Gasdetectorsusa.com:gas Leak And Flame Detectors, Analyzers, Alarm Devices And Calibration Gas
Gas Leak and Flame Detectors, Analyzers, Alarm Devices and Calibration Gas
TOXIC:    117 Items found.
(376)

GDS  C2-20-029-05/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Nitrogen Dioxide (NO2) sensor with range 0-20 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(366)

GDS  C2-22-012-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Chlorine (Cl2) sensor with range 0-5 to 0-50 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(374)

GDS  C2-22-020-02/00-000-00/0-0-0-0-0/0-0

GDS C2 2-Channel Gas Detector Integral Alarm Controller with local sensor head with integrated Ammonia (NH3) sensor with range 0-50 to 0-1000 ppm with standard 2x 5A SPDT relays, with optional visual-audible alarm, in standard CSA approved, Class I, Division 2 - NEMA 4X non-metallic enclosure 120 VAC, ready to use. With second channel available for optional sensor for EC/Toxic, catalytic, IR or PID sensors.Pushbutton Zero and Span calibration for direct sensors.



 
(5973)

GDS  C2-WWT-1-1-0-1

GDS C2-WWT Triple Gas Sample Draw Gas Monitor for waste water gases in Ambient Air, Hydrogen Sulfide (H2S), Oxygen (O2) and Methane/Propane LEL. Integrated Sample Draw Pump and Flow Monitor Circuitry. Includes red and amber LED strobes and 8 programmable 5A relays. Optional MODBUS TCP interface. Optional toxic sensors: Chlorine (Cl2), Carbon Monoxide (CO) and Sulfur Dioxide (SO2). *** phased out ***



 
(1351)

CHLORGUARD  CG-D-2

ChlorGuard emergency valve shutoff system for CHLORINE (or other toxic/dangerous gas) storage drums. Includes: ChlorGuard 2-Drum Control Panel, Tools Kit, Pneumatic Airdrive Assembly and one remote emergency shutdown button.

(6900)

INTEC  DGC6-A-00-0000US

Intec Controls PolyGard 2 DGC6 Multi-Point Digital Gas Detection and Control System for up to 96 sensors (toxic, combustible and refrigerant gases). Single or Multi-zone applications. Wall Mounted. 4 x 4 to 20mA inputs, 4 alarm relays, 4 digital inputs, up to 16 analog outputs (binary, 4-20 mA) and up to 32 alarm relays, and/or optional BACnet-IP and/or Modbus-RTU port. LCD Display. 120 VAC. NEMA 4X enclosure. IP65. UL Listed. *** Phased Out ***



 
(7194)

MACURCO  GBC-24-2

Macurco Gas Boiler 2-Channel Emergency Shutdown Controller to Interlock/Shutdown up to 8 boilers in the presence of different gases. Includes up to 8 SPDT Interlock/Emergency Shutdown Relays, green power light, a red alarm light, a boiler reset button and an audible buzzer. 24V or 120V. NEMA 4X (IP66) Enclosure. Compatible with Macurco GD-6, CM-6, TX-6-XX, CD-6, CX-6, OX-6 (24VDC with alarm relay) gas detectors.

Configure

$748.13 
(5024)

SIMTRONICS  GD1-L0P-31KH-0XH-A3

SIMTRONICS Alignment Kit for GD1 Toxic Open Path gas detector, includes laser pointer, alignment interface unit (AIU), safety glasses and other accessories.



 
(596)

GDS  GDS-49-REMOTE TRANSMITTER

GDS GDS-49 single channel loop-powered (two-wire) sensor transmitter for toxic / oxygen deficiency applications. Two-wire, non-polarized 4-20mA output. Field-replaceable sensor module. Easily interfaced to all GDS Corp controllers with analog inputs.



 
(1861)

GDS  GDS-SMII-1/000-000-000-000/0-0/1-0

GDS SiteMAX II Rapid Deployment 4-Channel Gas Detection System for Toxic or Combustible Gases, wired or wireless. Optional strobe light and sounder for maximum attention. Includes Large LCD display. 24 VDC or 117/240VAC. NEMA 4x approved for Class 1 Div 2.



 
(1654)

GDS  GMII-01-010-04/01-070-00/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head for Toxic Gases and second channel with backlit LCD display and local stainless steel sensor head for IR (Combustibles/CO2-Carbon Dioxide) or Catalytic Bead sensors, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Available electrochemical sensors for: Oxygen (O2), Carbon Monoxide (CO), Hydrogen (H2), Hydrogen Sulfide (H2S), Hydrogen Cyanide (HCN), Ethylene Oxide (C2H4O), Arsine (AsH3), Silane (SiH4), Hydrazine (N2H4), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Mercaptan (TBM), Tetrahydrothiophene (THT) and Diborane (B2H6)



 
(220)

GDS  GMII-01-011-06/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Carbon Monoxide (CO) with range 0-300/0-1000 ppm (included).



 
(224)

GDS  GMII-01-015-04/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen Sulfide (H2S) with range 0-50/0-100 ppm (included).



 
(225)

GDS  GMII-01-016-12/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Hydrogen Cyanide (HCN) with range 0-50 ppm (included).



 
(228)

GDS  GMII-01-019-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Sulfur Dioxide (SO2) with range 0-20/0-100 ppm (included).



 
(231)

GDS  GMII-01-022-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head configured for Ethylene Oxide ETO (C2H4O) with range 0-20 ppm (included).



 
(6591)

GDS  GMII-01-15-06/01-050-06/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor heads for smartIR (Infrared) sensor with range combustible 0-100% LEL (Lower Explosive Limit) and Toxic Hydrogen Sulfide (H2S), 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Wide selection of hydrocarbons and combustibles: Methane (Natural Gas), Ethane, Propane, Butane, Ethylene, Hydrogen, Pentane, Hexane, IPA, Methanol, MEK and others. CSA Certified for Class I, Div 1.



 
(5821)

GDS  GMII-01-15-06/01-070-06/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor heads for Catalytic Bead sensor with range combustible 0-100% LEL (Lower Explosive Limit) and Toxic Hydrogen Sulfide (H2S), 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Wide selection of hydrocarbons and combustibles: Methane (Natural Gas), Ethane, Propane, Butane, Ethylene, Hydrogen, Pentane, Hexane, IPA, Methanol, MEK and others. CSA Certified for Class I, Div 1.



 
(221)

GDS  GMII-03-012-02/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with local aluminun sensor head configured for Chlorine (Cl2) with range 0-5/0-50 ppm (included).



 
(222)

GDS  GMII-03-013-01/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Chlorine Dioxide (ClO2) with range 0-1 ppm (included).



 
Page: 1 | 2 | 3 | 4 | 5 | 6 | All