Honeywell S3kul2-xnxxsh1ss | Hydrogen Sulfide | Gas Detectors (explosion-proof) | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

HONEYWELL   S3KUL2-XNXXSH1SS

HONEYWELL S3KUL2-XNXXSH1SS
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum housing (optional stainless steel) for monitoring HYDROGEN SULFIDE (H2S) with electrochemical sensor, 2-wire 4-20mA loop, LCD Display. Optional ranges: 0-15ppm, 0-100ppm Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

S3KUL2-XNXXSH1SS   
1,491.53

Gas Range
Agency Approval/Enclosure
Splash Guard
Custom Tag

   11 Weeks  ]
18 Variants of base SKU
Honeywell Series 3000 Display
FEATURES

Reliable detection
  • Proven electrochemical sensing technology
  • Uses Surecell™ electrochemical cells, ideal for hot and humid environments
  • Long life sensing elements (typical >2 years)
  • Patented 'Reflex' sensing elemen verification diagnostics
Reduced installation costs
  • Universal mounting bracket included, supplied as standard
  • Explosion proof transmitter allows field wiring to be run along with other non IS instruments
  • Plug-in sensor removes wiring
Reduced commissioning costs
  • Sensor recognition software auto configures transmitter
  • Non-intrusive configuration
  • Plug and play factory configured sensors
Reduced maintenance costs
  • IS sensor connection permits hot swap, reducing down time
  • User programmable calibration frequency
  • Integral fault diagnostic software
  • Menu/icon driven calibration procedure
  • IP 66 rated to protect against dust/water ingress
Regulatory compliance
  • US (UL)
  • Canadian (cUL/CSA)
  • International (IECEx)
  • European (ATEX)
Range of optional accessories
  • Remote sensor mounting kit
  • Duct mounting kit (for H2, CO and H2S only)
  • Calibration cup to apply test gas
  • Collecting cone (for H2 and CO only)
Typical applications
  • Exploration and drilling platforms
  • Production platforms
  • Onshore oil and gas terminals
  • Refineries and chemical plants
  • Power plants
  • Waste water facilities
  • Utilities
Honeywell Series 3000 components

The Series 3000 MkII provides comprehensive monitoring of toxic and oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. This low powered gas detector operates on an industry standard 2-wire 4-20mA loop, making it ideal for both new and retrofit applications. Users can configure the detector without the need of a ‘hot work permit’ by using the LCD and magnetic switches. Fault diagnostic software and configurable calibration intervals simplify maintenance procedures.

The Intrinsically Safe smart sensors are supplied pre-configured and can be ‘hot swapped’ without having to remove power to the detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensor to be mounted up to 50’ (15m) from the transmitter, making it ideal for operation in areas that are difficult to access.

Series 3000 MkII is supplied with all necessary accessories for easy installation. The detector can be mounted on a wall or support pole using the universal bracket provided. Electrical installation can be made using either conduit or cable with suitable mechanical protection. A ¾” NPT entry and M20 adapter are included as standard. A weatherproof cap is also included for use in the harshest outdoor conditions.

Detectable Gas
Gas Formula Selectable Full Default Range Default Range Operating Temperature**
Min Max
Hydrogen Fluoride H2S 10.0 to 50.0ppm 15.0ppm -40°C / -40°F 55°C / 131°F
Series 3000 MkII Detector
Use Rugged and reliable gas detector for the protection of personnel from toxic and Oxygen gas hazards. Suitable for use in Zone 1 or 2 hazardous areas and North American Class I and II Division 1 or 2 areas.
Electrical
Connections and Power 2-wire loop powered
17VDC (+ / -10%) to 24VDC (max) operation
22mA max. over range
Signal 2-wire with screen (90% coverage) or conduit
0.5mm2 (20AWG) to 2.0mm2 (14AWG)
Connections and Power 0-100% FSD 4-20mA
Fault = 3mA
Calibration due selectable off or 3mA
Max. over range 22mA
Inhibit (toxic sensors) = Selectable 3mA or 4mA Inhibit
(Oxygen sensors) = Selectable 3mA or 17.4mA
Construction
Material Transmitter: Epoxy painted aluminium alloy LM25 or 316 Stainless Steel
Sensor: 316 Stainless Steel with PTFE filter
Maximum Dimensions 164mm x 201mm x 99mm
6.4" x 7.9" x 3.9"
Weight Aluminium alloy LM25: 1.7kg (3.75lbs.) Stainless Steel 316: 3.7kg (8.16lbs.)
Environmental
IP Rating IP66 (EN 60529), NEMA 4X
Certified Temperature ATEX/IECEX: -20°C to +55°C (-4°F to +131°F)
UL/c-UL: -40°C to +55°C (-40°F to +131°F)
Operating Humidity Continuous 20-90% RH (non-condensing)
Intermittent 0-99% RH (non-condensing)
Operating Pressure 90-110kPa
Storage Conditions 15°C to 30°C (59°F to 86°F) 30-70% RH (non-condensing)
Certification UL/c-UL Class I, Div 1 & 2, Groups B, C & D; Class II, Div 1, Groups E, F, G; Class II, Div 2, Groups F & G, Class I Zone 1, Group 2B + H2 Hazardous Locations
ATEX: II 2 (1) G Ex d [ia] IIB+H2 T4 (Tamb -20°C to +55°C / -4°F to 131°F)
IECEx Ex d [ia] IIB + H2 T4
Approvals CE compliant in accordance with:
ATEX Directive 94/9/EC
EMC Directive 2004/108/EC
EN 50270
Export Info
Made inUnited States
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    14 Items found.
S3KCAL
(715)

HONEYWELL  S3KCAL

Calibration cup (flow adaptor) for Honeywell Series 3000 transmitters. (for use with XNX EC sensors)



$117.16 
CYL-10338750
(1743)

PORTAGAS  CYL-10338750

Calibration Gas Hydrogen Sulfide (H2S) 500 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-10338000
(1292)

PORTAGAS  CYL-10338000

Calibration Gas Hydrogen Sulfide (H2S) 100 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-10326000
(1290)

PORTAGAS  CYL-10326000

Calibration Gas Hydrogen Sulfide (H2S) 20 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-10332000
(683)

PORTAGAS  CYL-10332000

Calibration Gas Hydrogen Sulfide (H2S) 50 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-90099192
(311)

PORTAGAS  CYL-90099192

Calibration Gas Hydrogen Sulfide (H2S) 300 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-10321000
(310)

PORTAGAS  CYL-10321000

Calibration Gas Hydrogen Sulfide (H2S) 10 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
(261)

GDS  10-0263

GDS Intrinsically safe IS barrier for GASMAX II and GASMAX EC. Model MTL 7787P+ or equivalent



 
S3KDMK
(718)

HONEYWELL  S3KDMK

Duct mounting kit for Honeywell Series 3000 & XNX transmitters. (Requires 1226A0382 for MPD sensor-mV type XNX)



$377.40 
S3KH1SS
(709)

HONEYWELL  S3KH1SS

Replacement Sensor Cartridge for Hydrogen Sulfide (H2S) S3000 transmitter 0-15ppm, user adjustable (10 to 50ppm, 1ppm increments)



$414.72 
S3KH2SS
(708)

HONEYWELL  S3KH2SS

Replacement Sensor Cartridge for Hydrogen Sulfide (H2S) S3000 transmitter 0-100ppm, user adjustable (50 to 500ppm, 10ppm increments)



$435.46 
S3KXSH1SS
(4091)

HONEYWELL  S3KXSH1SS

Replacement Sensor Assembly for Hydrogen Sulfide (H2S) S3000 MkIII transmitter 0-15ppm, user adjustable (10 to 50ppm, 1ppm increments)



$678.07 
S3KRMK
(716)

HONEYWELL  S3KRMK

Remote sensor mounting kit for Honeywell Series 3000 transmitters.

Configure

$700.84 
S3KXSH2SS
(4206)

HONEYWELL  S3KXSH2SS

Replacement Sensor Assembly for Hydrogen Sulfide (H2S) S3000 MkIII transmitter 0-100ppm, user adjustable (50 to 500ppm, 10ppm increments)



$725.76 
> HYDROGEN SULFIDE :    38 Items found.
2106B1400
(1451)

HONEYWELL  2106B1400

Honeywell Sieger Sensepoint Gas Detector Transmitter for Hydrogen Sulfide (H2S) (0-20 ppm to 0-100 ppm) with Surecell Toxic Sensor. 2 wire 4-20mA loop output. ATEX/IECEx CSA Class I Division 2 Certified.

Configure

$1,135.98 
1100ALD-109022/0010P-L0
(6914)

RC SYSTEMS  1100ALD-109022/0010P-L0

RC Systems SenSmart 1100 gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with 'ST-48' smart transmitter. Electrochemical sensor. 2-Wire 4-20mA output. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1 (Explosion Proof).

Configure

$1,314.28 
GG-H2S-50-EXP
(5979)

CALIBRATION TECHNOLOGIES  GG-H2S-50-EXP

CTI GG-H2S-50-EXP Explosion Proof Electrochemical Gas Sensor for Hydrogen Sulfide (H2S) 0-50 ppm. 4-20 mA output, 24VDC power supply. Explosion Proof Copper-free aluminum enclosure for Class l, Div 1 & 2, Groups B, C & D. CSA, UL, FM, ATEX and IECEx approved.

Configure

$1,341.51 
SPXCDULNHX
(663)

HONEYWELL  SPXCDULNHX

Honeywell XCD Sensepoint Gas Detector, Hydrogen Sulfide (H2S) Electrochemical Sensor with aluminium housing (optional stainless steel), stainless steel sensor head, tri-color backlit LCD Display, explosion-proof IP66 for hydrogen sulfide (H2S) 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay, 4-20mA output (sink or source selectable); Modbus RTU option available. 0-50 ppm range. User-Selectable full scale range 10.0 to 100.0ppm. UL/CSA Class I Division 1 or ATEX (Zone 1) IECEx available.

Configure

$1,379.12 
965-015420-100
(5007)

DETCON  965-015420-100

Detcon MicroSafe TP-524D Smart gas detection Sensor designed to detect and monitor Hydrogen Sulfide (H2S) with range 0-100ppm using solid state metal oxide semiconductor technology. Aluminum Junction Box. 4-20mA output. LED Display. Explosion Proof. IP66. ATEX, ISA and CE Approved. CSA and FM Approved for Class I, Division 1, Groups B, C, & D.

100-0008-SS/100-0015-H2S
(4754)

ESP SAFETY  100-0008-SS/100-0015-H2S

ESP Safety Vector 2-channel gas detector controller with smart Plug-In sensor included to detect Hydrogen Sulfide (H2S) 0-20, 0-50 or 0-100ppm. Operates as a stand-alone display for a variety of ESP sensors which can be remotely located up to 500 feet away over 4-wire RS-485. Sensor head can also be attached. Includes analog 4-20 current loop with HART, Digital RS-485 Modbus RTU and 4 relays. 96-Character OLED Screen. 316 Stainless Steel or Aluminum Explosion-proof housing. IP67. SIL 2, FM/CSA Class I Division 1 certification. Optional 2nd sensor available.

Configure

$1,440.00 
41001AL-0-1022/0005P/L0
(7167)

RC SYSTEMS  41001AL-0-1022/0005P/L0

RC Systems SenSmart 4100 2-wire 4-20mA loop powered gas detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with GEN 2 smart Electrochemical sensor. Includes LCD Display. 10-30 VDC, Two flashing Alarm LEDs. Aluminum, Stainless Steel or non-metallic enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,538.96 
51001AL-0-1022/0005P/L0
(7122)

RC SYSTEMS  51001AL-0-1022/0005P/L0

RC Systems SenSmart 5100 3-wire gas detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with GEN2 smart sensor, Color backlit LCD Display and 4-20mA output, 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA Class I Division 1 (Explosion-Proof). Optional 2 RS-485 Modbus ports, 2 Programmable Alarm and Fault Relays.

Configure

$1,594.80 
961-240026-100G
(2132)

DETCON  961-240026-100G

Detcon DM-100-H2S Electrochemical Hydrogen Sulfide (H2S) 0-100ppm Sensor Assembly with optional loop powered display. 4-20 mA. Features intelligent electronices, non-intrusive operator interface and comprehensive fault diagnostics. 316 Stainless Steel Housing with 3/4" NPT thread. XP-instrinsically safe. Class I, Div. 1, Groups A, B, C, & D.

967-242490-100
(6064)

DETCON  967-242490-100

Detcon DM-700-H2S Electrochemical Smart Hydrogen Sulfide (H2S) 0-100 ppm Sensor Assembly with LED display. 4-20mA and Modbus RS-485 outputs. 316 Stainless Steel Housing. Water Proof, Corrosion Proof, Vibration Proof and Explosion proof. NEMA 4X. IP66. Class I, Div. 1, Groups B, C, & D. CSA and ATEX approvals.

SPXCDULNH2
(5104)

HONEYWELL  SPXCDULNH2

Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen Sulfide (H2S) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

Configure

$1,735.82 
967-011520-100
(4717)

DETCON  967-011520-100

Detcon TP-700 non-intrusive Smart Sensor for Hydrogen Sulfide (H2S) 0-100ppm using a solid state metal oxide semiconductor MOS technology. Aluminum or Stainless Steel Junction Box. 4-20mA and Modbus RS-485 outputs. LED Display. Explosion Proof. IP66. CSA, ATEX, CE and SIL2 Approved.

2100AL-0-9022/0010P/L0
(126)

RC SYSTEMS  2100AL-0-9022/0010P/L0

RC Systems SenSmart 2100 2 wire 4-20mA Loop Powered gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output. 10-30 VDC. Stainless steel or aluminum enclosure. CSA certified for Class 1 Div 1 & 2 (Explosion Proof).

Configure

$1,789.61 
966-014520-100
(6101)

DETCON  966-014520-100

Detcon TP-624D Hydrogen Sulfide (H2S) 0-100ppm Smart Sensor with solid state metal oxide semiconductor technology. Includes MOS detector in stainless steel housing, base connector board, explosion proof enclosure, splashguard, 4-20 mA output, RS-485 serial communication and 3 alarm relays. IP66. ATEX and CSA approval for Class I, Division 1, Groups B, C & D.

XNXUTAENNNNN-XNXXSH1SS
(846)

HONEYWELL  XNXUTAENNNNN-XNXXSH1SS

Honeywell XNX Universal Gas Detector Transmitter for monitoring Hydrogen Sulfide (H2S) compatible with all Honeywell gas sensing technologies with aluminum housing. 3-wire 4-20mA HART loop, backlit LCD Display, option for Modbus, Foundation H1 Fieldbus, local Hart and relay outputs UL Certified Class 1, Div 1 Groups A, B, C, D / ATEX Zone 1, SIL-2. Optional ranges: 0-15ppm, 0-100ppm

Configure

$1,963.60 
31001AL-0-9022/0010P/L0
(5784)

RC SYSTEMS  31001AL-0-9022/0010P/L0

RC Systems SenSmart 3100 3 wire gas detector for Hydrogen Sulfide (H2S) 0-10ppm to 0-2000ppm with 'ST-48' smart transmitter. Includes Graphic LCD Display, LED indicator and 4-20mA output, optional alarm relays and Modbus RTU. 10-30 VDC. Aluminum or Stainless Steel enclosure. CSA certified for Class 1 Div 1(Explosion Proof).

Configure

$1,967.53 
6100AL1-0-1022/0005P
(7009)

RC SYSTEMS  6100AL1-0-1022/0005P

RC Systems SenSmart 6100 3 wire Dual Channel Gas Detector for Hydrogen Sulfide (H2S) 0-1 to 0-2000ppm with 'ST-44' smart transmitter and GEN2 smart sensor. Includes Color TFT Display, 4-20mA output. OPTIONAL two RS-485 Modbus ports, embedded Ethernet with Webserver, Modbus TCP, 2 Alarm + Fault Relays. 10-30 VDC. Aluminum, Stainless Steel or Poly enclosure. CSA certified for Class 1 Div 1 (Explosion-Proof). IP66.

Configure

$2,389.61 
QTU-QRU-C-111
(6855)

SPECTREX  QTU-QRU-C-111

SPECTREX SafEye Quasar 950 open path gas detector and source with ultraviolet technology to detect toxic Hydrogen Sulfide (H2S) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$29,843.47 
Page: 1 | 2 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.