Detcon 966-014520-100 | Hydrogen Sulfide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

DETCON   966-014520-100

DETCON 966-014520-100
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Detcon TP-624D Hydrogen Sulfide (H2S) 0-100ppm Smart Sensor with solid state metal oxide semiconductor technology. Includes MOS detector in stainless steel housing, base connector board, explosion proof enclosure, splashguard, 4-20 mA output, RS-485 serial communication and 3 alarm relays. IP66. ATEX and CSA approval for Class I, Division 1, Groups B, C & D.

966-014520-100   
Please Email us your request for quote   

Junction Box
Options

   3 Weeks  ]
4 Variants of base SKU

Detcon Model TP-624D is a “Smart” gas detection sensor designed to detect and monitor H2S in air over the range of 0-100 ppm using a proprietary solid state metal oxide semiconductor technology. This innovative design offers several advantages including longer sensor life and better temperature and humidity performance.

Model TP-624D features Detcon’s MicroSafeTM intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor transmitter features an advanced universal design that fits all existing Detcon MOS H2S sensors dating back more than 20 years. The sensor assembly includes a MOS detector in stainless steel housing, a base connector board, an explosion proof enclosure (available in aluminum or stainless steel), a plug-in control transmitter circuit, and a splashguard with integral cal port. The packaging is Explosion Proof (Class I, Division 1, Groups B, C, D).

Model TP-624D is equiped with a standard analog 4-20 mA current signal equivalent to the sensor range of detection, RS-485 serial communications port, 3 alarm relays, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault, alarm, and calibration status. Detcon’s solid state MOS sensor is supported by an industry leading 10-year conditional warranty.

Features
  • cCSAus approved for Class I, Division 1, Groups B, C, & D
  • Transmitter design fits all existing Detcon MOS H2S sensors dating back 20 years
  • Compatible with PLCs, SCADA, DCS, via 0-20 mA, and /or RS-485, and/ or alarm relays
  • Sensor status ad parameters accessible via RS-485 (Modbus)
  • Menu programmable relays standard (two alarms plus fault)
  • Simple menu driven calibration- less than 3 minutes
  • LED display and LED indicators for FAULT and CAL ststus
  • Plug-in field-replaceable transmitter
  • Response similar to electrochemical sensor:T50 <30sec., T80 <60 sec.
  • 10 year conditional sensor warranty
  • Direct response constant temperature control
  • Withstands exposure to high range concentrations of H2S and other acid gases
  • Impervious to high moisture environments in both powered and non-powered mode
  • Extensive Fault diagnostics
Applications
  • Oil and Gas Drilling Rigs
  • Oil and Gas Production Sites
  • Refining and Petrochemical
  • Pulp and Paper Mills
  • Waste Water Treatment Plants

System Specifications
Sensor TypeContinuous diffusion/adsorption
CHEMFET Solid State Metal Oxide Semiconductor
Sensor Life5 to 10 years typical
Measurement Range0-20 ppm, 0-50 ppm, 0-100 ppm
Accuracy/Repeatability±10% of reading or ±2 ppm (greater of )
Response/Clearing TimeT50 <30 seconds; T90 <60 seconds
OutputsLinear 4-20 mA DC
RS-485 MODBUS-RTU
3 Relays (alarm 1, alarm 2, & fault)
Contacts rated 5 amps
Electrical ClassificationExplosion proof
CSAuS
Class I, Division 1, Groups B, C, D (Tamb = -25°C to +40°C)
Class I, Zone 1, Group IIB+H2
cCSA
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +40°C)
Class I, Zone 1, Group IIB+H2
ATEX
Ex d IIB+H2 T4 (Tamb = -40°C to +60°C)
Safety ApprovalscCSAus
ATEX
CE Marking
SIL2 FMEDA Rating
Ingress ProtectionNEMA 4X, IP66
WarrantyPlug-in detector - 10 year conditional
Transmitter - 2 Years
Environmental Specifications
Operating Temperature Range-40°C to +40°C; -40°F to 104°F (CANADA)
-25°C to +40°C; -13°F to 104°F (USA)
Storage Temperature Range-35°C to +55°C; -31°F to +131°F
Operating Humidity Range5-100% RH non-condensing
Operating Pressure RangeAtmospheric ±10%
Mechnanical Specifications
Dimensions10”H (including splashguard) x 6.1”W x 4.3”D
254mmH x 155mmW x 109mmD
Mounting holes (J-box) 5.5”; 140mm center to center
Weight6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input12-28 VDC
Power ConsumptionNormal operation = 68mA (<1.7 watt)
Maximum = 87mA (2 watts)
RFI/EMI ProtectionComplies with EN 50270
Analog OutputLinear 4-20mA DC: (1,000 ohms max loop load @ 24VDC)
0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Serial RS-485 OutputRS-485 ModbusTM RTU
Baud Rate9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
4 LEDs for Alarm 1, Alarm 2, Fault, and Calibration
Relay OutputsAlarm 1, Alarm 2, and Fault
5A @ 250VAC
5A @ 30VDC
Faults MonitoredHeater, Loop, Input Voltage, Sensor, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair shielded cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring, EMI/RFI Immunity
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    1 Items found.
399-800000-000
(6202)

DETCON  399-800000-000

Detcon Solid State MOS Hydrogen Sulfiude (H2S) Sensor in Stainless Steel Housing for TP-524D



 
> HYDROGEN SULFIDE :    38 Items found.
M015-0002-000
(6332)

MPOWER  M015-0002-000

mPower UNI 321 Disposable Single Gas Detector for detection of Hydrogen Sulfide (H2S) 0.1-100ppm. Up to 36 months of live. Large LCD display will show time remaining or low/high alarm levels when hit, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$108.80 
BWC2-H
(4263)

BW  BWC2-H

BW Clip portable gas detector 2 year maintenance free for Hydrogen Sulfide (H2S). Low alarm set at 5 ppm or 10ppm, High alarm set to 10 ppm or 15 ppm. UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

M001-0054-000
(6001)

MPOWER  M001-0054-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen Sulfide (H2S) 0-100ppm to 0-1000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$134.40 
BWC2R-H
(5148)

BW  BWC2R-H

BW Clip Real Time portable gas detector with 2 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWC3-H510
(4268)

BW  BWC3-H510

BW Clip portable gas detector 3 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). UL approved for Class I Div 1. ATEX, CE, EC and IECEx approved.

TX1-2
(5966)

INDUSTRIAL SCIENTIFIC  TX1-2

Industrial Scientific Tango TX1 Gas Detector for Hydrogen Sulfide (H2S) 1-500 ppm. DualSense® Technology. 2-year run time. Includes LCD Display and 100dB audible alarm. Polycarbonate enclosure. IP66 & IP67. ATEX, CSA, IECEx, UL & INMETRO Approvals.

BWC3R-H
(5152)

BW  BWC3R-H

BW Clip Real Time portable gas detector with 3 year maintenance free for Hydrogen Sulfide (H2S). Configurables Low and high alarm (ppm). One-button operation. Designed for harsh environments and extreme temperatures. Includes a real-time gas level display. IP66 / IP67. UL approved for Class I Div 1. ATEX, CE, EAC Ex and IECEx approved.

BWS1-HL-Y
(6389)

BW  BWS1-HL-Y

BW Solo Serviceable Single-gas Detector for Hydrogen Sulfide (H2S) 0-200 ppm or 0-500 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PC3-6424
(6805)

PROSENSE  PC3-6424

Prosense PC3-6424 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with range 0-100 ppm. Epoxy painted aluminum housing and Nickel Plated Brass sensor head. 4-20mA Analog and Modbus RS485 RTU outputs. Optional Relay Outputs. IP65, Zone 2.

Configure

$514.80 
P-6434
(6775)

PROSENSE  P-6434

Prosense P-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$592.02 
TX-6-HS
(2045)

MACURCO  TX-6-HS

Macurco TX-6-HS low voltage Gas Detector, Controller and Transducer for Hydrogen Sulfide (H2S) 0-50 ppm. Selectable 4-20 mA output, buzzer, alarm and fan relays with digital display. 12 to 24 VAC or 12 to 32 VDC power. ETL Listed to UL 61010-1.

Configure

$648.99 
TX-12-HS
(3419)

MACURCO  TX-12-HS

MACURCO TX-12-HS line voltage Gas Detector, controller and transducer for Hydrogen Sulfide (H2S) 0-50 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

Configure

$656.26 
SPSTAXH1
(1474)

HONEYWELL  SPSTAXH1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen Sulfide (H2S) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-20 ppm, 0-50 ppm, 0-100 ppm)

Configure

$668.93 
364-455-01-365-756-11100
(6154)

DELPHIAN  364-455-01-365-756-11100

Delphian GazTell Fixed Point Electrochemical Gas Detector for Hydrogen Sulfide (H2S) 0-25, 0-50 or 0-100 ppm. 4-20mA Output. Optional Modbus RTU Output and Alarm Relays. SIL2 Approval. Suitable for Class I Div 1 & 2 Groups C, D.

PQN-6434-1/2
(6953)

PROSENSE  PQN-6434-1/2

Prosense PQN-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$772.20 
XT-00H0-Y-NA
(580)

BW  XT-00H0-Y-NA

GasAlertMax XT 4-Gas Detector for H2S ( Hydrogen Sulfide). Monitors up to 4 gas hazards for confined space entry and remote sampling.

OI-6000-EC-H2S-X-R_-DC-C
(6830)

OTIS  OI-6000-EC-H2S-X-R-DC-C

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Hydrogen Sulfide (H2S) 0-100ppm. Non explosion proof. Wired power (3-Wire) (12 to 35 VDC) with 4-20 mA analog, RS-485 Modbus and 2 relay outputs. 3 Push-Button Interface. IP 66/67. Optional radio. UL Approved.

PQD-6434-1/2
(6725)

PROSENSE  PQD-6434-1/2

Prosense PQD-6434 Gas Detector with Electrochemical sensor for Hydrogen Sulfide (H2S) with ranges 0-100ppm or 0-500ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$926.64 
OI-6000-EC-H2S-X-X-O
(6834)

OTIS  OI-6000-EC-H2S-X-X-O

Otis Instruments OI-6000 Gas Leak Detector with electrochemical sensor for Hydrogen Sulfide (H2S) 0-100ppm. Explosion Proof Wired power (3-Wire). (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs. 3 Push-Button Interface. IP 66/67. Optional alarm relays and Radio. CSA Approved for Class I Div 1. ATEX Zone 1 and IECEx Certified.

GG-H2S-50
(4136)

CALIBRATION TECHNOLOGIES  GG-H2S-50

CTI GasGuard H2S Hydrogen Sulfide Electrochemical Sensor (0-50 ppm) for gas leak detection in process areas, tank storage, sanitizing systems and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
Page: 1 | 2 | All
Cookie Notice