The NOTIFIER FSV-951R VIEW is high-sensitivity photoelectric
smoke detectors designed for Very Early Warning Fire Detection
and will protect valuable assets and operations where systems must
remain functioning at all times.
FSV-951R VIEW detector features a smoke-sensing chamber and
patented optic block designed to amplify signals from smoke, but
diminish stray internal reflections that can cause false alarms. New
LED technology allows this detector to achieve sensitivity levels from
0.02 percent-per-foot to 2 percent-per-foot obscuration – up to 25
times greater than a standard photoelectric detector. The extensive
software processing includes multi-alert drift compensation, internal
self-diagnostics, and superior transient signal rejection algorithms to
produce unprecedented stability at ultra-high sensitivities across the
full temperature range. This system provides point identification of
the fire location through addressability and offers complete supervi-
sion of both the wiring and detector.
FSV-951R VIEW detector features a smoke-sensing chamber and
patented optic block designed to amplify signals from smoke, but
diminish stray internal reflections that can cause false alarms. New
LED technology allows this detector to achieve sensitivity levels from
0.02 percent-per-foot to 2 percent-per-foot obscuration – up to 25
times greater than a standard photoelectric detector. The extensive
software processing includes multi-alert drift compensation, internal
self-diagnostics, and superior transient signal rejection algorithms to
produce unprecedented stability at ultra-high sensitivities across the
full temperature range. This system provides point identification of
the fire location through addressability and offers complete supervi-
sion of both the wiring and detector.
FlashScan® (U.S. Patent 5,539,389) is a communication pro-
tocol developed by Notifier for high speed communication
between analog intelligent devices. Intelligent devices commu-
nicate in a grouped fashion. If one of the devices within the
group has new information, the panel CPU stops the group poll
and concentrates on single points. The net effect is response
speed greater than five times that of other protocols.
Using the enhanced intelligent sensing algorithms, the intelli-
gent sensing system provides drift compensation (meeting UL
requirements as a calibrated sensitivity meter), maintenance
alert (3 levels), selection of 9 alarm levels and 9 pre-alarm lev-
els, and report of drift compensation used and recent peak val-
ues. The system includes a self-learn sensitivity adjustment to
set the pre-alarm level just above the peak levels sensed over
long periods of time for each detector’s actual environment.
The system includes multi-detector algorithms that permit one
sensor to consider readings from adjacent sensors to provide
faster detection of fires.
- UL 268 listed for Open Air Protection (0.5%/ft. to 2.0%/ft. obscuration)
- UL 268 listed for Special Applications (0.02%/ft. to 0.5%/ft. obscuration)
- UL 268A listed for Duct Applications allowing both in duct and within System Sensor models DNR and DNRW duct smoke detectors
In addition, the new modern profile blends seamlessly with other 900
series detectors, which offer expanded color options to meet con-
temporary aesthetic demands.
VIEW is the ideal detection solution for sensitive environments that
cannot tolerate even small amounts of smoke:
- Telecommunications switching facilities
- Cellular telephone infrastructure
- Integrated circuit fabrication facilities
- Computer rooms
- Traffic control centers
- Data Centers
Features
- Superior EMI protection
- Very Early Warning Fire Detection capability
- Analog communications
- Low standby current
- Rotary address switches
- 360° visibility of device status with dual LEDs
- On-board drift compensation
- Transient rejection algorithms
- Microprocessor design
- FlashScan® or CLIP protocol communications
- New modern profile with expanded color options