E2s E2xs1fdc024cn1a1b | Horns | Class I Div 2 And Class Ii Div 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   E2XS1FDC024CN1A1B

E2S E2XS1FDC024CN1A1B
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S E2xS1F 116dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.

E2XS1FDC024CN1A1B   
Please Email us your request for quote   

Voltage
Cable Entries
Bracket
Metric Adaptor

   2 Weeks  ]
48 Variants of base SKU / 30 Shown below

The hazardous area E2xS1F alarm horn sounder is UL/cULs approved for Class I Div 2 and Class II Div 2 as well as IECEx and ATEX certified for Zone 2 and 22 applications.

With a nominal sound level output of 116dB(A) at 1 metre and a choice of 45 alarm tones and 3 remotely selectable stages the E2xS1F alarm sounder horn is suitable for all general signalling duties.

The E2x range features enclosures manufactured from lightweight, corrosion proof PPS and high impact, fire retardant ABS re-entrant flare horns; both of which are suitable for the harshest of environments.

Features:
  • Automatic synchronisation on multi-sounder system.
  • Continuously rated.
  • Large termination area.
  • Stainless steel fixings.
  • Ratchet adjustable stainless steel ‘U’ bracket for 360° positioning.
  • Duplicate cable terminations (in & out for daisy-chain installations).
  • Tropicalisation available on request.
  • Available with custom tone configurations and frequencies.
Approvals:

  • ATEX certificate: DEMKO 06 ATEX 0421554X
  • IECEx certficate: IECEx ULD 14.0012X
  • UL/cUL File ref: E230764
Coding
  • IECEx / ATEX:
    II 3G Ex nA IIC T4 Gc Ta -20°C to +55°C
    II 3D Ex tc IIIC T85°C Dc Ta -20°C to +55°C
  • NEC Class / Zone ratings US:
    Class I Zone 2 AEx nA IIC T4 Gc Ta -20°C to +55°C
    Zone 22 AEx tc IIIC T85°C Dc Ta -20°C to +55°C
  • CEC Class / Zone ratings Canada
    Ex nA IIC T2 Gc Ta -20°C to +55°C
    Ex tc IIIC 85°C Dc Ta -20°C to +55°C
  • NEC & CEC Class / Division Ratings for US / Canada
    Class I, Div 2, ABCD T3C Ta -20°C to +55°C
    Class I, Div 2, ABCD T4 Ta -20°C to +40°C
    Class II, Div 2, FG T6 Ta -20°C to +55°C
    Class II, Div 2, FG T6 Ta -20°C to +55°C

Specification
Maximum output: 116dB(A) @ 1 metre [107dB(A) @ 10ft/3m]
Nominal output: 113dB(A) @ 1m +/- 3dB – Tone 2 [104dB(A) @10ft/3m]
No. of tones: 45 (UKOOA / PFEER compliant)
No. of stages: 3
Volume control: Max. 113dB(A); Min. 105dB(A) - Tone 2
Effective range: 100m/328ft @ 1KHz
Voltages DC: 24Vdc (10-30Vdc); 48Vdc
Voltages AC: 115Vac; 230Vac
Ingress protection: IP rating per EN60079-0:IP64
IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/13
Enclosure material: UL94V0 PPS & ABS
Lens material: Borosilicate glass dome with PC prismatic lens cover.
Guard: Stainless Steel dome guard as standard
Cable entries: Dual M20x1.5 or 1/2"NPT
Terminals: 0.5 to 1.5mm2 cables.
Line monitoring: Blocking diode included EOL can be factory fitted
Operating temp: -20 to +55°C [-4° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 2.5kg/5.5Ibs AC: 3.00kg/6.6Ibs
*SPL data +/-3dB(A). Measured at optimum voltage.
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)85318030

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    73 Items found.
BEDHEADR
(3644)

E2S  BEDHEADR

E2S BEDHEAD Alarm Sounder 90dB(A). Low current consumption. Suitable for close proximity signalling. 24VDC.

SONF1DC012_R
(3638)

E2S  SONF1DC012R

E2S SONF1 compact and high output Alarm Sounder 100dB(A). Low current consumption and high SPL. Stainless steel fixings. 12VDC, 24VDC, 24VAC, 115VAC or 230VAC Versions. IP66. VdS and GOST-R Approved. Optional UL & cULs version.

H100T030G
(3586)

E2S  H100T030G

E2S H100T signalling Horn with Trumpet 100dB(A). Compact with high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 12-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

H100B030G
(3587)

E2S  H100B030G

E2S H100B signalling Horn 100dB(A). Compact with high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 12-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

SON2DC012R
(3640)

E2S  SON2DC012R

E2S SON2 compact and high output Alarm Sounder 104dB(A). Low currentconsumption and high SPL. Stainless steel fixings. 24VDC, 24VAC, 115VAC or 230VAC Versions. IP66. GOST-R Approved.

A100SONTELR
(3270)

E2S  A100SONTELR

E2S A100SONTEL compact and high output telephone initiated Alarm Sounder 100dB(A). Three alarm tone frequency (siren, alternating, sweeping). Stainless steel fixings. High impact UL94 Housing. IP66. GOST-R Approved.

A100DC_24R
(3244)

E2S  A100DC24R

E2S A100 compact and high output Alarm Sounder/Horn 104dB(A). Low current consumption and high SPL. 115VAC, 230VAC, 24V, 10-30V or 48V Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

A105NSONTELR
(3272)

E2S  A105NSONTELR

E2S A105NSONTEL compact and high output telephone initiated Alarm Sounder 105dB(A). Three alarm tone frequency (siren, alternating, sweeping). Stainless steel fixings. High impact UL94 Housing. IP66. GOST-R Approved.

GPH2FEDC024G
(3646)

E2S  GPH2FEDC024G

E2S GPH2 Flush Mount Alarm Horn-Buzzer 105dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 24VDC, 115VAC or 230VAC Versions. IP54. UL and cULs Approved.

GPH1SEDC024G
(3645)

E2S  GPH1SEDC024G

E2S GPH1 Surface Mount Alarm Horn-Buzzer 105dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66. UL and cULs Approved.

B300SND030G
(3572)

E2S  B300SND030G

E2S B300SND Compact Signalling Horn 98dB(A). Buzzer type sound and two alarm sounds. Surface Mount. Stainless steel fixings. 12-30VAC/DC or 40-260VAC/DC Versions. IP65.

GPH3SEDC024G
(3647)

E2S  GPH3SEDC024G

E2S GPH3 Surface Mount Alarm Horn-Buzzer 110dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 10-30VDC/AC or 40-260VDC/AC Versions. IP66. UL and cULs Approved.

GPH4FEDC024G
(4441)

E2S  GPH4FEDC024G

E2S GPH4 Flush Mount Alarm Horn-Buzzer 110dB(A). Low current consumption and high SPL. Robust and fire retardant housing. Stainless Steel fixings. 10-30VDC/AC or 40-260VDC/AC Versions. IP66. UL and cULs Approved.

B400SND030G
(3580)

E2S  B400SND030G

E2S B400SND Compact Signalling Horn 110dB(A). Buzzer type sound and two alarm sounds. Surface Mount. Stainless steel fixings. 10-30VAC/DC or 40-260VAC/DC Versions. IP65.

H110T030G
(3593)

E2S  H110T030G

E2S H110T signalling Horn with Trumpet 110dB(A). With very high output signal to generate a traditional 'buzzer' warning or two further alarm sounds. Surface Mount. Volume control and Stainless Steel fixings. 10-30VAC/DC or 40-260VAC/DC Versions. IP65. GOST-R Approved.

A105NDC_24R
(3271)

E2S  A105NDC24R

E2S A105N high output Alarm Sounder 112dB(A). Low current consumption and high SPL. 24VAC, 115VAC, 230VAC, 24V, 48V or 100V Versions. Stainless steel fixings. Programmable version available. IP66. VdS, GOST-R and MED Approved. UL version available.

IS-MA1-R
(3689)

E2S  IS-MA1-R

E2S IS-mA1 IS-minialarm compact Alarm Sounder 100dB(A). 16-28VDC. Stainless Steel fixings. IP65. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class 1 Div 1 and Class 1 Zone 0.

A105NAXDC024R-UL
(3273)

E2S  A105NAXDC024R-UL

E2S A105NAX Appello X User Recordable Alarm Sounder 102dB(A). Low current consumption. 10-30VDC or 90-250VAC Versions. Robust fire retardant Type 4/4X/3R/13, IP66 housing. UL approved.

IS-A105N-G
(3687)

E2S  IS-A105N-G

E2S IS-A105N high output Alarm Sounder 105dB(A). 16-28VDC. Stainless Steel fixings. IP66. ATEX, IECEx and GOST-R approved for Zone 0. FM approved for Class 1 Div 1 and Class 1 Zone 0.

A112NDC_24R
(3274)

E2S  A112NDC24R

E2S A112N high output Alarm Sounder 119dB(A). High SPL. 24VAC, 115VAC, 230VAC, 24V, 48V or 100/230V Versions. Stainless steel fixings. Programmable version available. IP66. VdS, GOST-R and MED Approved. UL version available.

Page: 1 | 2 | 3 | 4 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.