(226)

GDS  GMII-03-017-12/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Hydrogen Chloride (HCL) with range 0-30 ppm (included).



 
(227)

GDS  GMII-03-018-02/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Hydrogen Fluoride (HF) with range 0-10 ppm (included).



 
(229)

GDS  GMII-03-020-05/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ammonia (NH3) with range 0-100 ppm (included).



 
(230)

GDS  GMII-03-021-01/01-061-05/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head configured Photoionization Detector for VOC with range 0-20 ppm (low VOC)/0-2000 ppm (high VOC), 4-20 mA output transmitter and Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Second channel with backlit LCD display and local stainless steel sensor head (non-XP) configured for Ozone (O3) with range 0-1 ppm (included).



 
(1655)

GDS  GMII-03-029-05/01-070-00/0-0

GDS GASMAX II 3-Wire Gas Detector with backlit LCD display and local stainless steel sensor head for Reactive Toxic Gases and second channel with backlit LCD display and local stainless steel sensor head for IR (Combustibles/CO2-Carbon Dioxide) or Catalytic Bead sensors, 4-20 mA output transmitter with optional Alarm Relay Board (3x 5A SPDT) and RS-485 Modbus RTU. Available electrochemical sensors for: Sulfur Dioxide (SO2), Chlorine (CL2), Chlorine Dioxide (ClO2), Hydrogen Chloride (HCl), Hydrogen Fluoride (HF), Ammonia (NH3), Ozone (O3), Flourine (F2) and Phosgene (COCL2)



 
(3543)

INTEC  MGC3-02-200

Intec Controls PolyGard MGC3 Two Channel Gas Controller to detect and control levels of toxic and combustible gases. Wall Mounted. Highly configurable. 2 external 4-20mA analog sensors, 1 binary input, 2 alarm relays, 2 open collector outputs and 1 analog output. LCD Display and 4 pushbuttons for configuration. NEMA 4X (IP65) enclosure. UL Certified. *** Phased Out ***



 
(6336)

MPOWER  MPA1-210000-00000

mPower POLI MP400P 5-gas multi-gas detector for toxic gases, optional Oxygen (O2) 0-30% Vol, combustibles (LEL) 0-100%, Carbon Dioxide (CO2) 0-50000ppm, CO2, SO2, combustibles IR, NO, NO2, Cl2, ClO2, HCl, HCN, NH3, PH3, HF, H2, EtO, CH3SH, THT, COCl2, AsH3 and volatile organic compounds (VOCs) 0-2000ppm on hazardous locations. Diffusion or Built-in pump. Audible (90dB0), Visual (flashing LEDs), Vibration and Man-Down alarms. Includes rechargeable Li-ion battery and event logger. IP67. ATEX and UL approved for Class I, Div 1.

Configure

$480.00 
(6470)

INDUSTRIAL SCIENTIFIC  MX6-00000301

Industrial Scientific MX6 iBrid Multi Gas Detector for up to 6 gases. Detects Oxygen (O2), toxic gases, combustible gases (LEL) and volatile organic compounds (VOCs). Catalitic Bead, Electrochemical, Infrared or PID sensors. Includes Full-color LCD Display and 95dB audible alarm. Concussion-proof overmold. IP64. ATEX, CSA, IECEx, UL & INMETRO Approvals.

(6902)

SPECTREX  QRU-C-111

SPECTREX SafEye Quasar 950 open path replacement receiver with ultraviolet technology to detect toxic Hydrogen Sulfide (H2S) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$15,555.90 
(6983)

SPECTREX  QRU-C-211

SPECTREX SafEye Quasar 960 open path replacement receiver with ultraviolet technology to detect toxic Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$13,054.99 
(6901)

SPECTREX  QTU-C-111

SPECTREX SafEye Quasar 950/960 open path replacement transmitter with ultraviolet technology to detect toxic Hydrogen Sulfide (H2S) and Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$14,287.57 
(6855)

SPECTREX  QTU-QRU-C-111

SPECTREX SafEye Quasar 950 open path gas detector and source with ultraviolet technology to detect toxic Hydrogen Sulfide (H2S) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$29,843.47 
(6984)

SPECTREX  QTU-QRU-C-2111

SPECTREX SafEye Quasar 960 open path gas detector and source with ultraviolet technology to detect toxic Ammonia (NH3) at very low concentrations. Long range and high speed response. 24 Vdc. 0-20 mA, HART and RS-485 Modbus outputs. Stainless steel housing. IP66 and IP68. NEMA 250 6P. FM, ATEX, IECEx, CSA and SIL2 approvals.

Configure

$27,342.56 
(3276)

HONEYWELL  S3KUL2

Honeywell Series 3000 MkII Transmitter, with aluminum alloy LM25 housing (optional stainless steel) without sensor for Toxic/Oxygen gases 2-wire 4-20mA loop. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$995.22 
(4457)

HONEYWELL  S3KUL3

Honeywell Series 3000 MkIII Transmitter, intrinsically safe, with aluminum alloy LM25 housing (optional stainless steel) without sensor for Toxic/Oxygen gases 2-wire 4-20mA loop. Available Approvals UL Class I, Div 1 & 2, ATEX Zone 0 and IECEx.

Configure

$1,062.27 
(6764)

PROSENSE  S-DP4

Prosense S-DP4 Gas Detector Controller, Alarm Panel for Up to 4 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$772.20 
(6765)

PROSENSE  S-DP8

Prosense S-DP8 Gas Detector Controller, Alarm Panel for Up to 8 Analog 4-20 mA gas detectors. Monitors explosive (LEL) and toxic(ppm, %VOL), Alarm and Fault LED indicators for each detector and buzzer. Fault, Alarm1, Alarm2 and AUX Relays. Optional Modbus RS485 output and Alarm/Fault Relays for each channel. Polycarbonate Housing, IP66

Configure

$900.90 
(4374)

GDS  SP-12

GDS SP-12 solar power system, 12 watts (1.0A) of DC power for up to 5 days of low sun conditions, or 5 watts for up to 10 days of low sun conditions. Includes 150W solar panel, battery enclosure with pre wired electronic charge controller, two 84AH gelled electrolyte batteries, non rated circuit breakers, cable assembly and mounting hardware. Recommended to power GDS-58XP, GDS-68XP, C2 Protector or C2 Quad Protector with warning strobe and local or remote toxic or combustible sensors.

(4379)

GDS  SP-15

GDS SP-15 solar power system, 15 watts (1.25A) of DC power for up to 5 days of low sun conditions, or 12 watts for up to 7 days of low sun conditions. Includes two 150W solar panels, battery enclosure with pre wired electronic charge controller, two 108AH gelled electrolyte batteries, non rated circuit breakers, cable assembly and mounting hardware. Recommended to power GDS-58XP, GDS-68XP, C2 Protector or C2 Quad Protector with warning strobe and local or remote toxic or combustible sensors.

(4372)

GDS  SP-5

GDS SP-5 solar power system, 5 watts (430mA) of DC power for up to 5 days of low sun conditions, or 3 watts for up to 7 days of low sun conditions. Includes 80Wsolar panel, battery enclosure with pre wired electronic charge controller, 99AH gelled electrolyte battery, non rated circuit breakers, cable assembly and mounting hardware. Recommended to power GDS-58XP, GDS-68XP, C2 Protector or C2 Quad Protector with warning strobe and local or remote toxic or combustible sensors.