Macurco Tx-12-am | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

MACURCO   TX-12-AM

MACURCO TX-12-AM
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
MACURCO TX-12-AM line voltage Gas Detector, controller and transducer for Ammonia (NH3) 0-100 ppm. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1.

TX-12-AM   
690.96

Voltage
Housing Color

   2 Days  ]
2 Variants of base SKU

The Macurco 12-Series are line voltage (100-240VAC), dual relay gas detector, controller and transducers. The 12-Series utilizes an internal switching power supply that is capable of using line voltage between 100 and 240VAC and 50-60Hz. The 12-Series have selectable 4-20mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of various gases and provide feedback and automatic control to help reduce gas concentrations in parking garages, maintenance facilities or other commercial applications.

Selectable options include:
  • Selectable relay actuation levels
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Buzzer, digital display, latching relay, relay delay, relay minimum runtime
Features:
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Supervised system design: detector problem will cause relay activation
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
12-Series Rear View

Specifications:
Power: 100-240VAC (50 TO 60 HZ)
Current: 1.0 A MAX
Shipping Weight: 1 pound (0.45 kg)
Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
Color: Dark gray
Connections: plugs/terminals
Mounting box: (not included) 4x4 electri
Fan relay: 5A, 240 VAC, pilot duty, SPDT, latching or non-latching
Fan relay actuation: Selectable within sensor range
Fan Delay Settings 0, 1, 3 (default), 5 and 10 minutes
Fan Minimum Runtime settings OFF (default), 3, 5, 10 or 15 minutes
Alarm relay: 0.5A 120 V, 60 VA
Alarm relay actuation: selectable N.O. default or N.C.
Alarm relay settings: Selectable within sensor range
Current Loop 4-20 mA
Operating Environment: 0°F to 125° F (-18°C to 52°C).10 to 90% RH
Buzzer Output: 85 dBA at 10cm settable to off (default) or on
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)8531100025

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    7 Items found.
CX/TX-CH
(2117)

MACURCO  CX/TX-CH

MACURCO Calibration Hood/cup for CX, TX, OX, & RD series gas detectors: ammonia (NH3), hydrogen sulfide (H2S) and Nitrogen Dioxide (NO2).



$33.38 
HS-B
(5735)

MACURCO  HS-B

Macurco HS Horn and Strobe for Macurco DVP-120 & DVP-120M control panels and Macurco 6 & 12 Series detectors. High power cool white LED. 15, 30, 75 or 110cd strobe candela. Continuous or Temporal 4 audio tones. 24VDC.

Configure

$177.87 
WHK-1
(3518)

MACURCO  WHK-1

Macurco WHK-1 weatherproof enclosure to protect all Macurco Series 6/12 standard 4x4 mount gas detectors Compatible with CM-6, GD-2A, GD-6, TX-6, OX-6, CX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors. NEMA-1



$183.15 
DMK-1
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
70-2900-0605-3
(2526)

MACURCO  70-2900-0605-3

MACURCO TX-6-AM (TX-12-AM) Ammonia NH3 Replacement sensor. (Replaces 26-2900-0005-4)

Configure

$347.25 
Cal-Kit 5*AM GAS 25PPM
(2996)

MACURCO  Cal-Kit 5*AM GAS 25PPM

Macurco Cal-Kit 5 Ammonia (NH3) 25 ppm gas field calibration kit to calibrate Macurco TX-6 fixed gas detectors. 34L. Includes Carry Case, Regulator, Tubing and calibration hood. 1/cs.



$879.27 
DVP-120
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
> AMMONIA :    42 Items found.
ECFX-200-N
(6467)

HONEYWELL  ECFX-200-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-200 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,596.46 
LBW-420-1-SS
(912)

COOL AIR  LBW-420-1-SS

Cool Air LBW-420 Ammonia (NH3) 0-100/1000ppm Gas Leak Detector 4-20mA analog output. NEMA 4X enclosure. Alarm, pre-alarm and auxiliary relays. 115/230 VAC, 50/60 Hz, or 24 VDC. User Adjustable ranges: 0-100, 0-250, 0-500 and 0-1000ppm

Configure

$1,631.80 
ECFX-1000-N
(6587)

HONEYWELL  ECFX-1000-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-1000 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,654.94 
LBW-420-LEL-DC-01
(6055)

COOL AIR  LBW-420-LEL-DC-01

Cool Air LBW-420-LEL Ammonia (NH3) 0-9.9% Gas Leak Detector. Includes 4-20mA analog output, 3 latching relays and LED Display. 18-36 VDC (Optional AC). NEMA 4X and UL listed enclosure.

Configure

$1,676.90 
ECFX-500-N
(6468)

HONEYWELL  ECFX-500-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-500 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

GG-NH3-2-EXP
(4149)

CALIBRATION TECHNOLOGIES  GG-NH3-2-EXP

CTI GasGuard NH3-2%-EXP Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressorrooms where E-stop or electrical shunt trip is desired. Explosion-proof. Enclosure and sensor head certified for hazardous locations. Industry standard linear 4-20 mA output. Power: 24 VDC, 120 mA. NEC, UL, CSA, FM and IEC Approvals.

Configure

$1,786.74 
2100AL-0-9012/0300P/L0
(132)

RC SYSTEMS  2100AL-0-9012/0300P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,789.61 
LBW-HHS-II
(1556)

COOL AIR  LBW-HHS-II

Cool Air LBW-HHS-II Portable Handheld Ammonia (NH3) Leak Detector. Glass Filled Polycarbonate Housing. Includes touch-sensitive LCD display, 3 concentration alarms (caution, warning and danger), USB output, RS-232 Output Cable, 4GB of internal memory and rechargeable NiMH battery.

Configure

$1,820.40 
VL-F7-NH3-N4-LPA-NO
(3720)

HONEYWELL  VL-F7-NH3-N4-LPA-NO

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). Continuos monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2” cast steel “T”. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp.



 
S3KUL2-XNXXSA1SS
(685)

HONEYWELL  S3KUL2-XNXXSA1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring AMMONIA (NH3) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-200ppm, 0-1000ppm. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,837.05 
961-500026-100G
(6349)

DETCON  961-500026-100G

Detcon DM-102-NH3 Electrochemical Ammonia (NH3) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ECFX-100-N
(1516)

HONEYWELL  ECFX-100-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-100 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
ECFX-250-N
(6588)

HONEYWELL  ECFX-250-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-250 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
SPXCDULNA2
(1897)

HONEYWELL  SPXCDULNA2

Honeywell Sensepoint XCD RTD Gas Detector for Ammonia (NH3) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
31001AL-0-9012/0300P/L0
(6888)

RC SYSTEMS  31001AL-0-9012/0300P/L0

RC Systems SenSmart 3100 3 wire gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,967.53 
967-505090-100
(6070)

DETCON  967-505090-100

Detcon DM-702-NH3 Electrochemical Smart Ammonia (NH3) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

VL-F7-NH3-N4-LPA-MK
(3716)

HONEYWELL  VL-F7-NH3-N4-LPA-MK

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). continuous monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2" cast steel T. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp. Includes mounting kit



 
XNXUTAENNNNN-XNXXSA1SS
(835)

HONEYWELL  XNXUTAENNNNN-XNXXSA1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Ammonia (NH3) compatible with all Honeywell gas sensing technologies, with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-200ppm, 0-1000ppm

Configure

$2,251.86 
IR-F9-NH3-0/2-N1
(1548)

HONEYWELL  IR-F9-NH3-0/2-N1

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Ammonia (NH3) 0-20000 ppm with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.

6100AL1-0-1015/0100P
(7001)

RC SYSTEMS  6100AL1-0-1015/0100P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Ammonia (NH3) 0-100 to 0-1000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 