Tyco 4099-9004 | Call Points | Indoor | Gasdetectorsusa
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas

TYCO   4099-9004

TYCO 4099-9004

ALARM SIGNAL DEVICES / INDOOR
CALL POINTS

$67.52  [2 Days]
  • DESCRIPTION
  • FEATURES
  • SPECIFICATIONS
  • LITERATURE
Tyco Simplex 4099-9004 addressable manual station with communication module for IDNet or MAPNET II. LED indicator. Breakglass or push operation. Surface or Flush mounting. NEMA 1. Complies with ADA requirements. UL listed.

4099-9004   
67.52

Version

   2 Days  ]

Standard configurations typically available in 2 Days:
4099-9004__    4099-9006__
11 Variants of base SKU
Features Individually addressable manual fire alarm stations with:
  • Power and data supplied by IDNet or MAPNET II addressable communications using a single wire pair
  • Operation that complies with ADA requirements
  • Visible LED indicator that flashes during communications and is on steady when the station has been activated
  • The NO GRIP Single Action Station and Retrofit Kit are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate
  • Pull lever that protrudes when alarmed
  • Break-rod supplied (use is optional)
  • Models are available with single or double action (breakglass or push) operation
  • UL listed to Standard 38
  • NEMA 1 rated. See Addressable manual station product selection for more information.
Compatible with the following Simplex control panels:
  • Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, 4100U, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications
  • Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications
Compact construction:
  • Electronics module enclosure minimizes dust infiltration
  • Allows mounting in standard electrical boxes
  • Screw terminals for wiring connections
Tamper resistant reset key lock, keyed same as Simplex fire alarm cabinets. Multiple mounting options:
  • Surface or semi-flush with standard boxes or matching Simplex boxes
  • Flush mount adapter kit
  • Adapters are available for retrofitting to commonly available existing boxes
Description

The Simplex addressable manual station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (IAM) constantly monitors status and communicates changes to the connected control panel through IDNet or MAPNET II communications wiring.

Operation

Activation of the 4099-9004 single action manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod which is visible below the pull lever, use is optional. The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication.

Single Action NO GRIP Station 4099-9021. For applications such as California Building Code, Title 24, which requires "Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist" the model 4099-9021 station provides a more easily operated pull lever compared to standard stations. Retrofit of existing stations is available using the 4099-9805 Retrofit kit.

Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station.

Double Action Stations (Push Type) require that a spring loaded interference plate, marked PUSH, be pushed back to access the pull lever of the single action station.

Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. If you use the break-rod, you must replace it.

Station testing is performed by physical activation of the pull lever. You can also perform electrical testing by unlocking the station housing to activate the alarm switch.

Specification
Power and communicationsIDNet or MAPNET II communications, 1 address for each station
Address meansDIP switch, 8 position
Wire connectionsScrew terminal for in/out wiring, for 18 AWG to 14 AWG wire (0.82 mm to 2.08 mm )
UL listed temperature range32°F to 120°F (0°C to 49°C) intended for indoor operation
Humidity rangeUp to 93% RH at 100°F (38°C)
Housing colorRed with white raised lettering
MaterialHousing and pull lever are Lexan polycarbonate or equal
Pull lever colorWhite with red raised lettering
Housing dimensions5 in. H x 3 3/4 in. W x 1 in. D (127 mm x 95 mm x 25 mm)

 Info/Quote Request
 Reseller & Volume Discounts
 Shipping Rates

B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer and Check

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> CALL POINTS :    47 Items found.
BExCP3B-PT-ST-NL-RD-06
(5138)

E2S  BExCP3B-PT-ST-NL-RD-06

E2S BExCP3B-PT Push Button Manual Call Point (Tool resettable) for alarm systems in Zones 1, 2, 21 & 22. B type (choose of end of line devices). LM6 aluminium enclosure. 470R 24Vdc. IP66. ATEX, IECEx, Inmetro and GOST-R certified.

BGWNNNNN100DSNNN7R
(4159)

MEDC  BGWNNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Weatherproof and dust proof only (Uncertified). IP66 & IP67. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$477.46 
BGIBNNNN100DSNNN7R
(4157)

MEDC  BGIBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exia (Intrinsically Safe). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD. GOST R, CQST and Inmetro approvals also available.

Configure

$494.64 
GNEXCP6B-PB-SNSNRD06
(6444)

E2S  GNEXCP6B-PB-SNSNRD06

E2S GNExCP6B-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

GNEXCP6A-PB-SNNRD
(4087)

E2S  GNEXCP6A-PB-SNNRD

E2S GNExCP6A-PB Push Button Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6A-PT-SNNRD
(4088)

E2S  GNEXCP6A-PT-SNNRD

E2S GNExCP6A-PT Push Button Manual Call Point (Tool resettable) for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. GRP Housing. 250VAC or 50VDC. IP66. ATEX and IECEx certified.

GNEXCP6B-PT-SNSNRD06
(6445)

E2S  GNEXCP6B-PT-SNSNRD06

E2S GNExCP6B-PT Tool Reset Manual Call Point for the control of fire and gas alarm systems in Zones 1, 2, 21 & 22. For end of line devices. GRP Housing. IP66. ATEX and IECEx certified.

PBUWNNNN0DSNNN7R
(4212)

MEDC  PBUWNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof only version. Designed for use in hazardous locations and harsh environmental conditions.

Configure

$541.92 
PBIBNNNN0DSNNN7R
(4209)

MEDC  PBIBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 1GD, Ex ia IIC T4 Ga, Ex ia IIIC T135C Da. CUTR, Inmetro and CQST certifications also available.

Configure

$559.15 
BGEBNNNN100DSNNN7R
(1573)

MEDC  BGEBNNNN100DSNNN7R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected Exed (Increased Safety). Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2G. GOST R, CQST and Inmetro approvals also available.

Configure

$615.05 
BGULNNNN100DSNNN6R
(4158)

MEDC  BGULNNNN100DSNNN6R

MEDC BG Manual call point with polyester enclosure and breakglass. Explosion Protected. Designed for use in hazardous locations and harsh environmental conditions. NEMA 4X and 6. UL approved for Class I, Div 2 and Class II, Div 2 Groups A, B, C and D. Weatherproof only version (for Ordinary Locations) also available.

Configure

$670.91 
PBULNNNN0DSNNN7R
(4211)

MEDC  PBULNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. UL Listed for Class 1, Div 2, Groups A,B,C,D, Class II, Div 2, Groups F & G.

Configure

$679.51 
PBICNNNN0DSNNF7R
(4210)

MEDC  PBICNNNN0DSNNF7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. CSA Certified, Class 1, Groups A,B,C,D

Configure

$683.83 
PBEBNNNN0DSNNN7R
(1574)

MEDC  PBEBNNNN0DSNNN7R

MEDC PB Manual call point with polyester enclosure and pushbutton. Weatherproof PB Range. Designed for use in hazardous locations and harsh environmental conditions. ATEX approved Ex II 2GD. EExed IIC T6 (T4 if resistors fitted). CUTR, Inmetro and CQST certifications also available.

Configure

$692.54 
D1XCP1PSDXSNNRD
(6407)

E2S  D1XCP1PSDXSNNRD

E2S D1xCP1-PS Explosion Proof Manual Alarm Pull Station for use in harsh operating environments and hazardous locations. NEMA 4X cast aluminium housing. DPDT switch. UL and FM listed.



 
XAL-53
(6225)

NOTIFIER  XAL-53

Notifier XAL-53 Explosion Proof / Weather Proof Pull Station with Ring. Copper Free Aluminum Enclosure and 3/4" NPT conduits. Suitable for Class I Div 1, Class II Div 1 & 2 and Class III on Hazardous Locations. NEMA 7. UL and CSA Approvals.



 
SM87PBLAI_NNNNNNNNNR
(4219)

MEDC  SM87PBLAINNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,230.09 
SM87PBLAULNNNNNNN_N_N_R
(4220)

MEDC  SM87PBLAULNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Intrinsically Safe (Exia), Exd, Weatherproof. Push Button Latching Key Reset version. Designed for the most harduous environmental conditions. UL Listed: Class 1, Div 1 Groups C & D. UCL version also available.

Configure

$1,294.65 
SM87PBLAD_NNNNNNNNNR
(1575)

MEDC  SM87PBLADNNNNNNNNNR

MEDC SM87PB Manual call point with pushbutton. Exd, Weatherproof. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 2 GD, Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db. CSA, CUTR, IECEx and Inmetro versions also available.

Configure

$1,346.25 
SM87_BGLAI_NNNNNNNNNR
(4192)

MEDC  SM87BGLAINNNNNNNNNR

MEDC SM87BG Manual call point with breakglass. Designed for the most harduous environmental conditions. ATEX Certified, Ex II 1G, Ex ia IIC T4 Ga. CSA (Class I Groups A-D), CUTR, IECEx, Inmetro and CQST versions also available.

Configure

$1,359.12 
Page: 1 | 2 | 3 | All
Cookie Notice

This online store uses cookies to remember users, enable checkout and to collect aggregate information that allows us to analyze traffic patterns on our site (no personal information is stored). For more information you can read our Privacy Policy.