System Sensor P2r | Horn + Beacon | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

SYSTEM SENSOR   P2R

SYSTEM SENSOR P2R
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
System Sensor P2R 2-Wire Horn Strobe at 88+ dbA. Standard cd (15, 15/75, 30, 75, 95, 110, and 115 candela settings). Plug-in design. Red housing. 12 or 24 VDC Operation. For celling or wall mounting. cUL, FM and MEA Approved.

P2R   
Please Email us your request for quote   

Options
Surface Mount

   2 Weeks  ]

SpectrAlert ® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits.

FEATURES

  • Plug-in design with minimal intrusion into the back box
  • Tamper-resistant construction
  • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela
  • Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185
  • Horn rated at 88+ dBA at 16 volts
  • Rotary switch for horn tone and three volume selections
  • Universal mounting plate for wall units
  • Mounting plate shorting spring checks wiring continuity before device installation
  • Electrically Compatible with legacy SpectrAlert devices
  • Compatible with MDL3 sync module
  • Listed for ceiling or wall mounting
Agency Listings and Approvals

Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status.

  • UL Listed: S4011
  • ULC Listed: S8971
  • FM Approved
  • CSFM: 7135-1653:175
  • MEA Approved: 492-04-E Vol. 2

The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement.

Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults.

To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed.

Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections.

Architect/Engineer Specifications
General

SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 × 4 × 11⁄2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate.

Also, SpectrAlert Advance products, when used with the Sync•Circuit TM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185.

Horn Strobe Combination

The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply.

Synchronization Module

The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply.

Physical/Electrical Specifications
Standard Operating Temperature 32°F to 120°F (0°C to 49°C)
Humidity Range 10 to 93% non-condensing
Strobe Flash Rate 1 flash per second
Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR 1
Operating Voltage Range 8 to 17.5V (12V nominal) or 16 to 33 V (24V nominal)
Operating Voltage Range MDL3 Sync Module 8.5 to 17.5V (12V nominal) or 16.5 to 33V (24V nominal)
Input Terminal Wire Gauge 12 to 18 AWG
Wall-Mount Dimensions (including lens) 5.6 ̋ L × 4.7 ̋ W × 2.5 ̋ D (142 mm L × 119 mm W × 64 mm D)
Horn Dimensions 5.6 ̋ L × 4.7 ̋ W × 1.3 ̋ D (142 mm L × 119 mm W × 33 mm D)
Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7 ̋ L × 4.8 ̋ W × 0.35 ̋ D (145 mm L × 122 mm W × 9 mm D)

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORN + BEACON :    92 Items found.
AL121AXHDC024G/R-UL
(5132)

E2S  AL121AXHDC024G/R-UL

E2S AL121AXH Appello X Recordable Sounder 126dB(A) and High Output LED Beacon (L101H). 24VDC or 230VAC Versions. Stainless steel fixings. IP66. EAC, UL & cULs approved.

HAB121RTHDC012G/R
(3651)

E2S  HAB121RTHDC012G/R

E2S HAB121RTH Electronic Siren, Buzzer, Claxon and Bell 121dB(A). Includes beacon with 40W halogen bulb. Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 12VDC. IP66.

AL121HDC024R/A
(4431)

E2S  AL121HDC024R/A

E2S AL121H Alarm Horn Sounder (A121) 126dB(A) and High Output LED Beacon (L101H). 115VAC. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

AL121XDC024R/R
(3556)

E2S  AL121XDC024R/R

E2S AL121X Alarm Horn Sounder (A121) 126dB(A) and 5 Joule Xenon Strobe Beacon (L101X). 115VAC, 230VAC, 24VAC, 24VDC or 48VDC Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. Optional UL version.

AB121LDADC024G/A
(3604)

E2S  AB121LDADC024G/A

E2S AB121LDA Alarm Sounder 126dB(A) and LED Beacon with 9 user selectable operation modes. Heavy duty sounder. Automatic synchronisation. Stainless Steel fixings. 24VDC, 48VDC, 115 VAC or 230VAC Versions. IP65. VdS Approved.

HAL121XAC115R/A
(5135)

E2S  HAL121XAC115R/A

E2S HAL121X Electronic Siren, Buzzer, Claxon and Bell 121dB(A) and 5 Joule Xenon Beacon. 24VDC, 115VAC or 230VAC Versions. Stainless steel fixings. IP56. GOST-R Approved.

REM-1L-R-FLASH
(5115)

COOL AIR  REM-1L-R-FLASH

Cool Air Indoor/Outdoor Remote Alarm Light & Horn Unit for LBW-50 or LBW-420 Ammonia Leak Detector. Provides a brighter light via a combination of long-life LEDs and a daybright lens. NEMA 4X box, light, horn, 24VDC. Output is 99db at 1 meter.

Configure

$541.20 
HMCA11205DC024G-AM
(3653)

E2S  HMCA11205DC024G-AM

E2S HMCA121-05 Electronic Siren, Buzzer, Claxon and Bell 122dB(A). With 5 Joules Xenon Beacon. Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel guard and fixings. 24VDC or 230VAC Versions. IP66 & IP67. GOST-R approved.

MC1LD2FDC024AN1A1GA
(6826)

E2S  MC1LD2FDC024AN1A1GA

E2S MC1LD2F Alarm Sounder 117dB(A) and LED Beacon with 7 user selectable operation modes. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 24VDC, 115VAC or 230VAC Versions. CE, RMRS Approvals.

MCA112L1DC024G-AM
(3610)

E2S  MCA112L1DC024G-AM

E2S MCA112-L1 Alarm Sounder 119dB(A) and LED Beacon with 9 user selectable operation modes. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 24VDC, 24VAC, 115 VAC or 230VAC Versions. GOST-R Approved. ***phased out, replaced by MC1LD2F ***

HO-REM-HU-ST-24
(3696)

COOL AIR  HO-REM-HU-ST-24

Cool Air High Output Remote Alarm Horn & Strobe Unit for LBW-50 or LBW-420 Ammonia Leak Detector. NEMA 4X box. Max 117 dB(A), No Cable.

Configure

$582.20 
DL105XDC012G/A
(6464)

E2S  DL105XDC012G/A

E2S DL105X 112dB(A) Alarm Sounder & 5 Joule Xenon Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL105HDC024G/A
(6463)

E2S  DL105HDC024G/A

E2S DL105H 112dB(A) Alarm Sounder & 120cd LED Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL112HDC024G/A
(6465)

E2S  DL112HDC024G/A

E2S DL112H 119dB(A) Alarm Sounder & 120cd LED Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

DL112XDC012G/A
(6466)

E2S  DL112XDC012G/A

E2S DL112X 119dB(A) Alarm Sounder & 5 Joule Xenon Beacon. Low current consumption and high SPL. IP66 enclosure. 2 M20 entries. UL and cULs approvals.

MC1X05FDC024CN1A1G/Y
(6925)

E2S  MC1X05FDC024CN1A1G/Y

E2S MC1X05F Alarm Sounder 117dB(A) and 5J Xenon Beacon with 1Hz flash rate. High output sounder with a robust, fire retardant, IP66 & IP67 housing. Suitable for harsh environments. Stainless Steel fixings and guard. 12VDC, 24VDC, 48VDC, 115 VAC or 230VAC Versions. GOST-R Approved.

E2XC1LD2FAC115CN1A1B/A
(6421)

E2S  E2XC1LD2FAC115CN1A1B/A

E2S E2xC1LD2F Combination Alarm Horn & LED Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1X05RAC115CN1A1B/A
(6420)

E2S  E2XC1X05RAC115CN1A1B/A

E2S E2xC1X05R Combination Radial Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 114dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1X05FAC115CN1A1B/A
(6419)

E2S  E2XC1X05FAC115CN1A1B/A

E2S E2xC1X05F Combination Alarm Horn & 5 Joule Xenon Beacon for hazardous locations. Up to 116dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

E2XC1LD2RAC115CN1A1B/A
(6422)

E2S  E2XC1LD2RAC115CN1A1B/A

E2S E2xC1LD2R Combination Radial Horn & LED Beacon for hazardous locations. Up to 114dB(A). Dual M20x1.5 or 1/2"NPT entries. IP66. UL approved for Class I/II Div 2, Class I Zone 2/Zone 22. IECEx and ATEX certified.

Page: 1 | 2 | 3 | 4 | 5 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.