Rc Systems 1200ald-109070/100p-l0 | Lel Catalytic Bead | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

RC SYSTEMS   1200ALD-109070/100P-L0

RC SYSTEMS 1200ALD-109070/100P-L0
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
RC Systems SenSmart 1200 gas detector for Hydrocarbons and Hydrogen, Catalytic Bead sensor (acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, isopropyl alcohol, methane, pentane, propane, propene or propylene) 0-100% LEL with 'ST-48' smart transmitter. 3-Wire Bridge Output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

1200ALD-109070/100P-L0   
1,218.18

Gas
Enclosure Type
Splash Guard

   3 Weeks  ]
12 Variants of base SKU

The RC Systems SenSmart 1200 is a 3-Wire Bridge Gas Detector available in a 316 stainless steel sensor head enclosure and Suitable for Class 1 Division 1 Groups A, B, C, D. These easy-to-install and maintain gas detectors must be connected to an R. C. Systems single or multi-channel receiver to add user calibration and readout functions.

The SenSmart 1200 utilizes our “bridge” sensors, including catalytic, acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, Isopropyl alcohol, methane, pentane, propane, propene, propylene and many other compounds. The 1200’s bridge output is compatible with R C Systems single and multi-channel receivers.

OEM Version of the GDS Corp. GDS-48

FEATURES HIGHLIGHT
  • Field swappable sensor module. Range and target gas configured on sensor module
  • Improves system noise immunity because low level sensor signals are protected within the sensor head
  • 316 SS sensor head model is Suitable for Class 1 Division 1 hazardous areas
  • Missing or failed sensor forces FAULT signal
  • Compatible with 1, 2, 4, 16 and 64 channel Receiver/Controllers (user calibration & readout are at the Receiver)

SPECIFICATIONS
Power Supply2VDC @ 300mA
Accuracy+/- 1% of full scale range (typical)
Standard Output3 wire bridge output
TempLess than .1% per degree C over ambient temperature range
Housing316 Stainless or aluminum enclosure suitable for Class 1 Groups A,B,C,D; Class 2, Groups E,F,G
ApprovalsSuitable for Class 1 Division 1 and Group A,B,C,D Exia.
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    16 Items found.
10-0203
(7043)

RC SYSTEMS  10-0203

RC SYSTEMS Sensor calibration cup adaptor for stainless steel / aluminum sensor heads



$95.71 
CYL-10305400
(3238)

PORTAGAS  CYL-10305400

Calibration Gas Hexane 40% LEL (4400 ppm) Balance Air Size 100 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder (Made by Portagas)

Configure

$124.51 
CYL-90302139
(1259)

PORTAGAS  CYL-90302139

Calibration Gas Butane (C4H10) 50% LEL (0.9%) Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10624200
(1305)

PORTAGAS  CYL-10624200

Calibration Gas Propane (C3H8) 50% LEL 1.06%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095187
(6713)

PORTAGAS  CYL-90095187

Calibration Gas Propane (C3H8) 50% LEL 1.1%Vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-10241000
(4296)

PORTAGAS  CYL-10241000

Calibration Gas Ethane (C2H6) 50% LEL 1.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90090227
(1313)

PORTAGAS  CYL-90090227

Calibration Gas Methane (CH4) 50% LEL 2.5% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90301910
(933)

PORTAGAS  CYL-90301910

Calibration Gas Hydrogen (H2), 50% LEL 2% vol Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095251
(2040)

PORTAGAS  CYL-90095251

Calibration Gas Methane (CH4) 60% LEL 3% vol. Balance Nitrogen, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90411390
(2927)

PORTAGAS  CYL-90411390

Calibration Gas Hydrogen (H2) 60% LEL 2.4% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
CYL-90095224
(2926)

PORTAGAS  CYL-90095224

Calibration Gas Methane (CH4) 60% LEL 3% vol. Balance Air, 100 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$124.51 
10-0552
(7028)

RC SYSTEMS  10-0552

Sample Draw Flow Cell Barrel Adapter for RC Systems Gen I and Gen II 10-0247 Sensor heads(Series 1000, 2000, 3000, 5000 and 6000) gas detectors) 1/8" NPT ports (1 inlet 1 outlet). Used with ST-44 and ST-48 Transmitters.



$213.06 
10-9070
(7091)

RC SYSTEMS  10-9070

RC Systems 10-9070/10-9071/10-9570/10-9571 Gen I Catalytic Bead Smart Sensor assembly for Series 1000, 2000, 3000, 5000, 6000 Gas Detectors with ST-44 & ST-48 transmitter, Methane/Hydrocarbons 0-100% LEL

Configure

$536.36 
90-01
(3243)

RC SYSTEMS  90-01

RC Systems ViewSmart 200 2-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 2 x 3-wire bridge or 2 x 4-20mA input channels board.

Configure

$2,820.78 
90-50
(1642)

RC SYSTEMS  90-50

RC Systems ViewSmart 400 4-Channel Gas Detector Integral Alarm Controller with standard 2x 5A SPDT relays, with 6 x optional alarm relays, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure. 120VAC or 24VDC power supply. Modbus interface. Optional 4 x 3-wire bridge or 4 x 4-20mA input channels board.

Configure

$3,525.97 
ST-72-02
(6921)

RC SYSTEMS  ST-72-02

RC Systems ViewSmart 6400 Digital Gas Detection CONTROLLER with 16, 32, 48 or 64 channels and LCD display of 320x240 pixels. Centralize display and alarm functions. UL and CSA approved for Class I, Division 2, 2 standard Master/Slave RS485 ports and Modbus TCP Client/Server port with web server included. Standard SPDT 5A relays for HORN and FAULT, plus 3 programmable alarm relays included. NEMA 4X, NEMA 4X Stainless Steel, full 19" Rack mount and NEMA 7 wall-mount options. Optional 4-20mA inputs.

Configure

$12,179.52 
> LEL CATALYTIC BEAD :    27 Items found.
52001AL-0-9070/100P/L0
(7121)

RC SYSTEMS  52001AL-0-9070/100P/L0

RC Systems SenSmart 5200 3-wire gas detector with Catalytic Bead sensor for Hydrocarbons and Hydrogen (ammonia, butane, ethane, ethanol, hexane, hydrogen, Isopropyl alcohol, pentane, propane, propene, propylene) 0-100% LEL with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
XNXUTAVNNCB1
(852)

HONEYWELL  XNXUTAVNNCB1

Honeywell XNX Universal Gas Detector Transmitter including MPD CATALYTIC BEAD sensor combustible 0-100% LEL (Lower Explosive Limit) Methane (Natural Gas). Backlit LCD Display, HART® over 4-20mA output,UL/CSA approved, 5 x 3/4"NPT entries and painted Aluminum. UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2, INMETRO

Configure

$1,728.46 
XCDRFDL
(3004)

HONEYWELL  XCDRFDL

Honeywell Sensepoint XCD RFD (Remote Flammable Detector) Kit. Includes transmitter with LM25, 3/4“NPT Entry, 705 sensor, and 3 wire junction box. Tri-colour backit display. Outputs include 2 programmable alarm relays, 1 programmable fault relay, 4-20mAoutput (sink or source selectable). Sensor can be mounted up to 30 metres (100 feet) from transmitter. cCSAus Certified for North America. Class 1, Div 1, Groups B, C, & D.

Configure

$1,734.98 
967-521520-100
(5005)

DETCON  967-521520-100

Detcon FP-700 non-intrusive Smart Sensor designed to detect and monitor combustible gases with range 0-100% LEL using catalytic bead sensor technology. Aluminum or Stainless Steel Junction Box. 4-20mA and Modbus RS-485 outputs. LED Display. Explosion Proof. IP66. CSA, ATEX, CE and SIL2 Approved.

966-524520-100
(6100)

DETCON  966-524520-100

Detcon FP-624D Combustible 0-100% LEL Smart Sensor with catalytic bead. Includes detector in stainless steel housing, base connector board, explosion proof enclosure, splashguard, 4-20 mA output, RS-485 serial communication and 3 alarm relays. IP66. CSA approval for Class I, Division 1, Groups C & D.

32001AL-0-9071/100P/L0
(6894)

RC SYSTEMS  32001AL-0-9071/100P/L0

RC Systems SenSmart 3200 3 wire gas detector with Catalytic Bead sensor for Hydrocarbons and Hydrogen (ammonia, butane, ethane, ethanol, hexane, hydrogen, Isopropyl alcohol, pentane, propane, propene, propylene) 0-100% LEL with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,967.53 
6200AL1-0-109070/100P
(7019)

RC SYSTEMS  6200AL1-0-109070/100P

RC Systems SenSmart 6200 3 wire Dual Channel Gas Detector for Hydrocarbons and Hydrogen Catalytic Bead sensor (acetylene, ammonia, butane, ethane, ethanol, hexane, hydrogen, isopropyl alcohol, methane, pentane, propane, propene or propylene) 0-100% LEL with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.