Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
MACURCO:    82 Items found.
(3616)

MACURCO  CM-E1 Harness

MACURCO CM-E1 Wire Harness with White Plug for CM-E1 Gas Detectors.



$6.85 
(2990)

MACURCO  CM-E1-FTG

Macurco CME1-FTG Carbon Monoxide (CO) 500 ppm field test gas to test Macurco fixed gas detectors (CM-6 and CM-E1). 11L, Aerosol, 1/cs.

Configure

$83.42 
(2992)

MACURCO  CME1-FTK

Macurco CME1-FTK Carbon Monoxide (CO) 200 ppm gas field test kit to test or calibrate Macurco fixed gas detectors (CM-E1 and CM-6). 17L. Includes Carry Case, Regulator, Tubing and CM-E1 test hood. 1/cs. *** Discontinued ***



 
(3617)

MACURCO  CM-E1-IAK

MACURCO CM-E1-IAK Installation Adapter Kit used to retrofit Macurco-2 gang type installations (CM-15, CM-15A, CM-16A, etc) to CM-E1 single gang detectors.



$19.38 
(3618)

MACURCO  CM-E1-IAK/10

MACURCO CM-E1-IAK Installation Adapter Kit (10 Pack) used to retrofit Macurco-2 gang type installations (CM-15, CM-15A, CM-16A, etc) to CM-E1 single gang detectors.



$133.98 
(644)

MACURCO  CME-FCK

Macurco CME-FCK carbon monoxide field calibration kit is used to test or calibrate Macurco fixed gas detectors requiring two point calibration (CM-3 and CS102A) or single point calibration (CM-4, CM-2B, CM-21A, CM-1B and SS102HC). ****** DISCONTINUED****



 
(645)

MACURCO  CMS-FCK

Macurco CMS-FCK carbon monoxide field calibration kit is used to test or calibrate Macurco fixed gas detectors requiring single point calibration (CM-4, CM-2B, CM-21A, CM-1B and SS102HC) . Includes 17-liter 50 PPM CO, regulator, tubing and case. ***** REPLACED BY CM6-FCK *****



 
(3621)

MACURCO  CO200PPM

MACURCO CANN200PPM Carbon Monoxide (CO) Calibration Gas. 17L. 200 ppm. Balance Air.



$98.63 
(3620)

MACURCO  CO50PPM

MACURCO CANN50PPM Carbon Monoxide (CO) Calibration Gas. 17L. 50 ppm. Balance Air.



$98.63 
(639)

MACURCO  CS102A

Macurco CS102A carbon monoxide transducer features an electrochemical sensor, status LED, 12-24 VAC or VDC operation and 1-3VDC output (0-250ppm). For use with the MACURCO SS103 Controllers and HVAC/Building Automation Systems *********** DISCONTINUED ********* Replaced by CM-6



 
(2117)

MACURCO  CX/TX-CH

MACURCO Calibration Hood/cup for CX, TX, OX, & RD series gas detectors: ammonia (NH3), hydrogen sulfide (H2S) and Nitrogen Dioxide (NO2).



$33.38 
(6822)

MACURCO  CX-6

Macurco CX-6/CX-12 Fixed Gas Detector for low level detection of Carbon Monoxide (CO) 0-200ppm and Nitrogen Dioxide (NO2) 0-20 ppm. 4-20 mA output, 5A Fan Relay and 0.5A Alarm Relay. 12 to 24 VAC, 12 to 32 VDC or 100-240 VAC power. LED Display. ETL Listed.

Configure

$859.89 
(643)

MACURCO  DMK-1

Macurco DMK-1 Duct Mount Kit provides a means to duct mount standard 4 x 4 Macurco fixed gas detectors (single gang type need mud-ring). The DMK-1 features an air tight enclosure, clear cover that allows view of detector status lights, hardware, exhaust tube and mounting template. Compatible with CM-6, GD-2A, GD-6, TX-6, CM-2B, CM-3, CM-4, HD-11, ND-2 and GT-11A gas detectors.



$188.12 
(640)

MACURCO  DVP-120

Macurco DVP-120 control panel features 12 sensor inputs, three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,302.82 
(6823)

MACURCO  DVP-1200

Macurco DVP-1200 control panel for up to 192 addressable detectors. Includes 4 Relays (Up to 12), 3 4-20mA analog outputs, 4 24VDC drivers, 3 RS-485 channels and BACnet IP server output. NEMA4X enclosure. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. ETL Listed to UL 2017

Configure

$2,764.23 
(6227)

MACURCO  DVP-120B

Macurco DVP-120B Addressable Detection and Ventilation Panel with BACnet MS/TP output. Modbus-Enabled with up to 87 Modbus RS-485 addressable sensors on two channels and 12 4-20mA sensor inputs (for a total of 99 channels) , three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,752.43 
(3973)

MACURCO  DVP-120M

Macurco DVP-120M Addressable Detection and Ventilation Panel. Modbus-Enabled with up to 87 Modbus RS-485 addressable sensors on three channels of 29 sensors per channel. Features 12 4-20mA sensor inputs (for a total of 99 channels) , three 10 amp output relays, horn and strobe drivers, Internal 90 dbA buzzer, NEMA1 enclosure, and status LEDs. Compatible with MACURCO fixed gas transducers CM-6, GD-6, TX-6, OX-6, CM-2B, CM-3, CM-4, ND-2 and GT-11A over 4-20mA current loops. 90 – 250 VAC. Multi-Channel controller and alarm center for natural gas, methane, propane, hydrogen, carbon monoxide, ammonia, nitrogen dioxide and hydrogen sulfide. Optional LADBS approval.

Configure

$1,444.88 
(7194)

MACURCO  GBC-24-2

Macurco Gas Boiler 2-Channel Emergency Shutdown Controller to Interlock/Shutdown up to 8 boilers in the presence of different gases. Includes up to 8 SPDT Interlock/Emergency Shutdown Relays, green power light, a red alarm light, a boiler reset button and an audible buzzer. 24V or 120V. NEMA 4X (IP66) Enclosure. Compatible with Macurco GD-6, CM-6, TX-6-XX, CD-6, CX-6, OX-6 (24VDC with alarm relay) gas detectors.

Configure

$748.13 
(3416)

MACURCO  GD-12

MACURCO GD-12 line voltage Gas Detector, controller and transducer for Combustibles (EX) 0-50% LEL. Accepts Methane (NG-Natural Gas), Propane (LP-Liquid Propane) or Hydrogen (H2) detection. Selectable 4-20mA output, buzzer, alarm and fan relays with digital display. 100 to 240 VAC 50-60Hz power. ETL Listed to UL 61010-1, CSA Approved.

Configure

$494.01 
(650)

MACURCO  GD-2A

MACURCO Combustible Gas Detector low voltage all-electronic monitor engineered to detect heating type gases, including methane (natural gas) and propane(bottled gas). 12-24 VAC or VDC input. SPDT alarm and NC trouble relays. Listed to UL Standard 2075. CSFM Approved.



$117.91 
Page: 1 | 2 | 3 | 4 | 5 | All


Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.