Honeywell Spxcdulng1 | Hydrogen | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   SPXCDULNG1

HONEYWELL SPXCDULNG1
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell XCD Sensepoint Gas Detector, Hydrogen (H2) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for hydrogen (H2) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 1,000ppm only. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

SPXCDULNG1   
1,566.91

Modbus RTU
Enclosure
Agency Approval
Entry
Sunshade/Deluge Protection
Custom Tag

   5 Weeks  ]



XCD normal display (green) XCD Display in Fault/Warning (Yellow) XCD display in Alarm (Red)
Normal Fault/Warning Alarm
FEATURES

One-Stop Shop
  • Flammable (catalytic or infrared), toxic and oxygen versions available
  • New and retrofit applications
  • Suitable for indoor or outdoor use
  • Stainless steel or aluminium explosion-proof housing options
  • IP66 as standard
Proven and Reliable Sensor Technology
  • SurecellTM electrochemical sensors
  • Reflex® sensor health check
  • Poison immune infrared sensors
  • Poison resistant catalytic bead sensors
  • Long life sensors
Global Approvals
  • US and Latin America, European, Canadian and Asian
  • Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards
Easy to Use
  • User friendly and intuitive tri-colour backlit display with digits, bar graph and icons
  • Fully configurable via magnetic switches
  • Selectable sink or source 4-20mA output
  • Auto-inhibit during maintenance
  • MODBUS communications for remote diagnostics/configuration
Cost Effective
  • Common transmitter platform
  • Minimal training required
  • Reduced spares
  • Non-intrusive, one-man operation
  • Plug-in sensor replacement
  • MODBUS multi drop option offers cabling savings
Simple Installation
  • Plug-in display module removes to give access to terminal area
  • Integral mounting bracket
  • 2 x M20 or 3⁄4” NPT cable/conduit entries (certification dependent)
  • Removable plug/socket type terminal blocks for ease of wiring
  • Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
  • Remote sensor gassing kit
  • Duct mounting kit
  • Calibration gas flow housing
  • Collecting cone

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs

Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy to replace plug-in sensors, downtime is also reduced and on-going costs are minimized through the use of poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented SurecellTM toxic sensors and Reflex® sensor health check.

All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and Modbus.

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either conduit or cable with suitable mechanical protection. Two M20 or 3⁄4”NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit and collecting cone.

TYPICAL APPLICATIONS

  • Industrial manufacturing facilities
  • Power plants
  • Waste water facilities
  • Utilities
  • Food and beverage production
  • Refineries and chemical plants
  • Onshore oil and gas terminals
  • Production platforms
  • Exploration and drilling
Honeywell XCD detector components

1 Cover
2 Display module
3Terminal area
4 Blanking plug
5 Transmitter
6 Plug-in XCD sensor
7 Sensor retaining ring
8 Integral mounting plate
9 Weather protection assembly
10 Cable/conduit entry (x2)
11 Certification label

There are three different types of the XCD transmitter for use with three different families of sensors.

The mV type transmitter is for use with the mV family of XCD sensors including catalytic sensors to detect flammable gases in the range 0-100%LEL and infrared (IR) sensors for detection of Hydrocarbon gases in the range 0-100%LEL, as well as Carbon Dioxide (CO2) in the range 0-2%Vol.

The EC type transmitter is for use with the EC family of XCD sensors including Carbon Monoxide (CO), Hydrogen Sulfide, (H2S), Hydrogen (H2) and Nitrogen Dioxide (NO2).

The Oxygen transmitter is for use with the Oxygen (O2) XCD sensors.

A transmitter can auto-recognize any sensor from within its sensor family. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly.

Sensepoint XCD uses three instantly recognizable ‘traffic light’ colors to indicate its status. The large tri-color backlit LCD is steady green to indicate normal operation, flashes yellow to indicate a fault/warning and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.

Specifications
Gas Hydrogen
Sensor Family EC
User Selectable Full Scale Range 1,000ppm only
Default Range 1,000ppm
Steps n/a
User Selectable Cal Gas Range 30 to 70% of selected full scale range
Default Cal Point 500ppm
Response Time (T90) Secs <65
Accuracy <+/-25ppm
Min Operating Temperature -20°C / -4°F
Max Operating Temperature 55°C / 131°F
Default Alarm Point A1 200ppm ▲
Default Alarm Point A2 400ppm ▲

General Transmitter Specifications
Use 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and Oxygen hazards. Incorporating a transmitter with local display and fully configurable via non-intrusive magnetic switch interface.
Electrical
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Maximum power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W, IR = 3.7W and catalytic = 4.9W. Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable)
Alarm relays default normally open/de-energized. Fault relay default normally open/energized
Communication RS485, MODBUS RTU
Construction
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: 316 stainless steel
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Cable Entries UL\cUL versions: 2 x ¾"NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating; ATEX/IECEx versions: 2 x M20 cable entries
Environmental
IP Rating IP66 in accordance with EN60529:1992

Certification
US, Latin America, Canada UL/c-UL - Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40°C to +65°C
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
International IEC Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
EMC CE: EN50270:2006 EN6100-6-4:2007
Performance UL508; CSA 22.2 No. 152 (flammable gasses, excludes infrared sensors); ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271; China: PA Pattern Measurement (for transmitter and toxic gas sensors) “CCCF” Shenyang for Flammable (fire dept approval)

Honeywell Sensepoint XCD Part Number

Honeywell Sensepoint XCD Option Matrix

Export Info
Made inSouth Korea
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    9 Items found.
SPXCDMTBR
(670)

HONEYWELL  SPXCDMTBR

Mounting bracket for Honeywell Sensepoint XCD Sensors. Includes bolts, nuts and brackets



$104.72 
S3KCAL
(667)

HONEYWELL  S3KCAL

Calibration Cap/Cup for Honeywell Sensepoint XCD Sensors.



$117.16 
(668)

HONEYWELL  SPXCDCC

Collecting cone for use with lighter than air gases for Honeywell Sensepoint XCD Sensors.



$119.23 
CYL-90090146
(4055)

PORTAGAS  CYL-90090146

Calibration Gas Hydrogen (H2), 500 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90090145
(1551)

PORTAGAS  CYL-90090145

Calibration Gas Hydrogen (H2), 1000 ppm Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
SPXCDSDP
(671)

HONEYWELL  SPXCDSDP

Sunshade/Deluge Protection for Honeywell Sensepoint XCD Sensors.



$402.28 
SPXCDDMK
(669)

HONEYWELL  SPXCDDMK

Duct mounting kit for Honeywell Sensepoint XCD Sensors.



$443.75 
SPXCDXSG1SS
(681)

HONEYWELL  SPXCDXSG1SS

Replacement Sensor Cartridge for Hydrogen (H2) XCD Detector 0-1000ppm



$867.80 
TPPLBDWA2NNNNNN
(5825)

HONEYWELL  TPPLBDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8mA outputs. IP65. UL and CSA approvals (Class I Div 2).

> HYDROGEN :    23 Items found.
M001-0019-000
(6329)

MPOWER  M001-0019-000

mPower UNI MP100 Portable Single Gas Detector for detection of Hydrogen (H2) 0-1000ppm or 0-2000ppm. Includes large LCD display, 6 Bright Red Flashing LED, Vibrating and 90dB Audible Alarm Port. IP67, Event Logger, ATEX and UL approval for Class I Div 1.

Configure

$278.40 
P-3634
(6776)

PROSENSE  P-3634

Prosense P-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm to 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx approval (Zone 1 or Zone 2). IP65, Optional IP66 Adaptor.

Configure

$540.54 
PQN-3634-1/2
(6948)

PROSENSE  PQN-3634-1/2

Prosense PQN-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor and remote display.

Configure

$720.72 
BWS1-R-Y
(6387)

BW  BWS1-R-Y

BW Solo Serviceable Single-gas Detector for Hydrogen (H2) 0-1000 ppm. Small and lightweight. One button operation, 3.6V 1.65Ah Lithium Battery. Visual, vibrating and audible alarms. Optional wireless version. IP66/68. ATEX, IECEx and CSA approvals for Class I Div 1.

PQD-3634-1/2
(6737)

PROSENSE  PQD-3634-1/2

Prosense PQD-3634 Gas Detector with Electrochemical sensor for Hydrogen (H2) with ranges 0-500ppm, 0-1000ppm or 0-2000ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2), UL/CSA (Class I Div 1), UKCA or INMETRO approval, optional SIL2. IP65, Optional IP66 Adaptor.

Configure

$875.16 
SPSTAXG1
(1487)

HONEYWELL  SPSTAXG1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Hydrogen (H2) with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-1000 ppm, 0-10000 ppm)

Configure

$929.07 
GG-H2-EC-2000
(2965)

CALIBRATION TECHNOLOGIES  GG-H2-EC-2000

CTI GasGuard H2 Hydrogen Catalytic Bead Sensor 0-1% (10000 ppm or 25%LEL) for gas leak detection in battery charging rooms, steel industry, refineries and others. No false alarms. 4-20 mA output, 24VDC power supply and NEMA 4X polycarbonate enclosure.

Configure

$1,122.00 
2106B1416
(1462)

HONEYWELL  2106B1416

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen (H2) (0-1000 ppm to 0-10000 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
GG-H2-EC-10000-EXP
(5978)

CALIBRATION TECHNOLOGIES  GG-H2-EC-10000-EXP

CTI GG-H2-EC-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen (H2) 0-2000 ppm and 0-10000 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,383.00 
100-0008-SS/100-0015-H2
(4753)

ESP SAFETY  100-0008-SS/100-0015-H2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Hydrogen (H2) 0-4% vol or 0-100ppm (Catalytic bead or electrochemical). Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
961-070026-01PG
(6053)

DETCON  961-070026-01PG

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-1%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

961-840026-100G
(6363)

DETCON  961-840026-100G

Detcon DM-102-H2 Electrochemical Hydrogen (H2) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

S3KUL2-XNXXSG1SS
(689)

HONEYWELL  S3KUL2-XNXXSG1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN (H2) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-1,000ppm ,0-10,000ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,806.92 
SPXCDULNG2
(5102)

HONEYWELL  SPXCDULNG2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen (H2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 1000 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
2100AL-0-1018/0500P/L0
(120)

RC SYSTEMS  2100AL-0-1018/0500P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$2,003.89 
41001AL-0-1019/0500P/L0
(7163)

RC SYSTEMS  41001AL-0-1019/0500P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$2,025.97 
51001AL-0-1019/0500P/L0
(7126)

RC SYSTEMS  51001AL-0-1019/0500P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$2,081.82 
31001AL-0-9018/2000P/L0
(5782)

RC SYSTEMS  31001AL-0-9018/2000P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen (H2) 0-500 to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$2,181.82 
XNXUTAENNNNN-XNXXSG1SS
(839)

HONEYWELL  XNXUTAENNNNN-XNXXSG1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen (H2) compatible with all Honeywell gas sensing technologieswith aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-1000ppm, 0-10000ppm

Configure

$2,221.73 
967-070790-01P
(6088)

DETCON  967-070790-01P

Detcon DM-702-H2 Electrochemical Smart Hydrogen (H2) 0-1% vol. Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.