E2s Ha121dc024r | Horns | Weatherproof | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

E2S   HA121DC024R

E2S HA121DC024R
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
E2S HA121 Electronic Siren, Buzzer, Claxon and Bell 121dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66. GOST-R approved.

HA121DC024R   
Please Email us your request for quote   

Voltage
Housing Color
Metric Adaptor

   2 Weeks  ]
6 Variants of base SKU

Applications and users that have traditionally demanded conventional electromechanical claxons, sirens, buzzers and bells can now choose the next generation alternative.

The technology employed in the Hootronic range features the latest in amplifier and digital to analogue conversion technology. The E2S Hootronic series of products faithfully reproduce the sounds made by legacy electro-mechanical signalling devices but in a modern, reliable and cost effective way.

With output levels of up to 121dB(A) at 1 metre the HA121 surpasses legacy electro-mechanical devices in performance and effectiveness, it is also continuously rated, requires zero maintenance and the signal quality will not degrade with age.

Features:

The products in the Hootronic range have 5 user selectable ‘traditional’ sounds including:

  • Tone 1 : Industrial Claxon
  • Tone 2 : High Frequency Mechanical Siren
  • Tone 3 : Medium Frequency Mechanical Siren
  • Tone 4 : Electro Mechanical Buzzer
  • Tone 5 : Mechanical Bell

Each of these sounds have two additional, remotely selectable, alarm stages.

Remote switch generates genuine ‘tail off’ to sound when alarm is terminated.

  • Automatic synchronisation on multi-sounder system.
  • Continuously rated.
  • Stainless steel fixings.
  • Unit can be mounted using external lugs or internal BESA compatible fixing positions.
  • Duplicate cable terminations (in & out for daisy-chain installations).
  • Tropicalisation available on request.
Approvals:

  • GOST-R approved. Cert: POCC GB.JB05.H00144.

Specification
Maximum output: 12 1dB(A) @ 1m +/- 3dB - Tone 2 [112 dB(A) @10ft/3m]
No. of tones: 5
No. of stages: 3
Volume control: Max. 12 1dB(A);
Min. 112 dB(A) approx.
Effective range: 300m/984ft @ 1KHz
Voltages DC: 24V dc (10-30V dc);
Voltages AC: 115 Vac; 230V ac
Ingress protection: IP66
Housing material: High impact UL94 V0 & 5VA FR ABS
Colour: Red (RAL3000) & grey (RAL7038)
Cable entries: 2 x M20 clearance gland knockouts in side & back
Terminals: 0.5 to 4.0mm2 cables.
Operating temp: -25 to +55°C [-13° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 2 .10kg/4.62 Ibs AC:2 .70kg/5.94Ibs
Export Info
Made inUnited Kingdom
Harmonized Tariff Code (HTC)85318030

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> HORNS :    73 Items found.
IS-PA1-G
(3692)

E2S  IS-PA1-G

E2S IS-pA1 compact Panel Mount Sounder 90dB(A). 16-28VDC. Produces a high frequency continuous tone. Ideal for control panels. IP66. ATEX, IECEx and GOST-R approved.



 
HA105NDC024G
(3654)

E2S  HA105NDC024G

E2S HA105N Electronic Siren, Buzzer, Claxon and Bell 112dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC or 230VAC Versions. IP66. GOST-R approved.

MA112DC024G
(3606)

E2S  MA112DC024G

E2S MA112 Alarm Horn Sounder 119dB(A). High output. With robust and fire retardant IP66 & IP67 housing. Suitable for harsh environments. Automatic synchronisation and Stainless Steel fixings. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. GOST-R Approved.

D105DC024R
(5126)

E2S  D105DC024R

E2S D105 high output, 112dB(A) Alarm Sounder. Low current consumption and high SPL. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. Marine grade aluminium housing. Stainless steel fixings. Programmable version available. IP66. UL & cULs approved.

A121DC_24R
(3277)

E2S  A121DC24R

E2S A121 very high output Alarm Sounder 126dB(A). High SPL. 24VAC, 115VAC, 230VAC, 24V or 48V Versions. Stainless steel fixings. Programmable version available. IP66. VdS and GOST-R Approved. UL version available.

A121AXDC024R-UL
(3281)

E2S  A121AXDC024R-UL

E2S A121AX Appello X User Recordable Alarm Sounder 112dB(A). Low current consumption. 10-30VDC or 90-250VAC Versions. Robust fire retardant Type 4/4X/3R/13, IP66 housing. UL approved.

MA121DC024G
(3607)

E2S  MA121DC024G

E2S MA121 Alarm Horn Sounder 126dB(A). Very high output. With robust and fire retardant IP66 & IP67 housing. Suitable for harsh environments. Automatic synchronisation and Stainless Steel fixings. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. GOST-R Approved.

HMA121DC024G
(3652)

E2S  HMA121DC024G

E2S HMA121 Electronic Siren, Buzzer, Claxon and Bell 124dB(A). Reproduces the sounds made by legacy electro-mechanical signalling devices in a modern, reliable and cost effective way. Stainless steel fixings. 24VDC, 115VAC or 230VAC Versions. IP66 & IP67. GOST-R approved.

D112DC024R
(5127)

E2S  D112DC024R

E2S D112 high output, 119dB(A) Alarm Sounder. Low current consumption and high SPL. 24VDC, 48VDC, 24VAC, 115VAC or 230VAC Versions. Marine grade aluminium housing. Stainless steel fixings. Programmable version available. IP66. VdS, UL & cULs approved.

IS-D105-G
(6425)

E2S  IS-D105-G

E2S IS-D105 105dB(A) intrinsically safe Alarm Sounder. 49 alarm tones and 2 remotely selectable stages. 2 M20 entries. 24VDC. IP66. ATEX and IECEx approvals.

E2xS112FDC024A1A1B
(4423)

E2S  E2xS112FDC024A1A1B

E2S E2xS112 Alarm Sounder/Horn 116dB(A). Suitable for all general signalling duties in the harshest of environments. PPS & ABS high impact housing. 24VDC, 115VAC or 230VAC Versions. UL/cULs Approved for Class I Div 2 and Class II Div 2. ATEX and IECEx Approved.

DB5_B024NR
(1569)

MEDC  DB5B024NR

MEDC DB5 Sounder (up to 103 dB(A)) with 26 output tones, Zone 0, Zone 1, and Zone 2 use, Intrinsically Safe (Exia), Weatherproof, IP65, designed with a high weatherproof rating to cope with the harsh environmental condition. -20C to +55C. ATEX, IECEx and CCC approvals also available.

Configure

$532.94 
MV121DC024G-UL
(3608)

E2S  MV121DC024G-UL

E2S MV121 Appello X User Recordable Alarm Sounder 126dB(A). Low current consumption. With robust and fire retardant IP66 & IP67 housing. Volume Control. 14-30VDC or 90-260VAC Versions. UL and cULs Approved.

E2XS121FDC024A1A1B
(4424)

E2S  E2XS121FDC024A1A1B

E2S E2xS121 Alarm Sounder/Horn 121dB(A). Suitable for all general signalling duties in the harshest of environments. PPS & ABS high impact housing. 24VDC. UL/cULs Approved for Class I Div 2 and Class II Div 2. ATEX and IECEx Approved.

D2XS1AC115CN1A1G
(4426)

E2S  D2XS1AC115CN1A1G

E2S D2xS1 Alarm Horn Sounder 116dB(A). Low current consumption and high SPL. Type 4/4X, IP66 enclosure. Suitable for all haz loc applications. 4 remotely selectable alarm stages. 64 alarm tone frequencies. UL approved for Class I Div 2 and Class II Div 2. IECEx and ATEX Approved.

DB7PW012NR
(4186)

MEDC  DB7PW012NR

MEDC DB7 Sounder (up to 110 dB(A)) with 27 output tones, Weatherproof only version, IP66 and IP67, intended for use in potentially explosive atmospheres. -55C to + 70C.

Configure

$620.93 
E2XS1FDC024CN1A1B
(6423)

E2S  E2XS1FDC024CN1A1B

E2S E2xS1F 116dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.

DB7PBB012NR
(1610)

MEDC  DB7PBB012NR

MEDC DB7 Sounder (up to 110 dB(A)) with 27 output tones, Zone 0, Zone 1, and Zone 2 use, Intrinsically Safe (Exia), Weatherproof, IP66 and IP67, intended for use in potentially explosive atmospheres. -55C to + 70C. ATEX Approved Ex II 1G, BASEEFA Certified, EExia IIB T4. CUTR version also available.

Configure

$689.04 
DB7PBC012NR
(4185)

MEDC  DB7PBC012NR

MEDC DB7 Sounder (up to 110 dB(A)) with 27 output tones, Zone 0, Zone 1, and Zone 2 use, Intrinsically Safe (Exia), Weatherproof, IP66 and IP67, intended for use in potentially explosive atmospheres. -55C to + 70C. ATEX Approved Ex II 1G, BASEEFA Certified, EExia IIC T4. CUTR version also available.

Configure

$752.76 
E2XS2FDC024CN1A1B
(6424)

E2S  E2XS2FDC024CN1A1B

E2S E2xS2F 121dB(A) Alarm Sounder for hazardous locations. 45 alarm tones and 3 remotely selectable stages. Dual M20x1.5 or 1/2"NPT entries. IP66. UL/cULs approved for Class I/II Div 2 and Class I Zone 2/22. ATEX and IECEx approvals.