Calibration Technologies Gg-nh3-2-exp | Ammonia | Gas Detectors (general-purpose) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CALIBRATION TECHNOLOGIES   GG-NH3-2-EXP

CALIBRATION TECHNOLOGIES GG-NH3-2-EXP
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
CTI GasGuard NH3-2%-EXP Ammonia Catalytic Bead Sensor 0-2% (up to 20000 ppm) for gas leak detection in compressorrooms where E-stop or electrical shunt trip is desired. Explosion-proof. Enclosure and sensor head certified for hazardous locations. Industry standard linear 4-20 mA output. Power: 24 VDC, 120 mA. NEC, UL, CSA, FM and IEC Approvals.
Available in November 2015

GG-NH3-2-EXP   
1,786.74

Relay Output
RM420 Relay Output

   In Stock  ]
Key Features

  • Explosion-proof enclosure for classified areas
  • 0/2% (20,000 ppm) range
  • No zero signal drift
  • Electronics potted to eliminate internal corrosion
  • Ammonia selective catalytic bead sensor technology
  • Industry standard linear 4/20 mA output
  • Corrosion, weather and chemical resistant fiberglass composite sensor enclosure
  • Operating temperature from -40°F to +120°F
  • Accurately monitor explosive NH3 levels for emergency response situations
  • Real-time continuous monitoring for early leak detection.
  • Sensing element designed for long life in harsh industrial environments

The GasGuard NH3-2%-EXP is designed to detect and monitor potentially explosive levels of ammonia vapors in the event of a catastrophic failure. Most codes specify an electrical shunt-trip at a level not higher than 25% LEL to remove potential ignition sources in the event of a serious ammonia leak. The GasGuard NH3-2%-EXP allows for an earlier trip level of 12.5%LEL.

The GasGuard NH3-2%-EXP utilizes an ammonia selective catalytic bead sensor technology with a matched pair of detector elements. When ammonia vapors enter the sensor, the passive bead remains un- changed while the active detector bead catalyzes the oxidation of gas, generating heat and changing its resistance. The resulting change in resistance is accurately measured across the bridge circuit.

The GasGuard NH3-2%-EXP provides an industry standard linear 4/20 mA output signal proportional to 0-2% (20,000 ppm) of ammonia. Long sensor life with minimal span adjustment can be expected in most mechanical room applications. The sensor is designed for simple calibration and is field replaceable.

Applications

  • Compressor Rooms
  • Electrical shutdown
  • Heat Treatment
  • Tank Rooms
  • Sea Vessels
  • Refrigeration Systems
  • Cold Storage
  • Pulp and Paper
  • Chemical Plants
  • Breweries
  • Refineries
Benefits

  • Low cost explosion protection
  • Long sensor life (5 yrs typical)
  • Simple operation & calibration

Since low-ppm sensors can’t detect high enough and high-ppm sensors can’t detect accurately at low levels, the use of the GasGuard NH3-2%-EXP sensor in conjunction with low-ppm GasGuard NH3- EXP sensors ensures a second-stage line of defense in the event of a serious ammonia leak. Intended for electrical shutdown, it provides protection against potentially explosive situations.

Typical sensor life is 5-7 years, with minimal to no cross-sensitivity to most other gases. Field replaceable sensor element keeps long term maintenance simple and low cost.

Every circuit board is potted to completely eliminate corrosion to the electronic components and copper tracing on the circuit board. An explosion-proof aluminum enclosure houses and houses the transmitter.

The GasGuard NH3-2%-EXP is delivered factory calibrated and ready to install. The assembly includes sensor, transmitter and explosion-proof enclosure. Use the model numbers below to order.

Specifications
DETECTION PRINCIPLE: Catalytic Bead
DETECTION METHOD: Diffusion
GASES: Ammonia (NH3)
RANGES: 0-2% (20,000 ppm)
OUTPUT SIGNAL: Linear 4/20 mA (max input impedance: 700 Ohms)
POWER SUPPLY: +24 VDC, 120 mA
SENSITIVITY: 200 ppm with 1,000 ppm zero deadband
TEMPERATURE RANGE: -40°F to +150°F (-40°C to +66°C)
HUMIDITY RANGE: 5% to 100% condensing
RESPONSE TIME: T50 = less than 20 seconds
T90 = less than 45 seconds
ACCURACY: +/- 5% of value, but dependant on calibration gas accuracy
ZERO DRIFT: Less than 0.01% full-scale per month
SPAN DRIFT: Generally less than 1% full-scale per month
REPEATABILITY: +/- 1% of full-scale
LINEARITY: +/- 1% of full-scale
WIRING CONNECTIONS: 3 conductor, shielded, stranded, 20 AWG cable (Belden 8772 or equivalent) up to 1500 ft.
ENCLOSURE: Body and cover: Aluminum.
Certification and compliances:
NEC/CEC:
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
NEMA/EEMAC: 3, 4, 4X, 7BCD, 9EFG
UL Standard: 1203
CSA Standard: C22.2 No. 30
FM Classification No.: 3615
IEC Standards EN:60079-0, EN:60079-1, EN:60529
Sensor head: Stainless steel
CESI01ATEX066U (component certificate)
Standard ATEX marking: II 2G Ex d IIC Gb
DIMENSIONS: 7” high x 5.25” wide x 4.75” deep
WEIGHT: 5 lbs
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    10 Items found.
CK-Cup-Hose
(2982)

CALIBRATION TECHNOLOGIES  CK-Cup-Hose

Standard cup, large cup & 3 ft hose



$35.89 
CK-CUPSET
(7107)

CALIBRATION TECHNOLOGIES  CK-CUPSET

Cup Set, Calibration Fits Sensor Diameters 0.625, 0.875, 1, 1.25, 1.75 (inches)



$59.17 
RM420-LR
(5805)

CALIBRATION TECHNOLOGIES  RM420-LR

Calibration Technologies Adjustable Setpoint Relay, 24Vdc 4-20mA to relay module, fail-safe relay output to any 4-20 mA device. SPDT relay, Form C contacts.



$193.03 
SHA-024-B
(2987)

CALIBRATION TECHNOLOGIES  SHA-024-B

CTI SHA-24 100dB Horn/Strobe 24 VDC. White body and blue lens. With weather proof mounting backbox. UL1638 approved.

Configure

$226.01 
SHA-120-B
(2988)

CALIBRATION TECHNOLOGIES  SHA-120-B

CTI SHA-120 99dB Horn/Strobe 120 VAC. White body and blue lens. With weather proof mounting backbox. UL Listed. NEMA 4X enclosure.

Configure

$253.17 
SHA-PY-120-B
(7080)

CALIBRATION TECHNOLOGIES  SHA-PY-120-B

CTI SHA-PY-120 Horn and Strobe. Weather-proof. 120 VAC. Two or three wire connection. High intensity 5 Joules Xenon flash and 8 selectable horn tones. Wall or ceiling mount. NEMA 4X. UL listed.

Configure

$329.80 
SL3-_24-R____-B
(6570)

CALIBRATION TECHNOLOGIES  SL3-24-R-B

CTI SL3 LED stack light with 105 dB buzzer. Up to 5 24VDC or 120VAC Flashing light modules (62 fpm). Polycarbonate Housing. 1/2" NPT conduit. IP66. NEMA 4X. UL listed.

Configure

$446.20 
EM2-24
(2971)

CALIBRATION TECHNOLOGIES  EM2-24

CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

Configure

$615.95 
GG-2
(2972)

CALIBRATION TECHNOLOGIES  GG-2

CTI GasGuardian 2 2-Channel Controller/Alarm Panel for simultaneously monitor of two sensor locations. 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.



$2,027.30 
GG-6
(2973)

CALIBRATION TECHNOLOGIES  GG-6

CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

Configure

$4,062.36 
> AMMONIA :    42 Items found.
ECFX-200-N
(6467)

HONEYWELL  ECFX-200-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-200 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,596.46 
LBW-420-1-SS
(912)

COOL AIR  LBW-420-1-SS

Cool Air LBW-420 Ammonia (NH3) 0-100/1000ppm Gas Leak Detector 4-20mA analog output. NEMA 4X enclosure. Alarm, pre-alarm and auxiliary relays. 115/230 VAC, 50/60 Hz, or 24 VDC. User Adjustable ranges: 0-100, 0-250, 0-500 and 0-1000ppm

Configure

$1,631.80 
100-0008-SS/100-0015-NH3
(4759)

ESP SAFETY  100-0008-SS/100-0015-NH3

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Ammonia (NH3) 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,653.30 
ECFX-1000-N
(6587)

HONEYWELL  ECFX-1000-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-1000 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,654.94 
LBW-420-LEL-DC-01
(6055)

COOL AIR  LBW-420-LEL-DC-01

Cool Air LBW-420-LEL Ammonia (NH3) 0-9.9% Gas Leak Detector. Includes 4-20mA analog output, 3 latching relays and LED Display. 18-36 VDC (Optional AC). NEMA 4X and UL listed enclosure.

Configure

$1,676.90 
ECFX-500-N
(6468)

HONEYWELL  ECFX-500-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-500 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

2100AL-0-9012/0300P/L0
(132)

RC SYSTEMS  2100AL-0-9012/0300P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,789.61 
LBW-HHS-II
(1556)

COOL AIR  LBW-HHS-II

Cool Air LBW-HHS-II Portable Handheld Ammonia (NH3) Leak Detector. Glass Filled Polycarbonate Housing. Includes touch-sensitive LCD display, 3 concentration alarms (caution, warning and danger), USB output, RS-232 Output Cable, 4GB of internal memory and rechargeable NiMH battery.

Configure

$1,820.40 
VL-F7-NH3-N4-LPA-NO
(3720)

HONEYWELL  VL-F7-NH3-N4-LPA-NO

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). Continuos monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2” cast steel “T”. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp.



 
S3KUL2-XNXXSA1SS
(685)

HONEYWELL  S3KUL2-XNXXSA1SS

Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring AMMONIA (NH3) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-200ppm, 0-1000ppm. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,837.05 
961-500026-100G
(6349)

DETCON  961-500026-100G

Detcon DM-102-NH3 Electrochemical Ammonia (NH3) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. Optional 316 Stainless Steel Housing. 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

ECFX-250-N
(6588)

HONEYWELL  ECFX-250-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-250 with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
ECFX-100-N
(1516)

HONEYWELL  ECFX-100-N

Honeywell Analytics Manning EC-FX gas detector with electrochemical sensor for Ammonia (NH3) 0-100 ppm with Isolated 3-wire 4-20 mA and RS-485 Modbus RTU outputs, 24VDC Power, NEMA-1 enclosure.

Configure

$1,898.10 
SPXCDULNA2
(1897)

HONEYWELL  SPXCDULNA2

Honeywell Sensepoint XCD RTD Gas Detector for Ammonia (NH3) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,920.63 
31001AL-0-9012/0300P/L0
(6888)

RC SYSTEMS  31001AL-0-9012/0300P/L0

RC Systems SenSmart 3100 3 wire gas detector for Ammonia (NH3) 0-300ppm to 0-1000ppm with Electrochemical sensor 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. Suitable for Class I Div 2 (Non-Incendive).

Configure

$1,967.53 
967-505090-100
(6070)

DETCON  967-505090-100

Detcon DM-702-NH3 Electrochemical Smart Ammonia (NH3) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

VL-F7-NH3-N4-LPA-MK
(3716)

HONEYWELL  VL-F7-NH3-N4-LPA-MK

Honeywell Analytics Manning Vent Line (VL) leak detector for Ammonia (NH3) 0-10000ppm (1%). continuous monitoring. Can be connected to and monitored by all Honeywell Analytics readouts. 2" cast steel T. 4-20mA output. NEMA 4 Enclosure. Linear pre-amp. Includes mounting kit



 
XNXUTAENNNNN-XNXXSA1SS
(835)

HONEYWELL  XNXUTAENNNNN-XNXXSA1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Ammonia (NH3) compatible with all Honeywell gas sensing technologies, with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-200ppm, 0-1000ppm

Configure

$2,251.86 
IR-F9-NH3-0/2-N1
(1548)

HONEYWELL  IR-F9-NH3-0/2-N1

Honeywell Analytics Manning Airscan IR-F9 gas detector with Infrared sensor for Ammonia (NH3) 0-20000 ppm with 4-20 mA output, 24VDC Power, NEMA-1 enclosure.

6100AL1-0-1015/0100P
(7001)

RC SYSTEMS  6100AL1-0-1015/0100P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Ammonia (NH3) 0-100 to 0-1000ppm with 'ST-44' smart transmitter and GEN2 smart Electrochemical sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. Suitable for Class I Div 2 (Non-Incendive). IP66.

Configure

$2,389.61 