Calibration Technologies Gg-h2-ec-10000-exp | Hydrogen | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

CALIBRATION TECHNOLOGIES   GG-H2-EC-10000-EXP

CALIBRATION TECHNOLOGIES GG-H2-EC-10000-EXP
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
CTI GG-H2-EC-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen (H2) 0-2000 ppm and 0-10000 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

GG-H2-EC-10000-EXP   
1,341.51

Gas Range
Relay Output
RM420 Relay Output

   In Stock  ]
2 Variants of base SKU
Key Features
  • Explosion-proof enclosure for classified areas
  • Hydrogen selective electrochemical sensor technology
  • 0-2,000 ppm and 0-10,000 ppm ranges
  • Electronics potted to eliminate internal corrosion
  • Industry standard 24VDC, linear 4-20 mA output
  • Operating temperature from -4°F to +122°F
  • Accurately monitor H2 levels for personnel protection
  • No false alarms from interference gases
  • Real-time continuous monitoring for early leak detection

The GG-H2-EC-EXP is designed for detection of potentially explosive hydrogen gas in hazardous areas. The standard detection range of 0-10,000 ppm provides accurate concentra- tions and the ability to react before the levels reach the LEL. An alternate range of 0-2,000 ppm is also available for other applications.

The GG-H2-EC-EXP utilizes a proven hydrogen specifc electrochemical sensor for detecting hydrogen gas concentrations. No false alarms due to cross-sensitivities from other gases, and no false alarms from temperature or humidity fluctuations.

The GG-H2-ECEXP provides an industry standard linear 4/20 mA output signal proportional to ppm concentration of hydrogen. Long sensor life with minimal span adjustment can be expected in most battery room applications. The sensor is designed for simple calibration and the sensor head is easily field replaceable.

Applications
  • Battery Charging Rooms
  • Perimeter Monitoring
  • Steel Industry
  • Heat Treatment
  • Refineries
  • Sea Vessels
Benefits
  • Low cost explosion protection
  • No false alarms from interference gases
  • Simple operation & calibration

The International Fire Code section 608.6.1 states “the ventilation system shall be designed to limit the maximum concentration of hydrogen to 1% (25%LEL) of the total volume of the room” or “continuous ventilation shall be provided at a rate of not less than 1 cfm per square foot of floor area in the room”.

Hydrogen gas is much lighter than air and will tend to accumulate in areas by the ceiling. For optimum detection, mount the sensor at a height not lower than a few feet from the highest point in the room, keeping accessibility in mind. As a general rule of thumb, try to mount sensors within 30 feet of potential H2 sources.

The GG-H2-EC-EXP is useful for ventilation activation, and also for alarm outputs such as horn/strobes, phone dialers and other alarm functions.

Typical sensor element life is 3 years, with minimal cross-sensitivity to other gases. Field replaceable sensor element keeps long term maintenance simple and low cost. Every circuit board is potted to completely eliminate corrosion to the electronic components and copper tracing.

SPECIFICATIONS
Input Power:+24 VDC, 50 mA
Detection Principle:Electrochemical
Detection Method:Diffusion
Gases:Hydrogen (H2)
Range:0-2,000 ppm
0-10,000 ppm (standard) (1% Vol (25%LEL))
Output Signal:Linear 4/20 mA (max input impedance: 700 Ohms)
Linearity:+/- 0.5% of full-scale
Repeatability:+/- 1% of full-scale
Response Time:T50 = less than 10 seconds
T90 = less than 20 seconds
Accuracy:+/- 5% of full-scale
Zero Drift:Less than 0.1% of full-scale per month, non- cumulative
Span Drift:Application dependent, but generally less than 3% per month
Temperature Range:-4°F to +122°F (-20°C to +50°C)
Humidity Range:5% to 95% non-condensing
Wiring Connections:3 conductor, shielded, stranded, 20 AWG cable (General Cable C2525A or equivalent) up to 1500 ft
Terminal Block Plugs: (Field Wiring)26-12 AWG, torque 4 lbs-in
Weight:3.75 lbs
Dimensions:6.75” high x 5.25” wide x 4.5” deep
Enclosure:Copper-free aluminum body, epoxy powder coat finish, neoprene gasket, for hazardous areas.
NEC/CEC:
Class I, Division 1 & 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
NEMA/EEMAC: 3, 4, 4X, 7BCD, 9EFG
UL Standard: 1203
CSA Standard: C22.2 No. 30
FM Classification No.: 3615
ATEX Certificate KEMA 02 ATEX 2265U
IEC Standards EN:60079-0, EN:60079-1, EN:60529
Warranty:2 years (including sensor element)
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    5 Items found.
CK-CUPSET
(7107)

CALIBRATION TECHNOLOGIES  CK-CUPSET

Cup Set, Calibration Fits Sensor Diameters 0.625, 0.875, 1, 1.25, 1.75 (inches)



$59.17 
RM420-LR
(5805)

CALIBRATION TECHNOLOGIES  RM420-LR

Calibration Technologies Adjustable Setpoint Relay, 24Vdc 4-20mA to relay module, fail-safe relay output to any 4-20 mA device. SPDT relay, Form C contacts.



$193.03 
EM2-24
(2971)

CALIBRATION TECHNOLOGIES  EM2-24

CTI EM2 Gas Detection Entrance Monitor Controller/Alarm Panel for stand-alone or feed-through applications. 8A SPDT relay, 3" LCD display, 4-20 mA input and NEMA 4X enclosure. IP68.

Configure

$615.95 
GG-2
(2972)

CALIBRATION TECHNOLOGIES  GG-2

CTI GasGuardian 2 2-Channel Controller/Alarm Panel for simultaneously monitor of two sensor locations. 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.



$2,027.30 
GG-6
(2973)

CALIBRATION TECHNOLOGIES  GG-6

CTI GasGuardian 6 6-Channel Controller/Alarm Panel for simultaneously monitor of up to 30 sensors (with expansion modules). 6 onboard relays, horn relay, alarm log, 4-20 mA input, LCD display and NEMA 4X enclosure designed for washdown and outdoors.

Configure

$4,062.36 
> HYDROGEN :    23 Items found.
967-848490-100
(6087)

DETCON  967-848490-100

Detcon DM-700-H2 Electrochemical Smart Hydrogen (H2) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

6100AL1-0-1019/0500P
(7005)

RC SYSTEMS  6100AL1-0-1019/0500P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen (H2) 0-500 to 0-2000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,876.62 
GG2SAXXX-X-H2
(5012)

ION SCIENCE  GG2SAXXX-X-H2

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Hydrogen (H2). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.