PRODUCTS & SERVICES
Legal Exposure Limits
[ NIOSH Exposure Limits ]


Federal Government Contractor
(SAM) CAGE Code: 4W5M0

Why GasDetectors.com ?

  • GasDetectorsUSA.com provides a wide range of industrial gas detection systems including toxic, oxygen and combustibles, truly "state of the art" devices offering unparalleled features and capabilities along with Hazardous Area, Explosion Proof, UL, Atex and CSA certifications at a reasonable price. We also offer gas detection solutions with PLC & SCADA.

  • Our Broad spectrum of skills, experience and hands-on approach ensures the success of Your project
  • We provide specialized products, services or turnkey projects, to suit your needs in
    • Fixed gas detectors.
    • Portable gas detectors.
    • Multi-Point gas controllers.
    • Calibration Gases.
    • Alarm Signal Devices.
    • Installation and commissioning.
    • PLC-based gas detection solutions.
    • Data acquisition and SCADA.


Houston, TX USA

SKU#(837) Be the First to Review this Item

HONEYWELL  XNXUTAENNNNN-XNXXSL1SS

DETECTORS / GAS DETECTORS
CHLORINE

$1,519.75     Availability: 4 Weeks
 Information Request
 Shipping Rates
 Volume discount
      



HONEYWELL XNXUTAENNNNN-XNXXSL1SS
  • Overview
  • Benefits
  • Specs
  • Supplies
  • Related
  • Documents

Honeywell XNX Universal Gas Detector Transmitter for monitoring of Chlorine (Cl2) 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm) compatible with all Honeywell gas sensing technologies, with aluminum alloy LM25 housing. 3-wire 4-20mA HART loop, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1

Part # XNXUTAENNNNN-XNXXSL1SS

Part# with Options:        XNXUTAENNNNN-XNXXSL1SS
Price with Options:        1,519.75

Options:    

Agency Approval & Port Threads
(1) Honeywell XNX Transmitters
Enclosure
(2) Honeywell XNX Transmitters
Interface option
(3) Honeywell XNX Transmitters Output Option
Local HART Port
(4) Honeywell XNX Transmitters
Custom Tag
(5) SSTAG Stainless Steel Custom Tag for Honeywell Gas Detectors

  Availability 4 Weeks  ]

The XNX Universal Transmitter marks a new turn in gas detection from Honeywell Analytics. It supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs.

FEATURES

High performance
  • Flammable gas detection 0 to 100% LFL/LEL
  • Point IR with heated optics provides immunity to poisoning and no hidden faults
  • Open-path IR flammable gas detection in LEL-m measurement
  • Electrochemical cell offers toxic gas detection in ppm
  • IR cell provides CO2 and combustible gas monitoring
  • Robust and reliable operation in explosive areas and harsh environments
Flexible Operation
  • 3 versions - supports mV (Catalytic Bead and IR Cell), Electrochemical Cell and IR (point and open-path) gas detection
  • Multi-Purpose Detector (MPD) with field serviceable mV, Catalytic bead and IR Cell capability
  • 4-20mA with HART® as standard
  • Multiple communications options include up to 3 relays, MODBUS® and FOUNDATION® H1 Fieldbus (pending)
  • Optional local IS port for handheld HART configurator
Easy to Use
  • Large, backlit, easy-to-view LCD display offers multisensory indicators (visual icons, colored buttons, text, etc.) to display gas and sensor readings
  • User interface supported by 8 selectable languages (English, Spanish, German, Italian, Portuguese, French, Russian, Chinese)
  • Self-test and fault indication features
  • Non-intrusive, one-man operation
  • Quick calibration with auto-inhibit
Easy to Install
  • 3 or 4 wire operation, source, sink or isolated
  • Use with conduit or cable installations
  • Simple plug-in sensors and replaceable cells
  • NEMA 4X IP66 rated for rugged indoor/outdoor use
Cost Effective
  • Minimal training required
  • One-man operation
  • Plug-in sensor replacement
  • All necessary accessories included
Applications
  • Offshore Oil & Gas production platforms
  • Onshore Oil terminals
  • Refineries
  • Gas Transmission
  • Gas Distribution
  • LNG terminals
  • Gas storage terminals
  • Chemical plants
  • Petrochemical plants
  • Solvent recovery operations

XNX is designed for flexible integration, simple installation, user friendly operation and straightforward maintenance. It is ideal for use with a range of gas monitoring controllers or industry standard PLCs. Users are assured of being protected in all conditions with Honeywell Analytics gas monitoring solutions.

Bringing together the best solutions in gas detection

Electrochemical
  • Proven electrochemical sensing technology
  • Surecell™ electrochemical cells are ideal for hot and humid environments
  • Long life sensing cells (typical >2 years)
  • Patented 'Reflex' sensing element verification diagnostics
  • Sensor recognition software auto configures transmitter
  • Plug and play factory configured sensors
  • Intrinsically safe sensor connection permits hot swap, reducing down time
XNX Surecell Electrochemical sensors

XNX's modular design enables Honeywell Analytics to offer appropriate, cost effective solutions to a wide range of gas detection requirements.

With the XNX, you are freed from the need to add extra controllers, junction boxes, relays, monitors and other equipment accessories.

The XNX Universal Transmitter is an excellent choice for those who want a total integrated monitoring and safety solution for an industrial plant.

The XNX's powerful advanced communications module adds increased functionality and flexibility to a gas detection network. Standard HART communications, along with optional Modbus, Foundation Fieldbus (pending) or relays, interface with a PLC and a host of other protocol compatible devices found in industrial applications.

XNX Output Options

Back-lit, easy-to-read LCD display with icons includes a broad range of language options including English, Spanish, French, Italian, Portuguese, German, Russian and Chinese to meet global requirements.

Ordering Information

The XNX part numbering system contains all necessary information to convey the product configuration including options. Agency, Port Thread, Enclosure Material, Sensor Personality define the standard unit. Three option fields are used to define optional Relay or Fieldbus interfaces and factory installed local HART®. To order XNX parts, call 800-538-0363.

XNX Order Information Matrix

XNX Transmitter
Material LM25 Aluminum, painted (SS316 painted optional)
Cable Entries 5 conduits/cable entries – (2 right, 2 left, 1 bottom) Available in ¾" NPT, or M25
Termination Cage Clamp pluggable Terminal Blocks with retaining screws, 0.5 to 2.5mm (12-28 AWG)
Mounting XNX Enclosure Bracket (ears on casting for u-bolt). Integral cast mounting flanges provide secure mounting to surfaces, channels or up to 6" Pipe.
Optional Remote sensor (up to 50 ft / 15.2 M) for Cat Bead and Toxic
User interface Standard Custom Backlit LCD. 2.5" High Resolution DOT Matrix Display. Discrete Alarm and Status indication. Reliable Non-Intrusive 4 button interface magnetic wand access. Optional HART Handheld with IS Port
Signal Standard HART over 3-wire 4-20mA (sink or source). Optional Modbus over RS-485 and Foundation Fieldbus
Environmental
Temperature -40°C to +65°C / -40°F to +149°F (sensor dependent)
Humidity 20 to 90% RH non-condensing
IP Rating NEMA 4X IP65
Options
  Form C and SPDT 3 Relays, 240 VAC, 5A (2 Alarm, 1 Fault) (Mutually exclusive with Modbus and Fieldbus Options)
Power
  18V to 32V (24V nominal)
Hazardous Area Approvals
 
Performance Approvals UL Certified Class 1, Div 1
ATEX Zone 1
Display Module & User Interface (Standard)
Display Type Backlit LCD
Information Displayed
Base Information: Gas Reading
Gas Name and Units of measurement
Fault and Alarm Status
Large Numeric concentration or LEL display
Bar graph showing current reading, set points and full scale.
Fault/Alarm and Operating Status Indication: Security settings allow multi level operator access for set-up, configuration and calibration
Event history stores Time and Date of all Alarm, Diagnostic, Configuration events
Interface Magnetic wand with terminal screwdriver (supplied each unit)
4-20mA & HART (Standard Supply)
Description Fully configurable isolated 4-20mA & HART output module providing current sink, current source and isolated modes of operation. (supports HART 6.0 protocol)
Non-intrusive Interface Optional local IS port to enable HOT connection of a HART handheld configurator
Operating Modes Current sink / Current source / Isolated current sink /Conventional or with HART data
Output Range 0 to 22mA
4-20mA Signal Accuracy +/- 1% FS
Max loop resistance 600 Ohms at 24Vdc loop supply
Functions Supported via HART
Gas Reading Detailed Sensor Information Including: RTC (Excel Only)
Gas Name and Units of measurement 4-20mA signal level Optical Signal Level Calibration and Configuration status
General/Device Information Dynamic Reserve (Excel Only) Detailed Fault and Warning Information
Installation Raw reading Fault and Alarm History
Configuration Temperature
Forcing of 4-20mA output
Local IS HART Port (Optional)
Description Provides externally accessible IS connections to the XNX transmitter to enable HOT connection of HC275/375 HART or equivalent hand held configurator.
Installation Fitted to one of the cable entries on the XNX transmitter.
Environmental Protection Terminals protected by cover to IP 66 when not in use
Relay Module (Optional)
Description Provides three fully user configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO alarm and 1 x SPCO fault relays. Single Pole Double Throw SPDT. Option PCB Factory installed in display module.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Rating
Maximum: 240VAC, 5A (non inductive load) Minimum: 5V, 10mA (non inductive load)
Electrical Connections Fault: Common, Normally Open, Normally Closed
Alarm 1: Common, Normally Open, Normally Closed
Alarm 2: Common, Normally Open, Normally Closed
Configuration
Default Configurable Options
Fault Relay: Fault Relay:
Normally energized Normally energized / normally de-energized
Non latching None
Signal inhibit as fault Enable/disable
Alarm 1 / 2 Relays: A1 / A2 Relays:
Normally de-energized Normally energized / de-energized
Non latching Latching / non latching
Alarm rising on gas reading Alarm on rising / falling
Alarm level 20% and 40% of scale Alarm level 10% to 90% of full scale
Hysteresis of 2% of scale
Re-setting of Latched Relays Easily accessible interface on display (if used) or via HART interface (local or remote)
Note Use of the Relay Module or 'Other' Communications Module (E.g. Foundation Fieldbus) is mutually exclusive. However, relay function may be used in conjunction with standard communication output i.e. 4-20mA with HART.
Relay Specific Functions via HART Interface Relay status information / Reset of latched conditions / Configuration of relays Forcing of relay state
Reset through non intrusive User Interface. Remote Switch closure using Remote Reset input Remotely through HART
Foundation Fieldbus Module (Optional)
Description Foundation Fieldbus compliant digital communications interface enables connection of the XNX transmitter to a multi-drop Foundation Fieldbus H1 network.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Connections Sig+, Sig- and Screen
Physical Layer Conforms to IEC 1158-2 and ISA 50.02, 31.25Kbits/s
Maximum No. of Nodes 32
Functions Supported
Gas Reading Detailed Sensor Information Including: Detailed Fault and Warning Information:
Gas Name and Units of measurement Optical Signal Level Fault and Alarm History
Instrument status (OK, warning, fault, over-range) Dynamic Reserve (Excel Only) Zero Calibration
Remote zero and span calibration (detector dependent) 24V supply voltage
Remote zero and span calibration (detector dependent) Temperature
  RTC (Excel Only)
  Calibration and Configuration status
Modbus RTU Module (Optional)
Description The Modbus output module provides an Isolated RS485 output to enable the connection of the XNX transmitter to a multi-drop Modbus network
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Connections RS485+, RS485-, Drain
Physical Layer Isolated RS485, 1200 to 19.2K Baud
Maximum No. of Nodes 254 XNX compatible transmitters only
Protocol Modbus RTU
Functions Supported As per Foundation Fieldbus Module (Optional) - see above


  • SENSORS (REPLACEMENT) > HONEYWELL XNX
    XNXXSL1SS Replacement Sensor Assembly for Chlorine (Cl2) XNX Transmitter. 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm) ..

  • MULTI-POINT CONTROLLERS > 2-CHANNEL
    HA20PY Honeywell HA20 Digital Gas Detection ALARM CONTROLLER, with 2 channels and LCD display of 128x64 pixels. Has configurable control, flexible application and an user-friendly operation. UL/CSA approved, Class I, Division 2 - NEMA 4X, painted steel or stainl..


  • MULTI-POINT CONTROLLERS > 4-CHANNEL
    HA40PY Honeywell HA40 Digital Gas Detection ALARM CONTROLLER, with 4 channels and LCD display of 128x64 pixels. Has configurable control, flexible application and an user-friendly operation. UL/CSA approved, Class I, Division 2 - NEMA 4X, painted steel or stainl..



B2B Checkout Options: PO#, Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GAS DETECTORS > CHLORINE :    12 Items found.
SPSTAXL1 (1482) HONEYWELL  SPSTAXL1

Honeywell Zareba Sensepoint Gas Detector Transmitter for Chlorine (Cl2) 0-5ppm complete with pre-wired universal junction box (1 threaded M20, 1 clearance 3/4"NPT, 1 clearance 1/2" NPT, 3 approved stopping plugs, earth continuity plate) and factory set toxic gas sensor. 2 wire 4-20mA loop output. ATEX Approved. (Optional ranges: 0-5 ppm, 0-15 ppm)

  

$540.09        

 
2106B1410 (1456) HONEYWELL  2106B1410

Honeywell Sieger Sensepoint Gas Detector Transmitter for Chlorine (Cl2) (0-5 ppm to 0-15 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx Certified.

  

$764.45        

 
GDS-49-3-12-02 (160) GDS  GDS-49-3-12-02

GDS GDS-49 Remote Gas Detector Transmitter with stainless steel sensor head (non-XP) configured for Chlorine (CL2) with range 0-5 to 0-50 ppm. 2-Wire 4-20 mA transmitter.

  

$885.00        

 
TM-EC-48-12-02-0 (3387) GDS  TM-EC-48-12-02-0

GDS TRANSMAX EC Loop-Powered Gas Monitor with stainless steel sensor head and integrated sensor configured for Chlorine (Cl2) for range 0-5 to 0-50 ppm. 2-wire 4-20mA current sink output and large LCD Display. Polycarbonate housing (IP66/IP67).

  

$1,150.00        

 
SPXCDULNL2 (1898) HONEYWELL  SPXCDULNL2

Honeywell Sensepoint XCD RTD Gas Detector for Chlorine (Cl2) with Remote Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 5 ppm. UL/cCSAus Approved for Class I Div 2.

  

$1,130.36        

 
TMII-48-12-02/00-00-00/0-0 (149) GDS  TMII-48-12-02/00-00-00/0-0

GDS TRANSMAX II Gas Detector with Local DELDRIN sensor head (non-XP) with integrated sensor configured for Chlorine (Cl2) for range 0-5 to 0-50 ppm with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU, 4-20mA output transmitter.

  

$1,275.00        

 
S3KUL2-XNXXSL1SS (687) HONEYWELL  S3KUL2-XNXXSL1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum alloy LM25 housing for monitoring of CHLORINE (CI2) gas hazards in potentially explosive atmospheres, both in and out of doors using electrochemical sensing technology. Operates on an industry standard 2-wire 4-20mA loop, 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)

  

$1,219.26        

 
GM/EC-03-12-02 (118) GDS  GM/EC-03-12-02

GDS GASMAX/EC 2-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine (Cl2) with range 0-5 to 0-50 ppm, 4-20 mA output transmitter.

  

$1,435.00        

 
GMII-03-012-02/00-000-00/0-0 (136) GDS  GMII-03-012-02/00-000-00/0-0

GDS GASMAX II 3-Wire Gas Detector with local stainless steel sensor head (non-XP) configured for Chlorine (Cl2) with range 0-5 to 0-50 ppm, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU.

  

$1,605.00        

 
5100-06-IT-A1-01-0-0 (3074) SIERRA MONITOR  5100-06-IT-A1-01-0-0

Sierra Monitor 5200-06-IT Toxic Gas Leak Detector for Chlorine (Cl) 0-10ppm Electrochemical Sensor. ModBus RTU-485, 4-20mA output, HART interface and optional alarm relays, Explosion proof NEMA-4X Aluminium Enclosure. IP66. IP65. FM, SIL-2 and ATEX approved. Class I, Div. 1, Groups B, C, D.

  

$1,616.00        

 
100-0008-A1/100-0015-Cl2 (4750) ESP SAFETY  100-0008-A1/100-0015-Cl2

ESP Safety Vector 2-channel gas detector controller with smart Plug-In Sensor to Detect Chlorine (Cl2) 0-10ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. Explosion-proof housing. IP67. SIL certification.

  

$1,920.00        

 
C2-22-012-02/00-000-00/0-0-0-0-0/0-0 (366) GDS  C2-22-012-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Chlorine (Cl2) sensor with range 0-5 to 0-50 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.

  

$2,690.00        

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
XNXUTAENNNNN-XNXXS

Industrial Automation Services
Industrial Automation Services with PLC and SCADA


Previous Button
Next Button

 


| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view |   LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to GasDetectorsUSA.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site
|