. Explosion-proof and stainless steel housing. 24 Vdc. Certified for use in Class I, Divisions 1 and 2. FM, CSA, ATEX, IECEx, DNV/MED, and INMETRO certifications.

XNXUTAVNNIF1
(1225)

HONEYWELL  XNXUTAVNNIF1

Honeywell XNX Universal Gas Detector Transmitter with MPD-AMIF1 IR Infrared sensor for %LEL Propane (C3H8) 0-100% LEL or Methane (CH4) 0-100% LEL and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,276.97 
XNXUTAVNNIV1
(2141)

HONEYWELL  XNXUTAVNNIV1

Honeywell XNX Universal Gas Detector Transmitter including MPD-AM1V1 IR Infrared sensor combustible 0-5% Vol 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). Backlit LCD Display, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$2,380.43 
2108N5100N
(1965)

HONEYWELL  2108N5100N

Honeywell Optima Plus advanced stainless steel Point Infrared Hydrocarbon Gas Detector LEL available for over 100 gas and vapour calibrations. 4-channel (dual compensated) optics-block, 3-Wire 4-20mA source, optional HART. Hydrocarbon calibration (Methane (Natural Gas), Propane, etc.) combustible 0-100% LEL (Lower Explosive Limit), for use in remote sampling systems, includes flow housing and remote gassing cell, configured as current source output.

Configure

$2,482.01 
GD10-P00-17DG-0BH
(1868)

SIMTRONICS  GD10-P00-17DG-0BH

Simrad GD10P IR Point Gas Detector for combustible gases: Methane (CH4) , Ethylene (C2H4), Propane (C3H8), Acetylene, Butane and others on offshore installations. 4-20 mA output with HART. 24 VDC. Available Approvals: UL Class I Division 1, ATEX, CSA/US, IECEx, INMETRO, ABS, SIL and MED.

10-0498/100L
(7183)

RC SYSTEMS  10-0498/100L

RC Systems SenSmart 1300M Infrared IR gas detector transmitter for Hydrocarbons 0-100% LEL or %Vol with high performance harsh environment infrared Millenium sensor-transmitter, 4-20mA output, 10-30 VDC, Stainless Steel casing. CSA certified for Class 1 Div 1 (Explosion Proof). Available gases: Acetylene, Ethane, Ethanol, Ethylene Oxide, Diesel, Gasoline, Hexane, Jet Fuel, JP4, JP5, JP8, Methane, Methanol, n-Butane, Pentane, Propane, Propylene and Toluene.

Configure

$3,422.07 
XNXUTAINNNNN-2108N4110
(851)

HONEYWELL  XNXUTAINNNNN-2108N4110

Honeywell XNX Universal Gas Detector Transmitter with Optima Plus Infrared Hydrocarbon Gas Detector combustible 0-100% LEL (Lower Explosive Limit) and aluminum housing. The XNX is compatible with all Honeywell gas sensing technologies. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2 . Available for over 100 gas and vapour calibrations.

Configure

$3,478.59 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.