Gds Gmii-00-000-00/01-071-06/0-0 | Lel Catalytic Bead | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

GDS   GMII-00-000-00/01-071-06/0-0

GDS GMII-00-000-00/01-071-06/0-0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured for Catalytic Bead sensor for Combustibles LEL (specify gas) with range 0-100% LEL (Lower Explosive Limit), 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Available calibrated to Methane (Natural Gas), Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others. CSA Certified for Class I, Div 1.

Inquiry

The GASMAX II gas monitor delivers the latest in toxic & combustible gas detection technology, reliability and ease of use.

Widest Variety of Available Sensors

Built-in dual channel electronics allow the GASMAX II to support any GDS Corp sensor or any combination of one toxic and one combustible (bridge-type) sensor. GDS Corp Smart Sensors enhance this capability by maintaining their own record of serial number, born-on date, initial calibration values, engineering units and more. Using this information, the GASMAX II constantly tracks sensor performance and calculates an estimate of sensor life remaining.

Advanced User Interface

The highly visible backlit display and high intensity alarm LEDs constantly show alarm status, calibrated engineering values and programmable tag name; a trend screen shows alarm levels and the most recent 30 minute data values. An internal real-time clock and event log time-stamp calibration and alarm events for later review. A menu-driven operator interface using magnetic keys eliminates all analog potentiometers and allows complete setup and calibration without hazardous area declassification.

Flexible Output Options

In addition to standard dual 4-20mA current loop outputs, an optional dual isolated 4-20mA output board or an RS-485 two-wire MODBUS® interface with three 5A SPDT relays are available to communicate with controllers or drive local alarm indicators. When used with the C1 Protector controller’s MODBUS master port, multiple GASMAX II monitors can be daisy-chained up to 500m to minimize wiring.

Reliable

Available in both single and dual channel models, the GASMAX II is CSA and ATEX certified for use in Class I, Div 1 explosion proof installations. For low temperature applications, an Arctic Monitor option add thermostatically controlled heaters to enable operation as low as –55°C ambient.

FEATURES

  • CSA Certified for Class I, Div 1 explosion-proof installations
  • Monitor both toxic sensors and LEL with one detector
  • Graphic display shows values, units, trend graph, alarm levels
  • Supports both local and remote sensors for easy installation
  • Non-intrusive, prompted calibration with programmable cal gas
  • Power-up and post-calibration delays eliminate false alarms
  • Backlit display for better visibility in low light conditions
  • Options for 3x 5A alarm contacts, isolated 4-20mA and MODBUS®
  • Security settings to lock critical parameters
  • Auto-recognition of Smart Sensors uploads calibration data & more
  • Fault supervision circuitry detects failed sensor & transmits warning
  • Setup in hazardous area requires only simple magnetic wand

GASMAX II SPECIFICATIONS
Power Input: 10-30VDC at < 3 watts with relay board. Additional power (4W peak) required for Arctic Monitor option.
Display Backlit 64 x 128 pixel LCD with 30-minute trend, bargraph and eunits.
Electrochemical Sensor Input Channel 1 accepts microamp-level signals from GDS Corp toxic & oxygen deficiency sensors
Bridge Type Sensor Input Channel 2 provides adjustable excitation voltage for SmartIR, PID and catalytic bead. Can be converted to 4-20mA input for use with GDS-49 or other standard 4-20mA source.
Standard Output Standard dual 3-wire 4-20mA current source. Max loop R is 750 ohms with nominal 24VDC power supply
Optional Output #1 Dual 1500CMV isolated 4-20mA current source. Max loop R is 650 ohms with nominal 24VDC.
Optional Output #2 Three Form C Relays 5A @ 30VDC / 240VAC plus RS-485 2-wire MODBUS® slave interface
Temp -25°C to +65°C (see sensor limitations)
Housing Aluminum housing with epoxy paint standard; #316 stainless steel opt
Dimensions Width 5.4” (137 mm), Height 8” (203 mm), Depth 5” (127 mm) Shipping weight 6.5 pounds (3 kg)
Approvals CSA Certified for Class I, Div 1, Grps B, C, D. Suitable for XP nstallations
ATEX Certified EX II 2 G EEx d IIB + H2 T5
Warranty 2 years from date of purchase on electronics and one year on sensors.


Gas / Vapor LEL [Low Explosive Level] Relative Response
(with respect to Methane)
Acetic Acid 5.4% 0.20
Acetone 2.6% 0.35
Ammonia 15% 0.65
Benzene 1.3% 0.35
Butyl Acetate 1.4% 0.30
Cyclo-hexane 1.3% 0.45
Cyclo-pentane 1.4% 0.5
Decane 0.75% 0.20
Dioxane 2.0% 0.50
Ethane 3.0% 0.85
Ethanol 3.3% 0.45
Ethyl Acetate 2.2% 0.35
Ethylene 2.7% 0.65
Hydrogen 4.0% 0.95%
Iso-Butane 1.8% 0.55
Iso-Butyl Alcohol 1.7% 0.30
Iso-Butyl Methyl Ketone 1.2% 0.25
Iso-Octane 0.95% 0.35
Iso-Pentane 1.4% 0.45
Iso-Propyl Alcohol 2.2% 0.35
Methane 5.0% 1.0
Methanol 6.7% 0.70
Methyl Ethyl Ketone (MEK) 1.9% 0.35
Nonane 0.85% 0.25
Propane 2.1% 0.60
Propylene 2.4% 0.70
Styrene Monomer 1.1% 0.30
Toluene 1.2% 0.40
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000
> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
10-0203
(259)

GDS  10-0203

GDS Sensor calibration cup for stainless steel / aluminum sensor heads



 
1200-0267
(3192)

GDS  1200-0267

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 50% LEL. Balance Air. 103DS Stainless Steel Cylinder.

1200-0768
(3191)

GDS  1200-0768

GDS Gas Detector Calibration Gas Cylinder Methane (CH4) 25% LEL. Balance Air. 103L Aluminium Cylinder.

10-9571-R06
(1738)

GDS  10-9571-R06

Catalytic Smart LEL sensor configured for Other Gas (Specify) with range combustible 0-100% LEL (Lower Explosive Limit). Can be calibrated to Ethane, Ethylene, Hydrogen, Butane, Pentane, IPA, Methanol, MEK, Propane, Propylene, Pentane and many others. For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
10-9570-R06
(342)

GDS  10-9570-R06

Catalytic Smart LEL sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit).



 
1200-0587
(3124)

GDS  1200-0587

GDS Gas Detector Calibration Gas Kit Methane (CH4) 25% LEL. Balance Air. Kit includes a 103L Aluminium Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

1200-0522
(3125)

GDS  1200-0522

GDS Gas Detector Calibration Gas Kit Methane (CH4) 50% LEL. Balance Air. Kit includes a 103DS Stainless Steel Cylinder of Calibration Gas, fixed flow regulator, tubing, and carrying case. Optional Zero Air Cylinder.

10-9551-R06
(338)

GDS  10-9551-R06

Infrared Smart IR LEL Sensor with range 0-100% LEL (Lower Explosive Limit) for combustibles (specify). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
10-9550-R06
(262)

GDS  10-9550-R06

Infrared Smart IR LEL Sensor configured for Methane with range combustible 0-100% LEL (Lower Explosive Limit). For GDS GASMAX EC, GASMAX II, TRANSMAX EC, TRANSMAX II with stainless steel sensor head and GDS GASMAX ECx, GASMAX IIx, GDS-48, GDS-49, GDS-58XP.



 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
> LEL CATALYTIC BEAD :    28 Items found.
GD-2A
(650)

MACURCO  GD-2A

MACURCO Combustible Gas Detector low voltage all-electronic monitor engineered to detect heating type gases, including methane (natural gas) and propane(bottled gas). 12-24 VAC or VDC input. SPDT alarm and NC trouble relays. Listed to UL Standard 2075. CSFM Approved.



$117.91 
GD-2B
(2047)

MACURCO  GD-2B

Macurco GD-2B Gas Detector for combustibles (heating type gases). Low voltage and designed for connection to Fire Alarm/Burglary Control Panels. 9-32 VDC or 12-24 VAC input. Meets UL 2075 standard. Alarm, trouble relays and 85dB buzzer.



$117.91 
PC3-3012
(6801)

PROSENSE  PC3-3012

Prosense PC3-XY12 Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, n-Butane, Propane, Hydrogen or Pentane) with range 0-100% LEL. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$231.66 
P-3012PE
(6799)

PROSENSE  P-3012PE

Prosense P-XY12PE Gas Detector with Catalytic Bead sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog output. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$308.88 
P-3012PEK
(6800)

PROSENSE  P-3012PEK

Prosense P-XY12PEK Gas Detector with Catalytic Bead and Motion sensor for Hydrocarbons (LPG, Methane, Petrol Vapour, n-Butane, Propane or Hydrogen) with range 0-100% LEL. Ex-proof housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. ATEX/IECEx approval. IP65.

Configure

$308.88 
P-3035
(6721)

PROSENSE  P-3035

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$437.58 
P-5535
(6774)

PROSENSE  P-5535

Prosense P-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$437.58 
GD-6
(1234)

MACURCO  GD-6

MACURCO GD-6 low voltage Gas Detector, Controller and Transducer for Combustibles 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$481.90 
SPSTAXF1
(1475)

HONEYWELL  SPSTAXF1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Methane (CH4) 0-100% LEL (combustibles) complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 3 wire bridge output. ATEX Approved. Poison resistant catalytic bead.

Configure

$482.11 
GD-12
(3416)

MACURCO  GD-12

MACURCO GD-12 line voltage Gas Detector, controller and transducer for Combustibles (EX) 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$494.01 
2106B1200
(1469)

HONEYWELL  2106B1200

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. ATEX/IECEx Certified.

Configure

$575.52 
PQN-3035-1/2
(6947)

PROSENSE  PQN-3035-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$617.76 
PQN-5535-1/2
(6950)

PROSENSE  PQN-5535-1/2

Prosense PQN-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$617.76 
PQD-3035-1/2
(6718)

PROSENSE  PQD-3035-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Methane, Propane, Butane, Hydrogen, Gasoline, Diesel, JP8, Ammonia, Pentane, Hexane, Alcohols, Benzene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$772.20 
PQD-5535-1/2
(6736)

PROSENSE  PQD-5535-1/2

Prosense PQD-XY35 Gas Detector with Pellistor (Catalytic Bead) sensor for Hydrocarbons (Ethane, Butyl Alcohol, Styrene, Propylene, Xylene, Benzene, Vinyl Acetate, JP8 Fuel, Diesel, Formaldehyde, Nonane, Acetaldehyde, Isobutylene and others) with range 0-100% LEL. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$772.20 
2106B2310
(1640)

HONEYWELL  2106B2310

Honeywell Sieger Sensepoint Gas Detector Transmitter with LEL Sensor for explosives/combustibles 0-100% LEL 3-wire mv Bridge output. High Temperature (150°C with 3rd party performance approval) ATEX

Configure

$855.75 
OI-6000-CB2-LEL-X-X-O
(6836)

OTIS  OI-6000-CB2-LEL-X-X-O

Otis Instruments OI-6000 Gas Leak Detector with catalytic bead sensor for Combustibles 0-100 % LEL. Explosion Proof Wired power (3-Wire). (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. 3 Push-Button Interface. IP 66/67. Optional alarm relays and Radio. CSA Approved for Class I Div 1. ATEX Zone 1 and IECEx Certified.

GG-LEL2-CH4
(4137)

CALIBRATION TECHNOLOGIES  GG-LEL2-CH4

CTI GG-LEL2 Combustible Catalytic Bead Gas Detector Transmitter (0-100% LEL) for Methane (CH4), Hydrogen (H2), Propane (C3H8), N-Butane (C4H10), Ethane (C2H6), Ethylene (C2H4), N-hexane (C6H14) or N-pentane (C5H12). 4-20 mA output, 24VDC power supply. Explosion proof Copper-free aluminum enclosure for Class l, Div 1, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved. Optional Relay output.

Configure

$1,145.00 
1200ALD-109070/100P-L0
(6903)

RC SYSTEMS  1200ALD-109070/100P-L0

RC Systems SenSmart 1200 gas detector for Hydrocarbons and Hydrogen, Catalytic Bead sensor (acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, isopropyl alcohol, methane, pentane, propane, propene or propylene) 0-100% LEL with 'ST-48' smart transmitter. 3-Wire Bridge Output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,218.18 
SPXCDULNFX
(658)

HONEYWELL  SPXCDULNFX

Honeywell XCD Sensepoint Gas Detector, CATALYTIC BEAD combustible 0-100% LEL (Lower Explosive Limit) Methane CH4 (LNG-natural gas), Propane C3H8 (LPG), Butane C4H10, Pentane, Hexane, Ethanol, Hydrogen with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66, 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay and 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%, can be calibrated to several other combustible gases. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,373.95 
Page: 1 | 2 | All