HONEYWELL   SPXCDULNH2

HONEYWELL SPXCDULNH2
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Honeywell Sensepoint XCD RTD Gas Detector for Hydrogen Sulfide (H2S) with Electrochemical Sensor. Aluminium alloy LM25 or 316 stainless steel housing, PPS sensor head, tri-color backlit LCD Display. IP67. 3-wire 24 VDC power. Includes 3 programmable alarm relays and 4-20mA output (sink or source selectable), Modbus RTU option available. User-Selectable full scale range 0 to 50 ppm. UL/cCSAus Approved for Class I Div 2. Remote Sensor Option.

SPXCDULNH2   
1,735.82

Modbus RTU
Enclosure
Agency Approval
Remote Sensor
Juntion Box
Entry
Sunshade/Deluge Protection
Custom Tag

 15 Weeks  ]
32 Variants of base SKU / 30 Shown below

Sensepoint XCD RTD from Honeywell Analytics makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I, Div 2 areas.

You can mount the unit up to 100 feet from the transmitter to obtain maximum gas detection coverage in areas not easily accessible or where the sensor would not be visible, as in high-or low-level concealed areas, or detection outside the room being monitored. XCD RTD offers unrivaled flexibility and performance via its easily recognizable display (traffic light pattern) to convey safety status, communication and mounting options, and onboard diagnostics.

Applications
  • Waste water facilities
  • Utilities
  • Coal processing plants
  • Industrial manufacturing facilities
  • Power plants
  • Food and beverage production
  • Oil and gas process areas
Reduce Cost of Ownership Over Life of the Product
  • CHONEYWELL, SENSEPOINT, XCD RTD, GAS DETECTOR, HYDROGEN, H2, REMOTE ELECTROCHEMICAL SENSOR, ALUMINIUM, STAINLESS STEEL, PPS, IP67, RELAYSut stocking and procurement costs with a common transmitter platform
  • Reduce maintenance time and expense with non-intrusive, one-man operation
  • Simplify maintenance with plug-in, removable sensor
  • Reduce inspection and training time with tri-color ‘traffic light’ display conveying safety status at a glance
  • Simplify set-up and configuration with non-intrusive magnetic switches
Gain Added Flexibility, Reliability and Performance
  • Extend gas sensing element up to 100 feet (30 meters) from transmitter; mount in the most difficult to access areas
  • Reduce likelihood of human error via on-board diagnostics and easy-to-read display
  • Protect against dust/water ingress with IP66/67 rated stainless steel or aluminum enclosure
  • Prevent false alarms with auto-inhibit during maintenance
  • Select sink or source 4-20mA output; integral or remote configuration
  • Full range of accessories and purchase options let you choose the remote monitoring system that’s right for your application
Safety at a Glance!

Sensepoint XCD uses three instantly recognizable ‘traffic light’ colors to indicate its status. The large tri-color backlit LCD is steady green to indicate normal operation, flashes yellow to indicate a fault/warning and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.

XCD normal display (green) XCD Display in Fault/Warning (Yellow) XCD display in Alarm (Red)
Normal Fault/Warning Alarm
Get More Return on Investment from the Practical Advantages of XCD RTD

Sensepoint toxic and oxygen sensors detect a wide variety of industrial gases at common measuring ranges, adding flexibility to your gas monitoring program, reducing your parts procurement costs and expanding your safety net.

Remote gas monitoring has never been this easy and cost-effective. Mount the sensor as shown in the illustration and view gas safety status via the large tri-color display on the transmitter, up to 100 feet away from the sensor. The advantages of this remote monitoring system are added safety, and reduced time spent on maintenance. There’s no need for your team to climb ladders or bring in specialized equipment to view gas concentration readings or to conduct a safety audit. What’s more, the removable sensor design of Sensepoint XCD RTD cuts downtime and eliminates the need for specialized training.

Specifications
Gas Hydrogen Sulfide (H2S)
Sensor Type Toxic
User Selectable Full Scale Range 50.0ppm
Range Increments N/A
Class I, Division 2 Yes
Lower Alarm 10.0ppm
Lower Alarm Type Rising
Higher Alarm 20.0ppm
Higher Alarm Type Rising
Lowest Alarm Level 5.0ppm

General Transmitter Specifications
Use 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from toxic and oxygen hazards.
Incorporating a transmitter with local display and optional remote mounted sensor, fully configurable via non-intrusive magnetic switch interface with a wide range integral and remote sensors available.
Electrical
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Maximum power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W
Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable)
Alarm relays default normally open/de-energized. Fault relay default normally open/energized
Communication RS485
Construction
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: Polyphenylene sulfide (PPS) (see Sensepoint specifications)
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
Cable Entries 2 x 3⁄4”NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating
Environmental
IP Rating IP67 in accordance with EN60529:1992

Certification
US, Latin America, Canada cCSAus Ex d IIB+H2; Class I, Zone 1, AEx d IIB+H2; Class I, Division 2, Groups B, C & D
Class I, Zone 1, AEx d ia IIC Gb; Class I, Div. 2, Groups B, C and D
Inmetro Ex d IIC T6 Gb, Ex tb IIIC T85oC Db, IP66, -40oC < ta < +65oC
EMC CE: EN50270:2006 EN6100-6-4:2007, Ex d IIC T6 Gb, Ex tb IIIC T85oC Db, IP66, -40oC < ta < +65o C
Standards CAN/CSA-C22.2 No. 0-M91, CAN/CSA-C22.2 No. 60079-0:07, CAN/CSA-E60079-11:02, CAN/CSA-C22.2 No. 60079-1:07, ANSI/UL 60079-11:09, ANSI/UL 60079-1:09, C22.2 No. 142-M1987, C22.2 No. 213-M1987, UL 508 17th Ed., ANSI/ISA -12.12.01-2010 ABNT NBR IEC 60079-0:2008, ABNT NBR IEC 60079-1:2009, IEC 60079-31:2008 e ABNTNBR IEC 60529:2009.
Export Info
Made inSouth Korea
Harmonized Tariff Code (HTC)9027102000

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESSORIES - RELATED - CONSUMABLES :    15 Items found.
SPXCDMTBR
(670)

HONEYWELL  SPXCDMTBR

Mounting bracket for Honeywell Sensepoint XCD Sensors. Includes bolts, nuts and brackets



$104.72 
(668)

HONEYWELL  SPXCDCC

Collecting cone for use with lighter than air gases for Honeywell Sensepoint XCD Sensors.



$119.23 
02000-A-1645
(1879)

HONEYWELL  02000-A-1645

Calibration Gas Flow Adaptor/calibration cup for use with Honeywell XCD RTD Sensepoint sensors.



$146.19 
CYL-10338750
(1743)

PORTAGAS  CYL-10338750

Calibration Gas Hydrogen Sulfide (H2S) 500 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-10338000
(1292)

PORTAGAS  CYL-10338000

Calibration Gas Hydrogen Sulfide (H2S) 100 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-10326000
(1290)

PORTAGAS  CYL-10326000

Calibration Gas Hydrogen Sulfide (H2S) 20 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-10332000
(683)

PORTAGAS  CYL-10332000

Calibration Gas Hydrogen Sulfide (H2S) 50 ppm Balance Nitrogen, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-90099192
(311)

PORTAGAS  CYL-90099192

Calibration Gas Hydrogen Sulfide (H2S) 300 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminium Cylinder. (Made by Portagas)

Configure

$171.58 
CYL-10321000
(310)

PORTAGAS  CYL-10321000

Calibration Gas Hydrogen Sulfide (H2S) 10 ppm Balance Air, 58 Liter GAL C-10 Inlet Portagreen Aluminum Cylinder. (Made by Portagas)

Configure

$171.58 
SPXCDSDP
(671)

HONEYWELL  SPXCDSDP

Sunshade/Deluge Protection for Honeywell Sensepoint XCD Sensors.



$402.28 
(1912)

HONEYWELL  2106B2114

Signalpoint XCD RTD Toxic/Oxygen Calibration Kit w/calibration cover, removal tool and potentiometer adjustment tool for Honeywell Sensepoint Sensors. (*2106B2114 requires 02000-A-1645 flow housing-sold separately) *** Phased Out ***



$419.90 
SPXCDDMK
(669)

HONEYWELL  SPXCDDMK

Duct mounting kit for Honeywell Sensepoint XCD Sensors.



$443.75 
(1917)

HONEYWELL  2106B1549

Honeywell Sensepoint Replacement Electrochemical Cell Exchange Kit for Hydrogen sulfide (H2S) 0-50 ppm . Includes sensor cartridge, RFI screen, hydrophobic barrier, and o-ring.



$826.33 
2106B1801
(5103)

HONEYWELL  2106B1801

Honeywell Sensepoint XCD RTD Replacement Electrochemical Sensor assembly for Hydrogen Sulfide (H2S) 0-50 ppm



$1,269.69 
TPPLBDWA2NNNNNN
(5825)

HONEYWELL  TPPLBDWA2NNNNNN

Honeywell Touchpoint Plus Wall-mounted Alarm Controller for up to 8 gas detection channels (16 w/ expansion unit). Dustproof and waterproof. Polycarbonate ABS Housing (NEMA 4X). Includes touchscreen interface, built-in sounder, 3 alarm relay outputs, datalogging to SD card and remote reset and inhibit inputs. AC or DC supply voltage. Up to 24 relay outputs and 8mA outputs. IP65. UL and CSA approvals (Class I Div 2).

> HYDROGEN SULFIDE :    38 Items found.