MRU NOVA PLUS Portable Emissions Analyzer for measurement of up to 8 gases simultaneusly, includes long life (4-5 years) O2 [0-25%], CO (H2-compensated) sensor [0-4000ppm], calculated CO2 and gas cooler. Optional NDIR measurement CO2 and Hydrocarbons CxHy, electrochemical CO-Very High, NO, NO2, SO2 and H2S. Supports up to 5 electrochemical sensors. IP20. Includes Li-ion battery (up to 20 hours), 3.5" TFT backlit display, Built-in printer, Bluetooth, USB port, SD card reader, charger and transport case.

947010US   
6,299.00

Special CO Sensor
O2+CO+CO2(calculated) included in base unit
NO Sensor (calculated NOx)
O2+CO+CO2(calculated) included in base unit
Calculated NOx is NO + 5%
NO+NO2 Sensors (True NOx)
O2+CO+CO2(calculated) included in base unit
True NOx required for high NO2 applications such as gas turbines and compliance testing on compressor stations.
SO2/H2S Sensors
O2+CO+CO2(calculated) included in base unit
NDIR Sensor CO2/HC
Gas cooler
CO sensor protection
Flow Monitoring
Automatic zeroing
Active VENT port
Soot Measurement
Probe with Steel Tubes
Probe with Inconel/ceramic Tubes
MRU4win

 3 Days  ]

PORTABLE EMISSIONS ANALYZER for industrial combustion / emissions tuning, compliance reporting or trouble-shooting.

  • Simultaneous measurement of up to 8 gases
  • Automatic calculations and data logging
  • Easy operation via intuitive Remote Control Unit
  • Rugged design for extreme field conditions
  • Accuracy and reliability on numerous applications
BASE Unit:

Measuring 02, CO, COz, NO, NOz, SW, CO-high, & CO-very high
Stack temperatures up to 2000F
Draft pressure to ±40"

  • Emission calculations of mass flow, calculated or True NO(x), plus 02 referencing to user defined values
  • Combustion calculations of CO2, CO/CO2 ratio, Excess air, Air ratio, Dewpoint, Efficiency & Heat losses
  • Large condensate separator with PTFE coated filter
  • High energy Li-Ion battery provides up to 20 hours operation time
  • Built-in speed printer with easy paper loading for quick on-site documentation
  • Compact and rugged transport case
Options:
  • Gas conditioning via high efficiency Peltier gas cooler
  • CO protection with fresh air pump and cut off valve
  • Internal sample flow monitoring
  • Auto zeroing
Remote Control Units (RCU)
  • Bluetooth communication with base unit
  • Large color graphic, backlit display with zoom function
  • Simple, intuitive operation customizable screen settings
  • Durable and dirt resistant keypad
  • 16,000 measurement internal data storage
  • High energy Li-ion battery provides up to 30 hours operation time
  • Wireless battery charging via Base Unit cradle
  • USB interface
  • SD card reader for additional memory and easy data handling
  • Optional - Wireless PC interface via Bluetooth
Additional features of the COMFORT RCU
  • Integrated Manometer for differential pressure and flow
  • Differential Temperature inputs
  • Auxiliary (AUX) input for optional HC or humidity probe
Software Options:
  • MRU Online View Software for real-time monitoring and reporting
  • MRU 4 U Application for iOS and Android SMART devices

Measurement componentsMeasuring rangeAccuracy
O2 Oxygen0 ... 21.0 Vol%± 0.2 Vol% abs.
CO Carbon monoxide (H2 compensated)0 ... 4,000 ppm overload 10,000ppm *± 10 ppm or 5 % reading < 4,000 ppm / 10 % reading > 4,000 ppm
CO Carbon monoxide low0 ... 500 ppm with 0.1 ppm resolution **± 2.0 ppm or** 5 % reading
CO Carbon monoxide high0 ... 4,000 ppm overload 20,000ppm *± 20 ppm or 5 % reading < 4,000 ppm / 10 % reading > 4,000 ppm
CO Carbon monoxide very high0 ... 40,000 ppm overload 100,000ppm *± 0.02% or 5 % reading < 0.4% / 10 % reading > 0.4%
NO Nitric oxide0 ... 1,000 ppm overload 5,000ppm *± 5.0 ppm or 5 % reading < 1,000 ppm / 10 % reading > 1,000 ppm
NO Nitric oxide low0 ... 300 ppm with 0.1 ppm resolution **± 2.0 ppm or** 5 % reading
NO2 Nitrogen dioxide0 ... 200 ppm overload 1,000ppm *± 5 ppm or 5 % reading < 200 ppm / 10 % reading > 200 ppm
NO2 Nitrogen dioxide low0 ... 100 ppm with 0.1 ppm resolution **± 2.0 ppm or** 5 % reading
SO2 Sulfur dioxide0 ... 2,000 ppm overload 5,000ppm *± 10 ppm or 5 % reading < 2,000 ppm / 10 % reading > 2,000 ppm
CO2 Carbon dioxide single NDIR0.....40%± 0.3 % or 5% reading
CO Carbon monoxide 3 Gas NDIR0.....10,000ppm up to 10%± 0.03% or ±3% of reading
CO2 Carbon dioxide 3 Gas NDIR0.......3% up to 30%± 0.5% or ±3% of reading
CxHy Hydrocarbons as CH4 or 3 Gas NDIR0.....10,000ppm up to 3%± 0.03% or ±3% of reading
CxHy Hydrocarbons as C3H8 or 3 Gas NDIR0.....2,000ppm up to 5,000ppm± 30 ppm or ±3% of reading
*overload range recommend only for short time measurements
**are not separate sensors; selected sensors are used with special calibration
TECHNICAL SPECIFICATIONS
Stack / Flue gas temperature0 ... 1,200°F / 2,012°F (with stainless steel / Inconel steel tube) / ± 4°F ... < 392°FF / 1 % reading > 392°F
Primary-air / Ambient temperature0 ... 212°F ± 2°F
Differential temperatureup to 2,012°F (with suitable material of sampling tube) ± 4°F ... < 392°FF / 1 % reading > 392°F
Stack / Differential pressure+/- 40 inH2O (100hPa) ± 0.01 inH2O or 1% reading
Gas flow velocity measurement1 ... 40 m/s (using Pitot tube)
Operation temperature41°F .... 113°F, max. 95 % RH, none condensing
Storage temperature-4°F ..... 122°F
Ambient conditionsnot in aggressive, corrosive or high dust environments, not for use in hazardous areas
Power supplyBase Unit: Lithium-Ion battery, 20 h operation, (with gas cooler 10 h)
RCU: Lithium-Ion battery, 30 h operation
Grid power supply100 - 240 Vac / 50 ... 60 Hz / 5A
Protection classIP20
WeightComplete unit approx. 16.3lbs / RCU 0.88lbs
DimensionsComplete unit 18.5" x 9" x 12" (W x H x D) RCU 7.36" x 3.54" x 1.5"
Export Info
Made inGermany
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> MULTI-GAS :    5 Items found.
681000
(6609)

MRU  681000

MRU 400GD Multifunction Digital Detector for Gas Leakage and Stack Moisture Test with exchangable sensors. Accepts CH4, C3H8, H2, CO2, CO, RH, refrigerants and temperature sensors. Acoustic, optical and vibration alerts. Graphic color display and Lithium-ion battery. IP30.

Configure

$417.00 
420082
(6562)

MRU  420082

MRU AMPRO Plus Handheld Combustion & Emission Analyzer for measurement of up to 7 gases simultaneusly, includes long life (4-5 years) O2 [0-21%] and CO (H2-compensated) [0-4,000 ppm/overload 20,000 ppm] sensors, also included calculated CO2. Optional NDIR measured CO2, NDIR measured hydrocarbons, electrochemical NO, NO2, SO2, CO-High, CO-very high. Supports up to 5 electrochemical and 1 CO2+Hydrocarbon NDIR sensors. IP42. Includes Li-ion battery (up to 15 hours), 3.5" TFT backlit display, USB port, SD card reader, IRDA interface, condensate separator, charger, Bluetooth, Smartphone App. Replaces AMPRO 2000.

Configure

$2,367.00 
420074US
(6986)

MRU  420074US

MRU OPTIMAX BIOGAS, LANDFILL, COMBUSTION and WASTE WATER Hand Held Biogas Analyzer for measurement of Methane (CH4) 0-100%, Carbon Dioxide (CO2) 0-100%, Hydrogen Sulfide (H2S) 0-2000/5000ppm, Oxygen (O2) 0-25% and Biogas Pressure. Gas flow velocity, flow rate, differential temperature and differential pressure measurement. IP30. Includes 4” color display, Li-ion battery (up to 15 hours), internal data storage, bluetooth, Mini-USB interface, IRDA interface, WLAN interface, microSD card reader and charger. -Replaces Optima 7 Biogas-

Configure

$5,999.00 
947017US
(6576)

MRU  947017US

MRU NOVA PLUS BIO Portable Biogas and Combustion Analyzer for measurement of up to 8 gases simultaneusly, includes long life (4-5 years) O2 [0-25%], CH4 sensor [0-100%], CO2 sensor [0-60%], H2S sensor [0-2000ppm] and gas cooler. Optional Biogas pressure measurement [0-±300 mbar], electrochemical CO (H2 compensated), NO, NO2 and H2S. Supports up to 5 electrochemical sensors. IP20. Includes Li-ion battery (up to 20 hours), 3.5" TFT backlit display, Built-in printer, optional Bluetooth, USB port, SD card reader, charger and transport case.

Configure

$9,008.00 
951051
(6712)

MRU  951051

MRU SWG 100 CEM Stationary Continuous Emissions Analyzer for CEMS applications for measurement of Oxygen (O2) 0-25%, Carbon monoxide (CO)0-10000ppm, Carbon Dixide (CO2) 0-40%, Nitric oxide (NO) 0-4000ppm, Nitrogen Dioxide (NO) 0-1000ppm or Sulfur dioxide (SO2) 0-4000ppm with NDIR and electrochemical cells. 4x4-20 mA, 2 alarm relays and RS485 Modbus. IP54.

Configure

$14,566.00 
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.