Detcon DM-700-O2 Electrochemical Smart Oxygen (O2) 0-25% Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

967-343490-25P   
Please Email us your request for quote   

Junction Box
Options
Integration Modules
Class 1; Div 1; Groups B, C, D – Zone I Group IIB+H2
Mounting Options
Additional Modules

   3 Weeks  ]
12 Variants of base SKU

Detcon Model DM-700-O 2 is a non-intrusive “Smart” sensor designed to detect and monitor Oxygen in air over the range of 0-25% by volume using electrochemical sensor technology. The plug-in, field replaceable sensor cell is temperature compensated and features over-sized gold-plated connections that help prevent corrosion. The Model 700’s rugged framework includes an intrinsically safe electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model 700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model 700 is equipped with standard analog 4-20mA, and ModbusTM RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon’s oxygen sensors have a long shelf life and are supported by an industry-leading warranty.

Features Failsafe User-Friendly Interface
  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics
Environmentally Bulletproof
  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port
Applications
  • Petrochemical
  • Refineries
  • Chemical plants
  • Confined Space Monitoring
  • Analyzer Shelters
  • Wastewater treatment plants
  • Wet wells-dry wells
  • Pulp and paper
  • Food and beverage
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
2-electrode electrochemical cell
Plug-in field replaceable Type
Sensor Life2 1/2 to 3 years typical
Measurement Range0-25% Oxygen by volume
Accuracy/Repeatability±1% FS
Response/Clearing TimeT90 ≤ 10 seconds
Span Drift<5% of signal per year (in first two years)
OutputsLinear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical ClassificationExplosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Class I, Zone 1, Group IIC
ATEX
II 2 G Ex d ib IIB + H2 T4 Gb (Tamb = -40°C to +50°C)
Ingress ProtectionNEMA 4X, IP66
Safety ApprovalsCCSAUS
ATEX
CE Marking
SIL2 Certified to IEC 61508
WarrantyPlug-in Cell - 2 years; Transmitter - 2 Years
Environmental Specifications
Operating Temperature Range-40°F to +122°F; -40°C to +50°C
Storage Temperature Range-40°F to +122°F; -40°C to +50°C
Operating Humidity Range0-99% RH non-condensing
Operating Pressure RangeAtmospheric ±10%
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5"; 140mm center to center
Weight2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input11-30 VDC
Power ConsumptionNormal operation = 30mA (<0.75 watt)
Maximum = 50mA (1.2 watts)
Inrush Current1.67A @ 24V
RFI/EMI ProtectionComplies with EN50270
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Serial RS-485 OutputRS-485 ModbusTM RTU
Baud Rate (optional)9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan
Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring, EMI/RFI Immunity
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    3 Items found.
943-000000-000
(6566)

DETCON  943-000000-000

Detcon Calibration Sleeve/Wind Guard for use with sensor splash guard for all Detcon sensor heads.



 
377-343401-025
(6162)

DETCON  377-343401-025

Detcon Oxygen plug-in sensor for DM-700-O2



 
S927-343400-25P
(6604)

DETCON  S927-343400-25P

Detcon DM-700-O2 Oxygen Deficiency ITM (Intelligent Transmitter Module) Spare Part.



 
> OXYGEN :    29 Items found.
41001AL-0-1010/0025P/L0
(7176)

RC SYSTEMS  41001AL-0-1010/0025P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Oxygen (O2) 0-25% vol with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1010/25V/L0
(7131)

RC SYSTEMS  51001AL-0-1010/25V/L0

RC Systems SenSmart 5100 3-wire gas detector for Oxygen (O2) 0-25% vol. with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
SPXCDULNO2
(5108)

HONEYWELL  SPXCDULNO2

Honeywell Sensepoint XCD RTD Gas Detector for Oxygen (O2) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 25% v/v. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
961-340026-025G
(6372)

DETCON  961-340026-025G

Detcon DM-100-O2 Electrochemical Oxygen (O2) 0-25%vol Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

2100AL-0-9010/25V/L0
(116)

RC SYSTEMS  2100AL-0-9010/25V/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
31001AL-0-9010/25V/L0
(5787)

RC SYSTEMS  31001AL-0-9010/25V/L0

RC Systems SenSmart 3100 3 wire gas detector for Oxygen (O2) 0-25% vol. with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
XNXUTAENNNNN-XNXXSO1SS
(849)

HONEYWELL  XNXUTAENNNNN-XNXXSO1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Oxygen (O2) 0-25%VOL compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2

Configure

$1,969.63 
6100AL1-0-1010/0025P
(7013)

RC SYSTEMS  6100AL1-0-1010/0025P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Oxygen (O2) 0-25% vol with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
GG2SAXXX-X-O2
(5019)

ION SCIENCE  GG2SAXXX-X-O2

Ion Science GasCheck G2 Micro Thermal Conductivity Leak Detector (MTCD) for Oxygen (O2). Rapid and accurate. LCD back lit display, LED indicator and audible sounder. Low cost operation. *** Phased Out replaced by Panther ***

Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.