E2s E2xs2fdc024cn1a1b | Horns | Class I Div 2 And Class Ii Div 2 | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   E2XS2FDC024CN1A1B

E2S E2XS2FDC024CN1A1B
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S E2xS2F 121dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.

E2XS2FDC024CN1A1B   
Please Email us your request for quote   

Voltage
Cable Entries
Bracket
Metric Adaptor

   2 Weeks  ]
48 Variants of base SKU / 30 Shown below

The hazardous area E2xS2F alarm horn sounder is UL/cULs approved for Class I Div 2 and Class II Div 2 as well as IECEx and ATEX certified for Zone 2 and 22 applications.

With a maximum sound level output of 121dB(A) at 1 metre and a choice of 45 alarm tones and 3 remotely selectable stages the E2xS2F alarm so under horn is suitable for all signalling applications with high ambient noise levels.

The E2x range features enclo sures manufactured from lightweight, corrosion proof PPS and high impact, fire retardant ABS re-entrant flare horns; both of which are suitable for the harshest of environments.

Features:
  • Automatic synchronisation on multi-sounder system.
  • Continuously rated.
  • Large termination area.
  • Stainless steel fixings.
  • Ratchet adjustable stainless steel ‘U’ bracket for 360° positioning.
  • Duplicate cable terminations (in & out for daisy-chain installations).
  • Tropicalisation available on request.
  • Available with custom tone configurations and frequencies.
Approvals:

  • ATEX certificate: DEMKO 06 ATEX 0421554X
  • IECEx certficate: IECEx ULD 14.0012X
  • UL/cUL File ref: E230764
Coding
  • IECEx / ATEX:
    II 3G Ex nA IIC T4 Gc Ta -20°C to +55°C
    II 3D Ex tc IIIC T85°C Dc Ta -20°C to +55°C
  • NEC Class / Zone ratings US:
    Class I Zone 2 AEx nA IIC T4 Gc Ta -20°C to +55°C
    Zone 22 AEx tc IIIC T85°C Dc Ta -20°C to +55°C
  • CEC Class / Zone ratings Canada
    Ex nA IIC T2 Gc Ta -20°C to +55°C
    Ex tc IIIC 85°C Dc Ta -20°C to +55°C
  • NEC & CEC Class / Division Ratings for US / Canada
    Class I, Div 2, ABCD T3C Ta -20°C to +55°C
    Class I, Div 2, ABCD T4 Ta -20°C to +40°C
    Class II, Div 2, FG T6 Ta -20°C to +55°C
    Class II, Div 2, FG T6 Ta -20°C to +55°C

Specification
Maximum output: 121dB(A) @ 1 metre [112dB(A) @ 10ft/3m]
Nominal output: 117dB(A) @ 1m +/- 3dB – Tone 2 [108dB(A) @ 10ft/3m]
No. of tones: 45 (UKOOA / PFEER compliant)
No. of stages: 3
Volume control: Max. 117dB(A); Min. 111dB(A) - Tone 2
Effective range: 200m/656ft @ 1KHz
Voltages DC: 24Vdc (10-30Vdc); 48Vdc
Voltages AC: 115Vac; 230Vac
Ingress protection: IP rating per EN60079-0:IP64
IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/13
Enclosure material: UL94V0 PPS & ABS
Cable entries: Dual M20x1.5 or 1/2"NPT
Terminals: 0.5 to 1.5mm2 cables.
Line monitoring: Blocking diode included EOL can be factory fitted
Operating temp: -20 to +55°C [-4° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 2.75kg/6.05Ibs AC: 3.25kg/7.15Ibs
*SPL data +/-3dB(A). Measured at optimum voltage.
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)85318030

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    73 Items found.
DB3BD_G_0481BNNNNN
(4227)

MEDC  DB3BDG0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Exd(e), Weatherproof. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C. ATEX Certified, Ex d. CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,268.26 
DB3BULG_0481BNNNNN
(4229)

MEDC  DB3BULG0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Exd(e), Weatherproof. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C. UL Hazardous & Ordinary Locations certified for Class I, Division 1. Groups A-D.

Configure

$1,268.26 
BEXDS120E_12DC
(3660)

E2S  BEXDS120E12DC

E2S BExDS120E flameproof Alarm Horn Sounder 123dB(A). LM6 aluminium enclosure. 32 alarm tones and 3 remotely selectable stages. Suitable for Zone 1, 2, 21 & 22 applications. Two M20 cable entries. IP66. ATEX, IECEx, GOST-R (2ExdeIICT4), VdS, CPD, SIL1 and Inmetro Approved.

GNEXS1DC024AB1A1R
(6440)

E2S  GNEXS1DC024AB1A1R

E2S GNExS1 flameproof 117dB(A) Alarm Horn Sounder. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

GNEXS1RDC024AB1A1R
(6441)

E2S  GNEXS1RDC024AB1A1R

E2S GNExS1-R flameproof 115dB(A) Radial Alarm Horn Sounder with Omni-directional sound output. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

GNEXS2DC024AB1A1R
(6442)

E2S  GNEXS2DC024AB1A1R

E2S GNExS2 flameproof 123dB(A) Alarm Horn Sounder. 64 alarm tones and 4 selectable stages. Dual M20 entries. IP66/67. Suitable for Zone 1 & 2. ATEX and IECEx approvals.

DB3_VE_NNN1B_N
(4180)

MEDC  DB3VENNN1BN

MEDC DB3V Sounder (up to 110 dB(A)), Zone 1, Zone 2 and non-Ex use, Exd(e), Weatherproof, IP66 and IP67, intended for use in potentially explosive gas and dust atmospheres. -55C to +70C. ATEX approved Ex II 2GD, EExde IIC T5. CUTR and Inmetro certifications also available.

DB3BD_E_0481BNNNNN
(4228)

MEDC  DB3BDE0481BNNNNN

MEDC DB3B Sounder (up to 125dB(A)) with 28 output tones. Exd(e), Weatherproof. IP66 & IP67. NEMA 4X & 6. Designed to be used on potentially explosive gas and dust atmospheres. -55C to +70C. ATEX Certified, Ex de. CUTR, IECEx, Inmetro and CQST versions also available.

DB3_VD_NNN1B_N
(1608)

MEDC  DB3VDNNN1BN

MEDC DB3V Sounder (up to 110 dB(A)), Zone 1, Zone 2 and non-Ex use, Exd(e), Weatherproof, IP66 and IP67, intended for use in potentially explosive gas and dust atmospheres. -55C to +70C. ATEX Certified Ex II 2GD, Ex d IIC T4/T5 Gb, Ex tb IIIC T100°C/T135°C Db. CUTR, Inmetro and CQST certifications also available.

STEXS1FDC024AS2A1R
(5143)

E2S  STEXS1FDC024AS2A1R

E2S STExS1F 117dB(A) Alarm Horn Sounder with re-entrant flare horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

STEXS1RDC024AS2A1R
(6458)

E2S  STEXS1RDC024AS2A1R

E2S STExS1R 115dB(A) Alarm Horn Sounder with omni-directional horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

STEXS2FDC024AS2A1R
(6459)

E2S  STEXS2FDC024AS2A1R

E2S STExS2F 123dB(A) Alarm Horn Sounder with re-entrant flare horn. IP66 corrosion proof 316L stainless steel enclosure. 64 channel alarm sounds. 3 cable entries. Remotely triggering. Suitable for All Zone 1, 2, 21 & 22. IECEx and ATEX Approved.

A141DC024G
(3637)

E2S  A141DC024G

E2S A141 High Level Audible Warning System 141dB(A). High output. Ideal for wide area and disaster warning applications. 4 100W drivers. 24VDC or 230VAC Versions. IP65. GOST-R Approved.